Hermetic Enclosures & Cans

↑ Grid
Key Specs: Grade 1/2 Ti, wall, laser flange

Deep-drawn Grade 1/2 titanium shells laser-welded into hermetic enclosures for active implant electronics.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Hermetic Feedthroughs

↑ Grid
Key Specs: pins, pitch, leak rate

Multi-terminal platinum and gold brazed ceramic-to-metal feedthroughs delivering electrical signals across hermetic barriers.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Implantable Battery Cells

↑ Grid
Key Specs: capacity, chemistry, lifespan

Primary Li/CFx and secondary lithium-ion cells engineered for 10+ year longevity in active implantable medical devices.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Sapphire Telemetry Windows

↑ Grid
Key Specs: braze alloy, optical transmission, burst

Gold-brazed single-crystal sapphire feedthrough windows providing high optical and RF transparency through titanium implant shells.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

MRI EMI Filter Arrays

↑ Grid
Key Specs: attenuation, capacitance, 1.5T/3T

Integrated discoidal multi-channel ceramic feedthrough capacitors protecting implant circuitry from MRI radiofrequency induced currents.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Deep-Drawn Titanium Can Halves

↑ Grid
Key Specs: Grade 23 Ti-6Al-4V ELI, 0.3mm wall, laser seam

Precision deep-drawn biocompatible titanium enclosure shells with stepped mating flanges designed for hermetic pulsed Nd:YAG laser seam welding.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Transcutaneous Wireless Charging Coils

↑ Grid
Key Specs: litz wire, ferrite shield, 6.78 MHz resonant

Flat spiral wound Litz wire charging receiver coils backed with flexible sintered ferrite shields for transcutaneous RF/inductive power transfer.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Gold-Nickel Feedthrough Braze Preforms

↑ Grid
Key Specs: 82Au/18Ni eutectic, 950°C vacuum braze, hermetic seal

High-purity gold-nickel alloy stamped washer preforms melted in vacuum furnaces to create leak-tight hermetic seals between alumina insulators and titanium flanges.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Stimulation Leads & Electrodes

↑ Grid
Key Specs: electrodes, pitch, DFT wire

Polyurethane or silicone lead bodies with ring electrode arrays delivering neurostimulation therapy to target tissue.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Core Wires

↑ Grid
Key Specs: material, taper, OD

Ground core wires that set the stiffness profile along the length of a wire or delivery system.

📐 Standard Stock Sizes & Scales

Standard Medical Core Wire Diameters & Taper Lengths

ASTM F2063 (Nitinol) / ASTM A313 (304V Stainless)
Draft RFQ for Selected Size ›
Diameter: 0.014″ (0.356 mm) Alloy: Superelastic Nitinol Target: Coronary angioplasty & neurovascular interventional wires
Toggle Complete Stock Size Table (7 sizes)
Size Dia (in) Dia (mm) Alloy Application Action
0.014″ Nitinol Core (180 cm / 300 cm) 0.0140″ 0.356 Superelastic Nitinol Coronary angioplasty & neurovascular interventional wires RFQ ›
0.014″ 304V Stainless Core (190 cm) 0.0140″ 0.356 304V High-Tensile SS Extra support coronary wires, high tactile feedback RFQ ›
0.018″ Nitinol Core (150 cm / 260 cm) 0.0180″ 0.457 Superelastic Nitinol Peripheral arterial intervention, micro-access RFQ ›
0.018″ 304V Stainless Core (180 cm) 0.0180″ 0.457 304V High-Tensile SS Carotid & renal stent delivery guidewire RFQ ›
0.035″ Nitinol Core (150 cm / 260 cm) 0.0350″ 0.889 Superelastic Nitinol Standard universal diagnostic & catheter exchange RFQ ›
0.035″ 304V Extra Stiff (150 cm / 260 cm) 0.0350″ 0.889 304V Extra Hard Amplatz-style extra-stiff support for EVAR / TAVR delivery RFQ ›
0.038″ 304V Heavy Support (150 cm) 0.0380″ 0.965 304V Spring Temper Abdominal aortic aneurysm (AAA) repair, heavy introducers RFQ ›
Supplier Stated Capabilities & Technical Focus Evidence Procurement

Coils

↑ Grid
Key Specs: wire, pitch, flat/round

Wound reinforcement. Trades braid’s torque transmission for hoop strength and flexibility.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Silicone Lead Anchor Sleeves

↑ Grid
Key Specs: radiopaque, compression groove, durometer

Barium-doped molded medical silicone anchor sleeves sutured to muscle or fascia to prevent pacing and neuromodulation lead migration.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Nitinol Fixation Tines

↑ Grid
Key Specs: superelastic, shape-set, deployment force

Laser-cut shape-set superelastic nitinol holding tines anchoring leadless cardiac pacemakers directly into right ventricular trabeculae.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Silicon Neural Recording Arrays

↑ Grid
Key Specs: Utah/Michigan shank array, IrOx sites, 1024-ch

MEMS micromachined penetrating silicon needle arrays with iridium oxide or conductive polymer micro-electrodes for high-channel brain-computer interfaces.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Steroid / Drug Eluting Lead Collars

↑ Grid
Key Specs: dexamethasone silicone matrix, acute threshold reduction

Molded silicone collars loaded with dexamethasone sodium phosphate positioned proximal to pacing electrodes to suppress acute fibrous tissue formation.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Machined Components

↑ Grid
Key Specs: material, tolerance

Turned and milled parts — the general class that covers most reusable-instrument hardware.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Springs

↑ Grid
Key Specs: rate, free length

Compression and extension springs in instrument actuation.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Seals & O-Rings

↑ Grid
Key Specs: ID, wall, material

Elastomeric seals. ID versus OD versus wall is the classic ordering mistake, which is why they carry glyphs.

Supplier Stated Capabilities & Technical Focus Evidence Procurement

Header Connector Cavity Contacts

↑ Grid
Key Specs: IS-1 / DF-4 standard, canted coil spring, sealing rings

Precision machined and stamped platinum-iridium or MP35N spring contact rings housed inside cast epoxy headers to interconnect implantable leads.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Hermetic Magnetic Reed Switches

↑ Grid
Key Specs: glass-to-metal sealed, dry contact, external magnet trigger

Sub-miniature magnetically actuated reed switches allowing physicians to trigger asynchronous pacemaker modes using an external handheld magnet.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.

Kinetic Biomechanical Energy Harvesters

↑ Grid
Key Specs: PZT bimorph cantilever, motion scavenge, battery life

Hermetically encapsulated piezoelectric cantilevers with tungsten proof masses that convert natural heart or gait motion into electrical charge.

Supplier Stated Capabilities & Technical Focus Evidence Procurement
No suppliers listed for this category yet.