Component Atlas

Wearable Biosensors & Monitoring

Skin contact adhesives, flex circuits, microneedle arrays, and BLE modules.

18 categories  |  Component Atlas › Wearable Biosensors & Monitoring

  • How can we improve? — not open yet
☰ Jump to Component (18) ▾

Skin Interface & Sensing

Flexible Electronics & Signal

Protective Enclosure

Component Catalog & Supplier Offerings

Click any component in the visual grid above to jump to its engineering specifications and listed suppliers below. Click any supplier row for its stated focus, the evidence behind its rating, and one-click RFQ formulation.

Listed from public sources. Not contacted or endorsed by 10xAnd. Evidence ratings count checks against public sources — how they work.

Medical Skin Adhesives

↑ Grid
Key Specs: wear time, MVTR, peel force

Breathable hydrocolloid and gentle-release silicone adhesives securing wearable monitors to skin for 7–14 days.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Biosensing Electrodes

↑ Grid
Key Specs: Ag/AgCl, impedance, active area

Screen-printed electrochemical and conductive gel electrode arrays for continuous physiological and biochemical sensing.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Continuous Sensing Microneedles

↑ Grid
Key Specs: micro-pillar height, electrochemical, ISF

Silicon or polymer micro-pillar arrays penetrating the stratum corneum to access dermal interstitial fluid for pain-free continuous analyte tracking.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Solid Electrolyte Hydrogels

↑ Grid
Key Specs: skin impedance, biocompatible, residue-free

Ionic polymer hydrogel sheets providing low-impedance electrical interface between skin and biopotential recording electrodes.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Medical Snap Studs & Eyelets

↑ Grid
Key Specs: nickel-plated brass, Ag/AgCl post, DIN 4mm snap

Standardized circular metal snap studs staked through electrode substrates providing quick mechanical and electrical mating to patient cable leads.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Continuous Glucose Monitoring Sensors

↑ Grid
Key Specs: platinum wire working electrode, GOx enzyme, semipermeable coat

Subcutaneous flexible sensor filaments carrying immobilized glucose oxidase enzyme and mass-transfer limiting polyurethane membranes for continuous interstitial monitoring.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Medical-Grade Closed-Cell Foam Tapes

↑ Grid
Key Specs: polyethylene foam, breathable acrylic adhesive, ISO 10993

Conformable, water-resistant polyethylene and polyurethane foam tapes coated with hypoallergenic pressure-sensitive adhesives for multi-day wearable attachment.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Flexible Sensor Circuits

↑ Grid
Key Specs: layers, line/space, gold finish

Polyimide flexible printed circuits (FPC) routing signals between sensors, batteries, and BLE wireless processors.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Cables

↑ Grid
Key Specs: conductors, shield, jacket

Multi-conductor assemblies. Conductor count and gauge set the electrical job; the jacket and shield usually get chosen by what the cable has to survive rather than what it has to carry.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Kinetic Energy Harvesting Films

↑ Grid
Key Specs: PVDF membrane, voltage output, flexible

Flexible piezoelectric fluoropolymer films converting body movement, heartbeat, or diaphragm motions into electrical battery charging current.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Serpentine Stretchable Interconnects

↑ Grid
Key Specs: screen-printed conductive silver-TPU, 50% elongation

Meander-patterned conductive elastomer and silver traces laminated onto elastic polyurethane films to accommodate body contours and skin deformation.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Dual-Wavelength SpO2 Optical Emitters

↑ Grid
Key Specs: 660nm Red / 940nm IR LEDs, silicon PIN photodiode

Matched optoelectronic emitter and detector assemblies mounted in silicone finger clips or adhesive wraps for non-invasive blood oxygen saturation telemetry.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

PVDF Arterial Waveform Film Sensors

↑ Grid
Key Specs: polarized polyvinylidene fluoride, high d33 coefficient

Piezoelectric polymer thin films mounted over peripheral arteries to measure continuous blood pressure waveforms and arterial stiffness non-invasively.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Seals & O-Rings

↑ Grid
Key Specs: ID, wall, material

Elastomeric seals. ID versus OD versus wall is the classic ordering mistake, which is why they carry glyphs.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Machined Components

↑ Grid
Key Specs: material, tolerance

Turned and milled parts — the general class that covers most reusable-instrument hardware.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Oleophobic Acoustic Vents

↑ Grid
Key Specs: IP68, ePTFE membrane, acoustic transmission loss

Microporous ePTFE membranes protecting internal sensors, microphones, and barometric transducers from moisture and body sweat.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Coin-Cell Leaf Spring Contacts

↑ Grid
Key Specs: gold-plated beryllium copper, high fatigue, CR2032 fit

Stamped BeCu or phosphor bronze spring terminals delivering stable electrical contact to coin cells despite continuous patient vibration and motion.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Moisture-Vapor Permeable TPU Films

↑ Grid
Key Specs: monolithic barrier, MVTR >3000g/m²/day, liquid viral proof

Thin thermoplastic polyurethane barrier membranes that allow skin perspiration to evaporate while barring liquid water, bacteria, and viral pathogens.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.