Engineering reference & service provider directory. Browse 150 specialized
medical device development and manufacturing service lines across 6 lifecycle stages,
governing consensus standards, and publicly listed contract manufacturers.
⌕
150 services
10X AI · GEMINI ASSISTANTNo Directory Match
Search with Gemini AI for applicable MedTech services
We did not find an exact match for in our 150 directory categories.
Query Gemini AI (Free Tier) to discover governing consensus standards (ISO, ASTM, IEC), engineering deliverables, and AI-suggested contract providers (unverified).
Google Gemini API Key (Optional):
Free tier keys from Google AI Studio are kept locally in your browser. If unconfigured, our built-in MedTech intelligence engine automatically answers.
Consulting Gemini on medical device engineering specifications...
Explore engineering capabilities, governing consensus standards, typical deliverables, and publicly listed providers below. Click RFQ on any provider row to formulate a structured RFQ packet.
Listed from public sources. Not contacted or endorsed by 10xAnd. Evidence ratings count checks against public sources — how they work.
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as TELEFLEX MEDICAL: FEI 3007134520; Specification Developer, Manufacturer; Athlone Westmeath, IE · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
About Rapid Prototyping & Feasibility Builds (Engineering Primer & Selection Guide)Expand ↓
Prototyping in MedTech is not just 3D printing a shape — it is proving clinical physics before committing to tooling.
Feasibility vs. Verification Builds
Feasibility prototypes test whether a mechanism or shaft architecture functions in an anatomical model. They do not require validated tooling or formal DHF protocols, which is why they turn in days rather than months.
However, once a device enters formal Design Verification (DV), every prototype must be produced under validated processes, documented in the Device Master Record, and built in qualified cleanrooms.
Quick-Turn Sourcing Discipline
The biggest delay in catheter and instrument prototyping is custom polymer extrusion lead time. Choosing off-the-shelf stock sizes for the first iteration saves 3 to 6 weeks of die fabrication.
Contract additive manufacturing for anatomical planning models, custom surgical guides, orthopedic trabecular titanium implants, and end-use biocompatible device housings. Technologies include DMLS/SLM for Ti-6Al-4V ELI and CoCr, SLS/FDM for PEEK-OPTIMA, and high-resolution SLA/DLP for USP Class VI microfluidics and hearing housings.
Governing Consensus Standards
ISO/ASTM 52900 — Terminology and process categories ASTM F3001 — Powder bed fusion for surgical implants ISO 10993-5 — Extract testing for photopolymer/sintered resins
Typical Deliverables
Finished sintered or photopolymer parts with support removal and micro-blasting
HIP (Hot Isostatic Pressing) & vacuum thermal stress relief certs for metal implants
Laser diffraction powder lot analysis and material chemical test certs
Micro-CT or optical CMM dimensional inspection scans
⇌
Off-the-shelf component cross-over:
Looking for standard stock trabecular porous coatings and PEEK cages?
✓Site states ISO 13485 certification— found“3D Systems has world-class, FDA-registered, ISO 13485-certified facilities.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as MEDICAL MODELING - A 3D SYSTEMS COMPANY: FEI 3003142829; Contract Manufacturer, Manufacturer; Littleton, CO · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as PROTO LABS: FEI 3038011210; Contract Manufacturer; Morrisville, NC · FDA record ↗ · site named on company’s own page ↗ · checked 2026-10-20
–Website answers— not checkednetwork error (EAI_AGAIN). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (network error (EAI_AGAIN)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (network error (EAI_AGAIN)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (network error (EAI_AGAIN)). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as Tangible Solutions, Inc. DBA Marle Tangible, Inc.: FEI 3014273501; Contract Manufacturer; Fairborn, OH · FDA record ↗ · checked 2026-10-20
About 3D Printing & Additive Manufacturing (Engineering Primer & Selection Guide)Expand ↓
Metal 3D printing enables bone-integrating trabecular lattices impossible with CNC machining.
Porous Titanium vs Traditional Plasma Spray
Additive manufacturing allows osteointegrative pore sizes (300–600 µm with 60–80% porosity) to be integrated continuously throughout an implant, eliminating the risk of coating delamination associated with plasma spray.
Post-processing is critical: un-sintered powder trapped inside deep pores presents a severe particulate risk. Validated ultrasonic passivation and CT verification are mandatory under FDA guidance.
Contract technical drafting, CAD modeling, and regulatory engineering documentation for medical device components and assemblies. Services include ASME Y14.5 GD&T dimensioning, worst-case and RSS tolerance stack-up analysis, conversion of legacy 2D drawings into parametric 3D models, and compilation of Device Master Record (DMR) drawing packages.
Governing Consensus Standards
ASME Y14.5-2018 — Geometric Dimensioning and Tolerancing (GD&T) ISO 8015 — International fundamental tolerancing principles 21 CFR 820.30 — Design output and Device Master Record requirements
✓Site states ISO 13485 certification— found“Management System (QMS) is certified to ISO 13485:2016.” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
–Site states ISO 13485 certification— not checkedgroup statement does not name the company. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
About Drafting, CAD & DHF Documentation (Engineering Primer & Selection Guide)Expand ↓
In medical manufacturing, an ambiguous drawing is the #1 cause of supplier rework and nonconformance.
GD&T Eliminates Coordinate Tolerancing Traps
Using plus/minus square tolerance zones on round medical features creates uncontrolled corner tolerances that either reject good parts or allow mating components to bind.
True position with Maximum Material Condition (MMC) datum references gives contract machine shops manufacturing leeway while guaranteeing assembly fit.
Ultra-precision machining of biocompatible metals and engineering polymers for surgical instrumentation, implantable anchors, robotic end-effectors, and bone screws. Swiss screw machines (7 to 10 axes), multi-axis milling centers, and wire EDM achieve sub-mil tolerances with in-process optical and CMM inspection.
✓Site states ISO 13485 certification— found“System is certified to ISO 13485:2016 and compliant” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Cadence Inc.: FEI 3009266751; Contract Manufacturer; Staunton, VA · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 and FDA QSR compliant.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Tegra Medical - Franklin, MA: FEI 3002758924; Contract Manufacturer; Franklin, MA · FDA record ↗ · checked 2026-10-20
–Site says it serves medical devices— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as NORMAN NOBLE, INC.: FEI 3002755653; Contract Manufacturer; Highland Heights, OH · FDA record ↗ · checked 2026-10-20
About Precision CNC Machining (Engineering Primer & Selection Guide)Expand ↓
Medical machining differs from aerospace in one key respect: every edge touches living tissue or surgeon gloves.
Burr Control and Edge Breaks
A microscopic burr undetectable to the naked eye can peel a PTFE catheter liner or cause tissue tearing. Medical machine shops use specialized thermal deburring, abrasive flow machining (AFM), and electrochemical deburring (ECD).
Specify min/max corner radii (e.g. 0.002″–0.005″) rather than generic "break all sharp edges" notes.
Femtosecond and fiber laser micromachining of micro-tubing, hypotubes, and sheet materials. Produces flexible catheter joints (spiral pitch, interrupted spiral, puzzle-interlocking, and dovetail patterns), peripheral and coronary stents, micro-filters, and retrieval baskets with zero heat-affected zone (HAZ).
Governing Consensus Standards
ASTM F2063 — Nitinol medical devices & stents ISO 25539 — Stent strut integrity and laser cutting requirements
✓Site says it serves medical devices— found“the forefront of medical device manufacturing for” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “laser cut…” or “laser micromachin…” or “laser machining” or “laser process…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“EN ISO 13485:2016” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as PULSE TECHNOLOGIES, INC.: FEI 3003292403; Contract Manufacturer; Quakertown, PA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH.
what was checked ↗
· checked 2026-10-20
–Site says it serves medical devices— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as NORMAN NOBLE, INC.: FEI 3002755653; Contract Manufacturer; Highland Heights, OH · FDA record ↗ · checked 2026-10-20
About Laser Cutting & Micro-Machining (Engineering Primer & Selection Guide)Expand ↓
Laser cutting turns rigid metal tubing into flexible, torqueable catheter shafts.
Cut Patterns: Spiral vs. Interrupted vs. Interlocking
A continuous spiral cut maximizes flexibility but transmits low torque in reverse rotation.
An interrupted spiral with un-cut backbone beams balances 1:1 torque transmission with controlled bending radius.
Dovetail and puzzle-interlocking cuts prevent wall collapse under severe tension or compression.
Pulsed Nd:YAG and fiber laser micro-welding for medical electronics, active implantable hermetic cans, catheter pull-wire terminations, and pacemakers. Includes seam welding of Grade 1/2 titanium enclosures with helium mass spectrometry leak rates verified down to < 1 × 10⁻⁹ atm·cc/s.
Governing Consensus Standards
ISO 15614-11 — Electron beam & laser beam welding MIL-STD-883 Method 1014 — Helium fine and gross leak test procedures
Typical Deliverables
Helium mass spectrometer leak test certification reports
Weld metallographic cross-section mount, etch, and weld penetration inspection
Tensile pull-to-destruction test records on weld joints
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers) ebtec.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
Option 3Litron
litron.comWebsite did not answer as this company on 2026-10-20
📍 Agawam, MA, USA
Glovebox laser hermetic sealing of titanium medical implant enclosures
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to pacaero.com, which does not name Litron Laboratories & Services) litron.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About Laser Welding & Micro-Joining (Engineering Primer & Selection Guide)Expand ↓
Active implantable electronics must remain bone-dry inside the human body for 10+ years.
Hermeticity and Moisture Limits
Implantable microelectronics will fail if internal moisture exceeds 5,000 ppm. Laser welding is performed inside hermetic argon dry-boxes (< 1 ppm moisture/oxygen).
Welding dissimilar metals (like nitinol to stainless steel) requires specialized interlayers or braze foils to avoid brittle intermetallic phases.
✓Site states ISO 13485 certification— found“ISO 13485 and 14971 Risk Management certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016 – Zeus Company, Inc.” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: SC.
what was checked ↗
· checked 2026-10-20
About Custom Extruded Tubing (Engineering Primer & Selection Guide)Expand ↓
Tolerances in micro-extrusion are measured in tenths of a thousandth of an inch.
Bump & Taper Tubing Applications
Bump extrusion continuously varies the tubing diameter along its length during the pull cycle.
This allows catheter shafts to be thick and stiff proximally for pushability, while tapering down to a soft, thin distal tip without a bonded lap joint.
Contract surface treatment and chemical coating application for medical devices. Capabilities include hydrophilic lubricious coatings for interventional catheter shafts and guidewires (reducing friction >90%), pinhole-free vapor-deposited Parylene (N, C, Parylene HT) for electronic insulation and moisture barriers, antimicrobial surface functionalization, and drug-eluting polymer matrices.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 11 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as DSM Biomedical, Inc.: FEI 1000307073; Manufacturer, Contract Manufacturer; Exton, PA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485 certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
About Medical Coatings & Surface Treatment (Engineering Primer & Selection Guide)Expand ↓
Hydrophilic coatings reduce catheter tracking friction by 95%, but FDA scrutiny on particulates is intense.
The Lubricity vs. Particulate Trade-off
FDA’s 2019 safety communication mandates rigorous particulate testing (USP <788>) for all vascular devices. Excess coating lubricity can cause shedding of polymer flakes into the bloodstream.
A robust coating protocol requires optimized plasma pre-treatment, tightly controlled dip-withdrawal velocity, and monitored UV dosage.
Accredited mechanical and design verification testing for medical devices, implants, and delivery systems. Testing spans tensile pull to failure on joints, hydrostatic burst pressure, simulated anatomical trackability and pushability (in tortuous 2D/3D glass models), kink resistance, torque transmission, flexural fatigue, and durability cycles per ISO 10555, ISO 594/80369, and ASTM standards.
Governing Consensus Standards
ISO 10555-1 — Peak tensile force, burst pressure, leakage ISO 17025 — General requirements for laboratory competence ASTM F2514 — Fatigue and durability validation
Typical Deliverables
Formal Design Verification (DV) test protocols and final reports with statistical confidence (95/95 or 90/90)
Load vs displacement, burst pressure, and torque curve raw data and summary charts
Test fixture drawings and Gage R&R measurement system analysis (MSA)
Certificate of testing signed by ISO 17025 accredited quality engineers
⇌
Off-the-shelf component cross-over:
Compare mechanical trade-offs between braid, coil, and hypotube shaft reinforcements.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
Option 3Medical Device Testing Services (MDTS)
mdt-world.comWebsite did not answer as this company on 2026-10-20
📍 Minnetonka, MN, USA
Catheter testing (ISO 10555), stent fatigue, balloon burst, tensile testing
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) mdt-world.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About Mechanical & Verification Testing (V&V) (Engineering Primer & Selection Guide)Expand ↓
FDA submissions require proving device integrity with 95% confidence and 95% reliability.
Sample Size Discipline: Success Run Theorem
For non-destructive or pass/fail attributes, testing 59 samples with zero failures proves 95/95 reliability.
For variable data (like tensile bond strength in Newtons), normal distribution equations allow smaller sample sizes (15–30 samples) provided tolerance intervals clear specification limits by an adequate safety margin.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “certification services (including ISO 13485 and MDSAP) and”, not counted (qualified: "certification services").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “device manufacturers include ISO 13485 and ISO 9001”, not counted (qualified: "registration and certification for").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, IL.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN, DE.
what was checked ↗
· checked 2026-10-20
About Product Safety & Regulatory Testing (IEC 60601-1) (Engineering Primer & Selection Guide)Expand ↓
Medical electrical safety is about one central concept: Means of Patient Protection (MOPP).
The 2 MOPP Requirement
Any applied part that contacts a patient (like an ultrasound transducer or ablation catheter) must provide 2 MOPP insulation against mains voltage (4,000 VAC dielectric isolation and 8 mm creepage distance).
Pre-compliance testing before your industrial design is frozen prevents disastrous PCB redesigns during formal NRTL certification.
Key Focus: ISO 11607, ASTM F88 seal peel, ASTM F1929 dye penetration, ASTM D4169 transit, aging
Comprehensive sterile barrier system (SBS) validation and transit simulation for medical devices. Services include sealing process validation (IQ, OQ, PQ), seal peel strength testing (ASTM F88), bubble leak integrity (ASTM F2096), dye penetration (ASTM F1929), accelerated and real-time shelf life aging (ASTM F1980), and distribution simulation (ASTM D4169 / ISTA 2A/3A drop, vibration, temperature, and vacuum altitude).
Governing Consensus Standards
ISO 11607-1/2:2019 — Materials, sterile barrier systems, and process validation ASTM F88 — Tensile peel force testing of flexible barrier seals ASTM F1929 — Detecting seal channel leaks down to 50 µm ASTM D4169 — Distribution transit vibration, shock, drop simulation ASTM F1980 — Arrhenius equation shelf-life protocol modeling
Typical Deliverables
ISO 11607 Design Verification and Packaging Qualification Summary Report
Seal peel strength (N/15mm or lbf/in) data and load-extension graphs
Dye penetration and bubble leak non-destructive / destructive test records
Transit simulation post-drop visual and sterile barrier integrity pass/fail results
⇌
Off-the-shelf component cross-over:
Looking for sterile pouches, thermoformed trays, backer cards, and cartons?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
About Packaging Validation & Sterile Barrier Testing (Engineering Primer & Selection Guide)Expand ↓
The packaging around a medical device IS part of the device — it maintains sterility until the point of care.
The Critical Distinction: SBS vs. Protective Packaging
The Sterile Barrier System (the Tyvek pouch or thermoformed tray) keeps microorganisms out.
The protective carton and shipper protect the SBS from crushing and puncturing during transit. Both must be validated together under ISO 11607.
Turnkey contract design and manufacturing services (CDMO) taking medical devices from transfer to commercial volume. Complete operations include cleanroom manual and automated assembly, ultrasonic welding, solvent bonding, leak testing, sterile barrier packaging, and device history record (DHR) management.
Governing Consensus Standards
ISO 13485:2016 — Manufacturing controls, traceability, and supplier evaluation 21 CFR 820 — FDA cGMP compliance and DHR requirements GHTF SG3/N99-10 — Installation, Operational, and Performance Qualification (IQ/OQ/PQ)
Typical Deliverables
Complete Device Master Record (DMR) and Device History Record (DHR) trace packets
Process validation protocols and reports (IQ, OQ, PQ per GHTF guidelines)
Validated packaging sealing and label verification inspection logs
Sterilization coordination and final lot release certificates
⇌
Off-the-shelf component cross-over:
Need to source individual off-the-shelf instrument sub-assemblies, springs, and fittings?
✓Site states ISO 13485 certification— found“Quality Management System (QMS) certified to ISO 13485.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as PHILLIPS-MEDISIZE, LLC: FEI 3004058281; Contract Manufacturer; New Richmond, WI · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Tecomet Inc.: FEI 3001451451; Contract Manufacturer; Wilmington, MA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“Certifications: ISO 13485:2016 Certified; FDA Registered; IMMEX /” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Viant Fremont, Inc: FEI 3003080271; Contract Manufacturer; Fremont, CA · FDA record ↗ · site named on company’s own page ↗ · checked 2026-10-20
About Contract Manufacturing & Assembly (CDMO) (Engineering Primer & Selection Guide)Expand ↓
Transferring a design from the R&D bench to a contract cleanroom is where programs succeed or fail.
Process Validation: IQ, OQ, PQ
IQ verifies equipment is installed correctly and calibrated.
OQ challenges operating parameters at worst-case extremes (high/low heat, pressure, dwell time) to establish process capability (Cpk > 1.33).
PQ proves that multiple production runs consistently yield compliant product under real manufacturing conditions.
Key Focus: ISO 14644 Class 7/8, particle counts, HEPA integrity, airflow smoke studies
Turnkey cleanroom installation, airflow balancing, environmental qualification, and routine compliance testing. Covers hardwall and softwall modular cleanroom design, fan filter unit (FFU) installation, viable and non-viable airborne particle counting, HEPA filter PAO leak testing, and differential pressure mapping per ISO 14644 and EU GMP Annex 1.
Governing Consensus Standards
ISO 14644-1:2015 — Particle concentration limits by cleanroom class ISO 14644-3:2019 — HEPA leak testing, airflow velocity, pressure differentials EU GMP Annex 1 — Grade A to D air classification and monitoring
Typical Deliverables
ISO 14644-1 Cleanroom Classification Certification Report
HEPA / ULPA filter aerosol photometer penetration scan test records
Airflow velocity, air changes per hour (ACPH), and room pressurization mapping
Smoke pattern visualization video documentation for laminar airflow verification
⇌
Off-the-shelf component cross-over:
Explore packaging materials suited for ISO Class 7/8 medical cleanroom packaging.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “family, standards like ISO 13485 and ISO 14698”, not counted (qualified: "standards like").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: GA, CA.
what was checked ↗
· checked 2026-10-20
About Cleanroom Installation & Environmental Qualification (Engineering Primer & Selection Guide)Expand ↓
A cleanroom is not just a room with clean filters — it is an active pressure cascade.
Pressure Cascades Prevent Contamination
Medical assembly cleanrooms maintain positive pressure (+0.05″ w.g. / 12.5 Pa) relative to surrounding gowning and corridor spaces, forcing air outward when doors open.
Viable particulate air and surface sampling (swabs and contact plates) must be paired with non-viable airborne optical particle counts.
Key Focus: EtO (ISO 11135), Radiation (ISO 11137), cycle validation, bioburden, SAL 10⁻⁶
Contract industrial terminal sterilization and validation protocol execution for single-use medical devices and combination products. Services include protocol development, half-cycle / overkill validation, bioburden testing, pyrogen/endotoxin testing (LAL), sterility testing, and sterilant residual analysis (ethylene chlorohydrin / ethylene oxide per ISO 10993-7).
Governing Consensus Standards
ISO 11135:2014 — Validation and routine control of EtO sterilization ISO 11137-1/2:2006 — Requirements and establishing the sterilization dose (VDmax/Method 1) ISO 10993-7 — Allowable limits for EO and ethylene chlorohydrin (ECH)
Typical Deliverables
ISO 11135 (EtO) or ISO 11137 (Radiation) Validation Summary Report
✓Site states ISO 13485 certification— found“544716 UKAS Multisite Certificate for ISO13485:2016 & EN” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Sterigenics US, LLC: FEI 1526534; Contract Sterilizer, Export-Only Manufacturer; Lewis Center, OH · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “registered to the ISO 13485 Quality Standards, and”, not counted (qualified: "adheres").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
About Medical Sterilization Services & Validation (Engineering Primer & Selection Guide)Expand ↓
Terminal sterilization must kill bacteria without degrading polymer bonds or leaving toxic residuals.
Selecting the Sterilization Modality
Ethylene Oxide (EtO) is ideal for heat- and radiation-sensitive polymers, electronics, and multi-lumen catheter shafts. However, it requires gas-permeable packaging (like Tyvek) and aeration cycles to off-gas residuals.
Radiation (Gamma/E-beam) penetrates sealed foil barrier pouches and leaves zero chemical residue, but can embrittle polypropylene or cross-link sensitive biomaterials.
Ultra-precision micro-injection molding and high-cavitation cleanroom molding of medical-grade engineering polymers (PEEK, LCP, polycarbonate, bioresorbables, and cyclic olefin copolymers). Capabilities include sub-milligram micro-components, insert molding of metal pins and mesh, thin-wall cannulae hubs, and optical lens molding.
Governing Consensus Standards
ISO 13485:2016 — Cleanroom molding process validation ASTM D3835 — Capillary rheometer viscosity evaluation for medical resins ISO 14644-1 — ISO Class 7/8 particulate airborne limits
Typical Deliverables
Mold flow simulation and gate freeze scientific molding analysis reports
IQ/OQ/PQ tool qualification documentation and dimensional Cpk capability study (Cpk > 1.33)
First Article Inspection (FAI) with multi-cavity optical coordinate measuring machine (CMM) data
Resin lot certifications and cleanroom particulate lot release logs
⇌
Off-the-shelf component cross-over:
Looking for standard luer locks, y-connectors, and manifolds to eliminate custom mold tooling?
✓Site states ISO 13485 certification— found“operations are certified to ISO 13485 , I” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as ACCUMOLD LLC: FEI 3009627506; Contract Manufacturer; Ankeny, IA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Nolato GW Tucson: FEI 3002949731; Contract Manufacturer; Tucson, AZ · FDA record ↗ · checked 2026-10-20
About Medical Injection Molding & Micro-Molding (Engineering Primer & Selection Guide)Expand ↓
Micro-molding is not traditional injection molding scaled down — physics changes when parts weigh fractions of a drop of water.
Scientific Molding and Thermal Residence Control
Tiny shot sizes risk thermal degradation if molten resin sits in the barrel too long. Dedicated micro-molding machines use sub-millimeter screws and micro-plungers with residence times under 60 seconds.
Cavity pressure transducers inside the tool provide real-time 100% part inspection at the millisecond scale.
Key Focus: shape memory setting, active Af testing (ASTM F2082), electropolishing, vacuum furnace
Contract metallurgical processing, precision shape setting, and heat treating of nickel-titanium (Nitinol) alloys. Services include multi-stage mandrel wrapping, fluidized sand bath and vacuum furnace shape setting, active austenite finish (Af) temperature testing per ASTM F2082, chemical oxide removal, and electropolishing per ASTM F2129 for corrosion resistance.
Governing Consensus Standards
ASTM F2063 — Medical grade nitinol bar, wire, and tubing chemical specs ASTM F2082 — Bend and free recovery active Af testing ASTM F2129 — Cyclic potentiodynamic polarization for vascular devices
Typical Deliverables
Active Af transformation temperature test reports with hysteresis curves
Optical comparator and 3D coordinate inspection records on shape-set geometry
✓Site states ISO 13485 certification— found“ISO 13485: Certified” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Confluent Medical Technologies, Inc: FEI 3007635982; Specification Developer; Fremont, CA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“EN ISO 13485:2016 Certification” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
–Site states ISO 13485 certification— not checkedgroup statement does not name the company. Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as MEMRY CORPORATION: FEI 3004579081; Contract Manufacturer; Bethel, CT · FDA record ↗ · checked 2026-10-20
About Nitinol Processing, Shape Setting & Heat Treating (Engineering Primer & Selection Guide)Expand ↓
Nitinol’s superelastic properties are unlocked only after precise thermal constraint and heat treatment.
Austenite Finish (Af) Temperature Control
For self-expanding stents and delivery mechanisms, the active Af temperature must sit between 25 °C and 32 °C, ensuring the device remains superelastic inside the human body (37 °C) but can be crimped at cold room temperatures.
Heat treating above 500 °C sets the physical geometry, while aging time determines precipitation of Ni4Ti3 phases that tune the transformation temperature.
✓Site states ISO 13485 certification— found“ISO 13485:2016 Medical” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: RI.
what was checked ↗
· checked 2026-10-20
–Site states ISO 13485 certification— not checkedgroup statement does not name the company. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT.
what was checked ↗
· checked 2026-10-20
About Precision Metal Stamping & Micro-Forming (Engineering Primer & Selection Guide)Expand ↓
When surgical instrument components scale into millions of units, progressive stamping beats CNC by an order of magnitude.
Burr Management in Stamped Tissue-Contact Parts
Shearing creates a natural punch rollover, shear band, and breakout burr. For surgical staples and vascular clips, secondary vibratory deburring or electrochemical rounding is mandatory to prevent microscopic tissue lacerations.
Key Focus: custom tube drawing (down to 0.004″ ID), cannula grinding, Huber point, 304/316L
Contract micro-tube redrawing, sink drawing, and custom cannula point grinding for biopsy needles, introducers, surgical cannulae, and fluid delivery devices. Precision automated grinding machines produce standard and specialized needle points including lancet, Huber non-coring, trocar, pencil point, and crown cut geometries.
Governing Consensus Standards
ISO 9626:2016 — Stiffness, break resistance, and corrosion specs ISO 7864 — Puncturing force and lubricant limits ASTM A908 — Dimensional tolerances and wall thickness
Typical Deliverables
Multi-angle optical video measurement reports verifying primary, secondary, and rotation angles
Needle penetration force test curve records (N) through simulated tissue membranes
Passivation (ASTM A967) and chemical cleanliness test verification
Tubing tensile strength and elongation material certs
⇌
Off-the-shelf component cross-over:
Need to review standard gauge dimensions, lumen IDs, and needle bevel angle drawings?
✓Site states ISO 13485 certification— found“company (also ISO 9001/13485 certified ), our manufacturing” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as VITA NEEDLE CO.: FEI 1213680; Contract Manufacturer, Manufacturer; Needham, MA · FDA record ↗ · checked 2026-10-20
✓Site says it serves medical devices— found“parts for the medical device industry, along” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “tube drawing” or “drawn tub…” or “cold drawn” or “tube draw…” or “redraw…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“our certifications, including ISO 9001 and ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“to minimally invasive surgical instruments, high-quality precision” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “tube drawing” or “drawn tub…” or “cold drawn” or “tube draw…” or “redraw…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Precision Tube Drawing & Cannula Fabrication (Engineering Primer & Selection Guide)Expand ↓
Point geometry dictates tissue penetration force and core heel damage.
Non-Coring Huber Points vs. Standard Lancet
A standard lancet point punches an oval coupon out of silicone septums, destroying port seals within dozens of punctures.
A Huber needle bends the heel 90° away from the lumen axis, slicing an elastic slit that self-reseals upon needle withdrawal, enabling 2,000+ punctures without leakage.
Contract reinforcement braiding and micro-coil winding over catheter mandrels and inner liners. Technologies include 8, 16, 32, and 64-carrier braiding machines running round or flat stainless steel (304V) and nitinol wire, and precision coil winders running continuous variable pitch transitions to balance 1:1 torque transmission with kink resistance.
Governing Consensus Standards
ISO 10555-1 — Kink resistance and torsional burst requirements ASTM F138 — Medical grade braid wire chemistry
Typical Deliverables
Microscope picks-per-inch (PPI) count audit verification reports along shaft length
Torque response curve (1:1 distal rotation transmission) test data
Braid angle optical measurement and wire crossover thickness validation
Tensile pull-to-break verification records on wire terminations
⇌
Off-the-shelf component cross-over:
Looking for standard round vs flat wire dimensions and braid angle engineering tables?
✓Site states ISO 13485 certification— found“As an ISO 13485 certified and FDA-registered partner,” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as BIOMERICS: FEI 3008998256; Contract Manufacturer; Salt Lake City, UT · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as TELEFLEX MEDICAL: FEI 3007134520; Specification Developer, Manufacturer; Athlone Westmeath, IE · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: AZ.
what was checked ↗
· checked 2026-10-20
About Catheter Braiding, Coiling & Shaft Reinforcement (Engineering Primer & Selection Guide)Expand ↓
Without reinforcement, a polymer tube kinks the moment it navigates a tortuous vascular arch.
Braid vs. Coil Mechanical Trade-offs
Braiding provides superior torsional stiffness and 1:1 torque transmission from the proximal handle to the distal tip.
Coil reinforcement provides maximum hoop strength and kink resistance in acute bends without sacrificing longitudinal trackability.
Hybrid architectures combine a proximal braid for push/torque with a distal coil for atraumatic flexibility.
Cleanroom contract Liquid Silicone Rubber (LSR) injection molding, transfer compression molding, and multi-shot silicone-to-thermoplastic overmolding. Produces implantable pacing leads, needleless injection septums, duckbill valves, surgical gaskets, and endoscopic seals with high tear strength and biocompatibility.
Governing Consensus Standards
ISO 10993 — Cytotoxicity and systemic toxicity for silicones USP Class VI — Implantable elastomeric resin classification ISO 14644-1 — ISO Class 7/8 silicone molding environments
Typical Deliverables
Durometer hardness (Shore A) and tensile elongation test certs per ASTM D412
Flash inspection records (< 0.002″ max flash on critical sealing surfaces)
✓Site states ISO 13485 certification— found“With our ISO 13485:2016 certification, FDA 21 CFR” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 11 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Trelleborg Sealing Solutions Litchfield: FEI 3004126422; Contract Manufacturer; Litchfield, MN · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MD.
what was checked ↗
· checked 2026-10-20
About Medical Silicone Molding & Liquid Injection (LSR) (Engineering Primer & Selection Guide)Expand ↓
Silicone’s chemical inertness and wide temperature stability make it the premier elastomer in MedTech.
Flash Control in Low-Viscosity LSR
Liquid silicone flows with the viscosity of light oil before crosslinking under heat. Tooling tolerances must be held under 0.0001″ (2.5 µm) at parting lines to prevent flash from migrating onto sealing surfaces.
Key Focus: wire EDM down to 0.0008″ wire, burr-free slots, surgical forceps jaws, hardened alloys
Contract ultra-precision wire electrical discharge machining (EDM) of biocompatible metals. Utilizing fine wire electrodes down to 0.0008″ (20 µm) diameter in dielectric deionized oil/water, wire EDM creates intricate geometric contours, narrow slit widths, and deep aspect ratio features in hardened surgical alloys, Nitinol, and titanium with zero mechanical cutting force.
Governing Consensus Standards
ISO 13485:2016 — Precision machining controls ASTM F899 — Wrought hardened surgical alloys ASTM A967 — Recast layer removal and chemical passivation
Typical Deliverables
High-magnification optical and SEM inspection verifying recast layer removal and burr-free edges
Coordinate Measuring Machine (CMM) true position and feature profile inspection reports
Passivation and chemical etch validation certificates
Raw material lot trace certifications
⇌
Off-the-shelf component cross-over:
Compare wire EDM tolerances vs. high-speed CNC milling for miniature surgical jaws.
✓Site says it serves medical devices— found“how a full-service medical device contract manufacturing” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “edm” or “electrical discharge”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“System is certified to ISO 13485:2016 and compliant” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Cadence Inc.: FEI 3009266751; Contract Manufacturer; Staunton, VA · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 and FDA QSR compliant.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Tegra Medical - Franklin, MA: FEI 3002758924; Contract Manufacturer; Franklin, MA · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About Medical Wire EDM & Micro-Machining (Engineering Primer & Selection Guide)Expand ↓
Wire EDM cuts metals of any hardness with zero cutting tool pressure or mechanical distortion.
Recast Layer Removal (White Layer)
Electrical discharge vaporizes metal, leaving a microscopic re-solidified "white layer" containing micro-cracks and altered metallurgy. In medical implants and surgical cutters, this layer must be removed via chemical acid etching or electropolishing.
Accredited chemical surface finishing, passivation, and electrochemical polishing for stainless steel, titanium, and cobalt-chrome medical components. Processes remove free iron, microscopic burrs, and machining contaminants, stabilizing a passive chromium-rich oxide layer (Cr/Fe ratio > 2.0) that resists pitting corrosion in body fluids and harsh autoclave cycles.
Governing Consensus Standards
ASTM A967 — Nitric and citric acid bath validations ASTM B912 — Electrochemical surface enrichment ASTM F86 — Standard practice for implantable alloys
Typical Deliverables
Copper sulfate, high humidity (ASTM A380), and water immersion corrosion test verification reports
XPS / Auger electron spectroscopy oxide depth profile and Cr/Fe ratio certificates (> 2.0)
✓Site states ISO 13485 certification— found“certificate , ISO 13485: 2016 certificate and AS9100:” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
Option 3Celco Electropolishing
celcoep.comWebsite did not answer as this company on 2026-10-20
📍 Anthony, KS, USA
Electropolishing of stainless medical tubing, orthopedic implants, and precision valve parts
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) celcoep.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: KS.
what was checked ↗
· checked 2026-10-20
About Electropolishing, Passivation & Surface Etching (Engineering Primer & Selection Guide)Expand ↓
Passivation is not a coating — it is the selective chemical removal of iron to let chromium heal itself.
Citric vs. Nitric Acid Passivation
Traditional nitric acid can leach chromium and produces hazardous NOx fumes.
Modern citric acid passivation selectively chelates free iron without attacking chromium, nickel, or base metal, yielding higher Cr/Fe oxide ratios (> 2.5) with lower chemical residue risk.
Direct part marking (DPM) of medical devices, surgical tools, and orthopedic implants for FDA Unique Device Identification (UDI) compliance. Utilizing fiber and ultrashort picosecond laser annealing, the surface iron is oxidized sub-surface to produce high-contrast, black marks that maintain corrosion resistance through 100+ autoclave sterilization cycles without penetrating the passive layer.
Governing Consensus Standards
21 CFR 801.40 — Mandatory direct part marking on reprocessed devices ISO 15223-1 — Standardized labeling and identification symbols ISO/IEC 15415 — DataMatrix grade verification (Grade A/B required)
✓Site says it serves medical devices— found“Is Your Medical Device Sharp Enough?” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “laser mark…” or “laser engrav…” or “laser etch…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 and FDA QSR compliant.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Tegra Medical - Franklin, MA: FEI 3002758924; Contract Manufacturer; Franklin, MA · FDA record ↗ · checked 2026-10-20
–Site says it serves medical devices— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI.
what was checked ↗
· checked 2026-10-20
Option 3Litron
litron.comWebsite did not answer as this company on 2026-10-20
📍 Agawam, MA, USA
Medical laser marking, hermetic laser welding, autoclave-durable UDI marking on surgical tools
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to pacaero.com, which does not name Litron Laboratories & Services) litron.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About Medical Laser Marking & UDI Barcoding (Engineering Primer & Selection Guide)Expand ↓
An improper laser mark creates a microscopic pit that rusts after the very first hospital autoclave cycle.
Anneal Marking vs. Ablation Engraving
Ablative laser engraving burns away the passive oxide layer, exposing raw iron that rusts during steam sterilization.
Dark annealing applies controlled thermal pulses that chemically heat-tint the metal below the surface, preserving the protective passive layer while yielding deep black contrast verified to Grade A per ISO 15415.
Biocompatibility & Toxicological Evaluation (ISO 10993)
Full-scope biological safety evaluation and laboratory testing per ISO 10993 and FDA guidance. Services include authoring Biological Evaluation Plans (BEP), performing in-vitro cytotoxicity (MEM elution / MTT), sensitization (guinea pig maximization), irritation, acute systemic toxicity, hemocompatibility (thrombogenicity/hemolysis), implantation tests, and chemical characterization (GC-MS, LC-MS, ICP-MS per ISO 10993-18) paired with toxicological risk assessment (ISO 10993-17).
Governing Consensus Standards
ISO 10993-1:2018 — Biological evaluation framework ISO 10993-5:2009 — Cell culture extract viability testing ISO 10993-18:2020 — Extractables and leachables (E&L) analytical profiling ISO 10993-17:2023 — Establishing allowable limits for toxicological leachables
Typical Deliverables
Biological Evaluation Plan (BEP) and final Biological Evaluation Report (BER) signed by board-certified toxicologists (DABT)
Analytical E&L chemical characterization profile with analytical evaluation threshold (AET) calculations
In-vitro cytotoxicity cell morphology microscopic images and quantitative viability percentage data
Hemocompatibility and hemolysis percentage reports (< 5% non-hemolytic threshold)
⇌
Off-the-shelf component cross-over:
Need to review raw resin USP Class VI vs ISO 10993 biological evaluation differences?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
About Biocompatibility & Toxicological Evaluation (ISO 10993) (Engineering Primer & Selection Guide)Expand ↓
FDA’s 2020 guidance moved biocompatibility from a check-the-box animal test to a chemical risk assessment.
Chemical Characterization Before Animal Testing
FDA and EU MDR strongly favor chemical characterization (ISO 10993-18 extractables and leachables) paired with a toxicological risk assessment over redundant in-vivo animal testing.
If exhaustive extraction reveals no toxic leachables above the Analytical Evaluation Threshold (AET), subchronic and chronic toxicity studies can often be scientifically waived.
Turnkey human factors engineering (HFE) and clinical usability testing for medical devices, surgical consoles, injection pens, and diagnostic software. Services include User Research, Use-Related Risk Analysis (URRA per ISO 14971), Instructions for Use (IFU) comprehension testing, formative usability studies in simulated clinical environments (OR, ICU, cath-lab, home healthcare), and final summative human factors validation protocols for FDA 510(k)/PMA submissions.
Governing Consensus Standards
IEC 62366-1:2015+A1:2020 — Usability engineering process for medical devices FDA Guidance 2016 — CDRH regulatory expectations for summative testing AAMI HE75 — Design principles for medical device user interfaces
Typical Deliverables
Comprehensive Human Factors Engineering Report (HFER) structured for FDA pre-market review
Use-Related Risk Analysis (URRA) matrix linking critical user tasks to clinical harms
High-definition multi-camera video recordings of simulated use sessions with timestamped task logs
Root-cause use-error analysis and UI design iteration recommendations
✓Site states ISO 13485 certification— found“Benefits of being an ISO 13485 certified company” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, TX.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: AZ.
what was checked ↗
· checked 2026-10-20
Option 3Design Science
designscience.comWebsite did not answer as this company on 2026-10-20
📍 Philadelphia, PA / Munich, Germany
Ethnographic user research, simulated use clinical trials, usability validation for complex devices
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but the pages read name only “design science” and state nothing Design Science is listed for (domain may belong to someone else)) designscience.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedonly “design science” is named, too short or common to identify the company. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredonly “design science” is named, too short or common to identify the company. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedonly “design science” is named, too short or common to identify the company. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: PA, DE.
what was checked ↗
· checked 2026-10-20
About Human Factors Engineering & Usability (IEC 62366) (Engineering Primer & Selection Guide)Expand ↓
FDA does not reject devices because surgeons cannot push a button — they reject devices because of close calls.
Critical Tasks and Use-Error Root Cause
Under FDA guidance, a "critical task" is any user action that, if performed incorrectly or omitted, could cause serious injury or death.
Summative testing requires minimum sample sizes of 15 participants per distinct user group (e.g. 15 surgeons + 15 nurses). Every single use error or close call must have a documented root-cause analysis proving residual risk is acceptable.
Accredited EMC and wireless medical device compliance testing. Covers radiated and conducted emissions, electrostatic discharge (ESD ±8 kV contact / ±15 kV air), electrical fast transient (EFT), surge, magnetic field immunity per IEC 60601-1-2 (4th edition + A1), as well as wireless medical device coexistence evaluations per ANSI C63.27 and AAMI TIR69 for Bluetooth LE, Wi-Fi, and cellular transmitters in harsh hospital RF environments.
Governing Consensus Standards
IEC 60601-1-2:2014+A1:2020 — EMC requirements and immunity levels for medical devices ANSI C63.27:2021 — Testing wireless performance in dense RF environments AAMI TIR69:2017 — Clinical wireless hazard analysis FCC Part 15 / RED Directive — Unintentional and intentional transmitter approvals
Typical Deliverables
Accredited EMC Test Report with frequency spectrum scan graphs (emissions vs. limit lines)
Wireless Coexistence Test Report documenting packet latency and throughput under simulated RF crowding
ESD discharge point map photos and immunity verification logs
FCC / ISED / CE Radio Equipment Directive (RED) certification declaration packages
⇌
Off-the-shelf component cross-over:
Need to review conductive chassis gaskets, ferrite beads, and cable shielding guidelines?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “certification services (including ISO 13485 and MDSAP) and”, not counted (qualified: "certification services").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN.
what was checked ↗
· checked 2026-10-20
About Electromagnetic Compatibility & Wireless Coexistence (EMC) (Engineering Primer & Selection Guide)Expand ↓
A medical device must not interfere with an OR monitor — and must not fail when a phone rings next to it.
IEC 60601-1-2 4th Edition Immunity Rigor
The 4th edition increased proximity magnetic field immunity (up to 30 A/m) and required testing against modern RFID and cellular LTE frequencies up to 28 V/m.
Wireless medical devices (like continuous glucose monitors or surgical drills) must pass ANSI C63.27 coexistence testing to prove safety when adjacent Wi-Fi channels are 100% saturated.
Contract surface-mount technology (SMT) printed circuit board assembly (PCBA) and high-level electromechanical box-build assembly for Class II/III medical devices. Operations include fine-pitch component placement, 3D automated optical inspection (AOI), 3D X-ray inspection of hidden BGA solder joints, conformal coating, wire harness routing, chassis assembly, firmware flashing, and functional test execution.
Governing Consensus Standards
IPC-A-610 Class 3 — High-reliability medical electronics standards ISO 13485:2016 — Electronics contract manufacturing trace controls ANSI/ESD S20.20 — ESD protection for sensitive electronic medical assemblies
Typical Deliverables
IPC-A-610 Class 3 certificate of inspection with 3D AOI and X-ray BGA void analysis images
In-Circuit Test (ICT) and Functional Test (FCT) voltage/current telemetry logs
Device History Record (DHR) serial tracking linking every IC date code to finished serial number
Conformal coating thickness (ASTM D6132) and UV coverage verification reports
⇌
Off-the-shelf component cross-over:
Need to review medical power supplies, LEMO/ODU circular push-pull connectors, and wiring?
✓Site states ISO 13485 certification— found“ISO 13485 (MN, MX, VN)” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as CDR Manufacturing, Inc., DBA Keytronic: FEI 3003857828; Contract Manufacturer; Oakdale, MN · FDA record ↗ · site named on company’s own page ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485 certified medical design centers design and” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Sanmina: FEI 1000161215; Export-Only Manufacturer, Contract Manufacturer; San Jose, CA · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as PLEXUS CORP.: FEI 2183715; Contract Manufacturer; Neenah, WI · FDA record ↗ · checked 2026-10-20
About Electronic Box Build & Medical PCBA Assembly (Engineering Primer & Selection Guide)Expand ↓
In medical electronics, IPC Class 3 is not an option — it is the barrier between a functioning console and a life-support shutdown.
IPC Class 2 vs. IPC Class 3 Solder Standards
Consumer electronics follow IPC Class 2 where minor solder voids and partial barrel fill are acceptable.
Medical devices require IPC Class 3: 75% minimum through-hole barrel fill, zero component overhang, and 100% 3D X-ray inspection of leadless ball grid arrays (BGAs) to prevent latent joint failure under transport vibration.
Chamber-based accelerated thermal aging and real-time stability testing for medical devices, drug-delivery combination products, and sterile packaging systems per ASTM F1980. Uses the Arrhenius reaction rate model ($Q_{10} = 2.0$ at 55 °C or 60 °C) to simulate 1-year, 2-year, 3-year, and 5-year shelf-life expiration dates in weeks, followed by physical functional testing and sterile barrier seal verification.
Governing Consensus Standards
ASTM F1980:2021 — Arrhenius equation shelf-life simulation ISO 11607-1:2019 — Stability testing and sterile barrier maintenance ICH Q1A(R2) — Combination product temperature & humidity protocols
Typical Deliverables
ASTM F1980 Accelerated Aging Calculation Protocol and chamber test schedule report
Continuous calibrated temperature and relative humidity chamber data logger charts
Post-aging tensile bond, burst pressure, and sterile barrier seal strength comparison data
✓Site states ISO 13485 certification— found“Device Contract Packaging - ISO 13485 Certified Services” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CO, MI.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
About Accelerated Aging & Real-Time Shelf Life Testing (Engineering Primer & Selection Guide)Expand ↓
You cannot stamp a 3-year expiration date on a sterile device without proving the sterile barrier holds for 3 years.
The Arrhenius Aging Equation ($Q_{10} = 2.0$)
Under ASTM F1980, the conservative aging factor ($Q_{10}$) is 2.0 — meaning every 10 °C increase in storage temperature doubles the chemical degradation rate.
Aging at 55 °C ($33 \text{ °C}$ above ambient $22 \text{ °C}$) yields an Acceleration Factor ($AAF$) of approximately $2^{3.3} \approx 9.85$, simulating 365 days of shelf life in just 37 days.
FDA requires parallel real-time ambient aging to run alongside accelerated aging until the full labeled shelf-life is reached.
Precision stretch blow molding, thermal necking, folding, and pleating of medical balloons for PTCA, PTA, structural heart, and endovascular delivery. Also includes thermal tip forming, RF tipping, and atraumatic bevel shaping.
Governing Consensus Standards
ISO 10555-4 — Burst pressure, fatigue, and profile verification ASTM F2079 — Rated Burst Pressure (RBP) statistical derivation
✓Site states ISO 13485 certification— found“ISO13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: GB, JP.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485 and 14971 Risk Management certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
About Catheter Balloon Forming & Tip Shaping (Engineering Primer & Selection Guide)Expand ↓
Medical balloon blow molding demands precise temperature control and pre-form expansion ratios to achieve tight rated burst pressure tolerances.
Non-Compliant vs. Semi-Compliant
Non-compliant PET balloons maintain exact diameter up to high pressures (20–30 atm), ideal for calcified lesions and stent deployment.
Semi-compliant Pebax balloons provide gentle anatomical compliance and post-dilation elasticity.
Permanent, particle-free joining of rigid and flexible medical thermoplastics without chemical adhesives. Specialized acoustic horn design, energy directors, and cleanroom acoustic enclosures.
Governing Consensus Standards
ISO 13485 — Process validation (IQ/OQ/PQ) for joint strength ASTM F88 — Tensile and burst strength verification of welded joints
Typical Deliverables
Custom acoustic horn and nest fixture fabrication
Joint design DFM (shear joint, energy director, tongue-and-groove)
Process parameter validation report (amplitude, weld time, trigger force)
Hermetic helium leak and burst pressure test certificates
⇌
Off-the-shelf component cross-over:
Source molded plastic shells and luer fittings for welding.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 11 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “bonding methods in FDA or ISO 13485 environments.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, DE.
what was checked ↗
· checked 2026-10-20
About Ultrasonic & Thermal Plastic Welding (Engineering Primer & Selection Guide)Expand ↓
High-frequency acoustic vibrations convert into frictional heat at designed energy directors, creating molecular fusion without particulates.
Process Validation Rigor
Medical plastic welding requires servo-driven depth control to sub-micron accuracy, eliminating flash and particulate contamination.
Key Focus: rigid/flexible endoscopes, surgical camera heads, laser delivery fibers
Design, micro-assembly, and hermetic packaging of miniature medical optical systems. Includes active 6-axis MTF lens alignment, chip-on-tip CMOS sensor soldering, sapphire window brazing, and autoclavable scope assembly.
Governing Consensus Standards
ISO 8600-1 — Optical resolution, field of view, and distortion IEC 60601-2-18 — Electrical safety and thermal management of light guides
Typical Deliverables
Modulation Transfer Function (MTF) optical test reports
Hermetic helium leak rate test verification (< 1x10^-8 mbar*l/s)
✓Site states ISO 13485 certification— found“FISBA AG → ISO 13485:2016” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CH.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “optic…” or “photonic…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, DE.
what was checked ↗
· checked 2026-10-20
About Medical Optics, Endoscopy & Photonics (Engineering Primer & Selection Guide)Expand ↓
Surgical visualization demands diffraction-limited resolution while surviving repeated steam sterilization cycles without seal failure.
Active Optical Alignment
Sub-micron active alignment ensures modulation transfer function (MTF) meets clinical sharpness across all field angles.
Contract GLP in-vivo testing in accredited animal cath labs for cardiovascular, orthopedic, and surgical devices. Evaluates acute deliverability, chronic vascular remodeling, endothelialization, and safety.
Governing Consensus Standards
21 CFR Part 58 — Quality assurance, study director oversight, raw data archiving ISO 10993-6 — Local tissue tolerance, fibrous capsule formation, histopathology
Typical Deliverables
Comprehensive GLP Study Protocol & Final Safety Report for FDA/Notified Body
Continuous fluoroscopic angiography and intravascular ultrasound (IVUS) recordings
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
About Preclinical Animal Models & GLP In-Vivo Cath Lab (Engineering Primer & Selection Guide)Expand ↓
FDA requires pivotal in-vivo safety and efficacy studies to strictly adhere to 21 CFR Part 58 (GLP) with an independent Quality Assurance Unit.
Acute Deliverability vs. Chronic Healing
Acute studies verify deliverability and tracking, while chronic 30/90/180-day studies evaluate tissue healing and thrombogenicity.
Key Focus: 510(k) authoring, CE mark dossiers, FDA pre-sub meeting preparation
Strategic regulatory consulting for medical devices and IVDs. Services include predicate device identification, Pre-Submission (Q-Sub) briefing packs, eSTAR 510(k) file authoring, PMA modules, and EU MDR 2017/745 Technical Documentation.
Governing Consensus Standards
21 CFR 807 — Substantial equivalence dossiers EU MDR 2017/745 — Annex II & III Technical Documentation & GSPR
Typical Deliverables
Complete FDA eSTAR 510(k) submission package with all technical attachments
FDA Pre-Submission (Q-Sub) briefing document with prioritized strategic questions
EU MDR General Safety and Performance Requirements (GSPR) checklist
Clinical Evaluation Plan (CEP) and Clinical Evaluation Report (CER) compliant with MEDDEV 2.7/1 Rev 4
⇌
Off-the-shelf component cross-over:
Search 510(k) clearance records and identify top predicate devices.
✓Site states ISO 13485 certification— found“Benefits of being an ISO 13485 certified company” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, TX.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “manufacturing compliance (e.g., ISO 13485), MDSAP preparation and”, not counted (qualified: "internal audit").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: DC, NY, WA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “Consulting, auditing, and ISO 13485-compliant QMS designed for”, not counted (qualified: "compliant").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN.
what was checked ↗
· checked 2026-10-20
About Regulatory Affairs Consulting (510k, PMA, CE MDR) (Engineering Primer & Selection Guide)Expand ↓
A sound regulatory strategy aligns product testing with FDA and Notified Body expectations before expensive laboratory verification begins.
The eSTAR Mandate
Since October 2023, all 510(k) submissions must be formatted in FDA’s interactive eSTAR template, requiring exact evidentiary cross-referencing.
Key Focus: IEC 62304 Class B/C software, FDA cybersecurity, automated unit testing
Contract architecture, coding, and verification for medical device software (firmware, controller logic, and Software as a Medical Device). Full compliance with IEC 62304 lifecycle stages, AAMI TIR57 cybersecurity, and FDA guidance.
Governing Consensus Standards
IEC 62304 — Class A, B, C architecture, verification, and maintenance FDA Cybersecurity — SBOM, threat modeling, and post-market patch management
Typical Deliverables
Software Architecture Document (SAD) and Detailed Design Specifications
Software Requirements Specification (SRS) with bidirectional traceability matrix
Threat model analysis and Software Bill of Materials (SBOM) in SPDX format
Automated unit, integration, and system verification test execution logs
⇌
Off-the-shelf component cross-over:
Validate wireless RF software protocols under active interference.
✓Site states ISO 13485 certification— found“System is certified by BSI to ISO 13485:2016.” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL.
what was checked ↗
· checked 2026-10-20
–Site states ISO 13485 certification— not checkedgroup statement does not name the company. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
–Site states ISO 13485 certification— not checkedgroup statement does not name the company. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH.
what was checked ↗
· checked 2026-10-20
About Medical Device Software & SaMD (IEC 62304) (Engineering Primer & Selection Guide)Expand ↓
Medical software requires rigid traceability from clinical hazard analysis down to individual code functions and automated verification test cases.
Class B vs. Class C Rigor
Class C software (where injury or death could occur) mandates detailed unit architecture, 100% statement and branch code coverage, and regression tracking.
Key Focus: Investigational Device Exemption (IDE), patient recruitment, site monitoring
Contract management of early feasibility studies (EFS), pivotal Investigational Device Exemption (IDE) trials, and post-market clinical follow-up (PMCF). Services include protocol design, investigator site selection, IRB filings, and data management.
Governing Consensus Standards
ISO 14155 — Good Clinical Practice (GCP) and ethical conduct 21 CFR 812 — Sponsor obligations, investigator agreements, and adverse event reporting
Typical Deliverables
Clinically sound Investigational Plan & Clinical Study Protocol
Electronic Data Capture (EDC) database built on 21 CFR Part 11 compliant platforms
Clinical site monitoring visit reports (SIV, IMV, COV)
Interim and final Clinical Study Reports (CSR) for FDA PMA/510(k) submissions
⇌
Off-the-shelf component cross-over:
Align clinical endpoints with FDA Q-Sub feedback before study launch.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “Consulting, auditing, and ISO 13485-compliant QMS designed for”, not counted (qualified: "compliant").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN.
what was checked ↗
· checked 2026-10-20
Option 3IQVIA MedTech
iqviamedtech.comWebsite did not answer as this company on 2026-10-20
📍 Durham, NC / Danbury, CT
Global site network, digital patient recruitment, adaptive trial analytics
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers and redirects to iqvia.com) iqviamedtech.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers and redirects to iqvia.com). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers and redirects to iqvia.com). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers and redirects to iqvia.com). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT, NC.
what was checked ↗
· checked 2026-10-20
About Clinical Research Organization (CRO) & IDE Trials (Engineering Primer & Selection Guide)Expand ↓
Unlike pharmaceutical trials, medical device investigations must account for surgical technique, device learning curves, and anatomical variations.
Early Feasibility Studies (EFS)
FDA’s EFS program allows clinical iteration in a small study group under an approved IDE before product design freeze.
Key Focus: hydrophilic lubricity, drug coating, particulate minimization
Application of low-friction hydrophilic coatings to catheter shafts, guidewires, and delivery sheaths, reducing coefficient of friction by >90%. Also includes ultrasonic spray coating of antiproliferative drugs (paclitaxel, sirolimus) onto balloon surfaces.
Governing Consensus Standards
ASTM F2743 — Frictional pinch testing and particulate matter counting ISO 10993-4 — Hemocompatibility and non-thrombogenic surface verification
Typical Deliverables
Pinch-test lubricity profiles (gram-force track resistance over 20+ cycles)
✓Site states ISO 13485 certification— found“regulations and Biocoat is ISO 13485:2016 certified .” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: PA.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO13485 Certified | ISO17025 Accredited” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About Hydrophilic & Drug-Eluting Catheter Dip Coating (Engineering Primer & Selection Guide)Expand ↓
Lubricious coatings allow complex neurovascular and cardiovascular catheters to navigate tortuous vessels with minimal vessel trauma.
Particulate Mitigation
Modern FDA guidance requires rigorous particulate testing to prove coatings do not flake or shed emboli into the bloodstream.
Verification and validation of cleaning instructions for reusable medical instruments and endoscopes. Tests simulated clinical use soiling, automated washer-disinfector cycles, and residual protein/carbohydrate/hemoglobin extraction.
Governing Consensus Standards
AAMI TIR30 — Soil inoculation, extraction endpoints, and analytical methods ISO 17664-1 — Information to be provided by manufacturer for reprocessing
Typical Deliverables
Cleaning Validation Protocol with clinically worst-case soil inoculation schema
Micro BCA protein, micro-bicinchoninic carbohydrate, and hemoglobin residual reports
Defensible Instructions for Use (IFU) validated for hospital CSSD personnel
Visual cleanliness and boroscopic lumen inspection records
⇌
Off-the-shelf component cross-over:
Ensure joint and lumen geometry can be effectively flushed in hospital washers.
✓Site says it serves medical devices— found“advisory services for MedTech and pharmaceutical companies.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “cleaning validation” or “cleaning verification” or “reprocessing” or “cleaning efficacy”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“pharmaceutical, biotech and medical device industries worldwide” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “cleaning validation” or “cleaning verification” or “reprocessing” or “cleaning efficacy”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
Option 3Highpower Validation Laboratories
highpowervals.comWebsite did not answer as this company on 2026-10-20
📍 Rochester, NY
Reusable device reprocessing and steam sterilization validation
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) highpowervals.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NY.
what was checked ↗
· checked 2026-10-20
About Cleaning Validation & Reprocessing (AAMI TIR30) (Engineering Primer & Selection Guide)Expand ↓
FDA requires that every reusable medical device undergo quantitative cleaning validation to ensure hospital reprocessing removes patient soil.
Soil Inoculation & Test Soils
Devices are inoculated with synthetic test soil containing artificial blood, protein, and endotoxin, followed by extraction assays to prove cleanliness.
Contract fabrication of structural sheet metal cabinets, mobile surgical carts, and generator chassis. Capabilities include automated laser punching, precision CNC press brake folding, spot welding, and powder coating.
Governing Consensus Standards
ISO 13485 — Enclosure traceability and dimensional control IEC 60601-1 — Mechanical strength, ingress protection (IP21/IPX4), drop/impact
Typical Deliverables
Complete sheet metal DFM feedback (bend radii, hole-to-edge relief)
First Article Inspection (FAI) CMM dimensional reports
UL 94-V0 rated powder coat finish and salt-spray corrosion certificates
Full chassis sub-assembly with PEM hardware, gaskets, and castor wheels
⇌
Off-the-shelf component cross-over:
Source internal power supplies and cooling fans for your chassis.
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 8 pages read)
what was checked ↗
· checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “sheet metal” or “enclosure…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 8 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: GA, MN.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: WI.
what was checked ↗
· checked 2026-10-20
About Precision Sheet Metal & Console Enclosures (Engineering Primer & Selection Guide)Expand ↓
Medical equipment chassis must withstand hospital cleaning chemicals, prevent fluid ingress, and absorb accidental impact without cracking.
Hospital-Grade Chemical Resistance
Enclosure finishes must withstand aggressive disinfectants like quaternary ammonium compounds and bleach without blistering.
Health economics and market access consulting ensuring innovative medical technologies receive adequate provider payment and payer coverage upon FDA clearance. Covers CPT/HCPCS coding applications, Medicare NCD/LCD coverage, and budget impact models.
Governing Consensus Standards
AMA CPT Process — Category I and Category III CPT code applications CMS Guidelines — Inpatient Prospective Payment (IPPS) & outpatient (OPPS) payment
Typical Deliverables
Comprehensive US & EU Reimbursement Landscape Assessment
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 11 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: DC, WA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “Consulting, auditing, and ISO 13485-compliant QMS designed for”, not counted (qualified: "compliant").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN.
what was checked ↗
· checked 2026-10-20
About Reimbursement Strategy, Coding & Health Economics (Engineering Primer & Selection Guide)Expand ↓
FDA clearance allows you to sell a device; reimbursement determines whether hospitals and physicians will actually buy and adopt it.
The Three Pillars of Reimbursement
Every medical device requires all three pillars: Coding (CPT/HCPCS), Coverage (Medicare/Commercial policy), and Payment (adequate fee schedule).
Contract manufacture of high-reliability medical cable assemblies, sensor harnesses, and surgical handpiece cables. Specializes in low-noise micro-coax, biocompatible silicone overmolding, circular connector soldering, and pull-relief.
Governing Consensus Standards
IPC/WHMA-A-620 — Class 3 High Performance/Harsh Environment criteria IEC 60601-1 — Dielectric withstand voltage, insulation, and patient leakage current
Typical Deliverables
Tooling and overmold cavities for custom connector strain reliefs
100% automated electrical continuity, resistance, and hi-pot test reports
Mechanical pull-test and flex-life cycle qualification (10,000+ bend cycles)
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MX.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “Certifications Include - ISO 13485 2003 Compliant, ISO”, not counted (names ISO 13485:2003, an edition withdrawn in 2019, not a current certificate).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
Option 3Carlisle Interconnect Technologies
carlisleit.comWebsite did not answer as this company on 2026-10-20
📍 St. Augustine, FL / Franklin, WI
Autoclavable surgical cables, RF ablation lead wires, custom connector overmolds
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) carlisleit.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL, WI.
what was checked ↗
· checked 2026-10-20
About Custom Medical Cable Harnesses & Lead Wires (Engineering Primer & Selection Guide)Expand ↓
Surgical cables endure aggressive pulling, rolling bed wheels, chemical cleansers, and autoclaving without signal degradation or dielectric failure.
Flex-Life and Noise Immunity
Micro-coaxial lines with triboelectric noise suppression layers eliminate motion artifacts in sensitive electrophysiology and EEG sensors.
Room-temperature vapor deposition polymerization (VDP) of ultra-thin, pinhole-free polymer films. Provides superior chemical barrier, moisture insulation, and biocompatibility on stents, implantable pacemakers, sensors, and silicone mandrels.
Governing Consensus Standards
USP Class VI — Systemic toxicity, intracutaneous reactivity, muscle implantation ISO 10993 — Cytotoxicity, sensitization, and hemocompatibility
✓Site states ISO 13485 certification— found“ISO 13485 certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
Option 3Diamond-MT
diamond-mt.comWebsite did not answer as this company on 2026-10-20
📍 Johnstown, PA
Rapid-turn Parylene coating for medical electronics, sensors, and stents
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to scscoatings.com, which does not name Diamond-MT) diamond-mt.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: PA.
what was checked ↗
· checked 2026-10-20
About Parylene Conformal Coating & Vapor Deposition (Engineering Primer & Selection Guide)Expand ↓
Applied in a vacuum at room temperature as a gas, Parylene forms a uniform molecular barrier over sharp edges and inside microscopic lumens without meniscus or puddling.
Implantable Barrier Protection
Parylene C creates an impenetrable barrier against corrosive physiological body fluids, protecting active electronics and implantable sensor telemetry.
Key Focus: ISO 13485 certification, FDA QMSR alignment, mock FDA inspections, CAPA remediation
Turnkey implementation and remediation of medical device Quality Management Systems. Aligns startup and mid-size device companies with ISO 13485:2016, MDSAP, and FDA’s new Quality Management System Regulation (QMSR).
Governing Consensus Standards
ISO 13485:2016 — Design controls, risk management integration, supplier quality 21 CFR 820 / QMSR — Harmonized FDA requirements incorporating ISO 13485
Typical Deliverables
Complete, auditor-ready QMS Standard Operating Procedures (SOPs) and form templates
Design Controls & Risk Management framework compliant with ISO 14971:2019
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 certifications”, not counted (a count ("2,000+ ISO 13485 certifications"), not a statement).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “Preparing for Your ISO 13485:2016 Stage 1 Audit”, not counted (the site says it is not (yet) certified).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: GA, MN.
what was checked ↗
· checked 2026-10-20
Option 3Quality Systems Innovations (QSI)
qsiconsulting.comWebsite did not answer as this company on 2026-10-20
📍 Boston, MA / San Diego, CA
FDA 483 / Warning Letter remediation, mock QSIT audits, MDSAP compliance
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers) qsiconsulting.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MA.
what was checked ↗
· checked 2026-10-20
About Quality Management System (QMS & FDA QMSR) (Engineering Primer & Selection Guide)Expand ↓
FDA’s transition to the QMSR officially harmonizes US federal regulations with ISO 13485:2016, emphasizing risk-based quality across all operational stages.
Right-Sized QMS for Startups
A right-sized QMS provides rigorous design controls and traceability without choking pre-clinical engineering speed under bureaucratic paperwork.
Key Focus: electrophysiology ring electrodes, thermocouple crimping, sensor micro-welding
Precision mechanical and metallurgical joining of miniature sensor electrodes onto catheter shafts and guidewires. Capabilities include rotary swaging of Pt-Ir bands, resistance micro-welding of thermocouple junctions, and laser wire stripping.
Governing Consensus Standards
ASTM F562 — Conductor wire mechanical tensile strength ISO 13485 — In-process electrical resistance and mechanical retention validation
Typical Deliverables
Micro-swaging tooling and collets matched to catheter shaft OD tolerances
Mechanical pull-force retention test reports (minimum specified retention in Newtons)
✓Site says it serves medical devices— found“contribution: Production of medical technology such as” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “swag…” or “crimp…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as HERAEUS MEDICAL COMPONENTS, LLC: FEI 3008988055; Specification Developer, Complaint File Establishment, Contract Manufacturer; Saint Paul, MN · FDA record ↗ · checked 2026-10-20
✓Site says it serves medical devices— found“for the World’s Most Complex Medical Devices” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “swag…” or “crimp…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016 Certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
About Electrode Swaging, Micro-Crimp & Sensor Joints (Engineering Primer & Selection Guide)Expand ↓
Electrophysiology mapping and ablation catheters require seamless electrode swaging with flush OD transitions to prevent vascular trauma during heart catheterization.
Electrical and Mechanical Integrity
Micro-crimp joints must maintain low contact impedance under thousands of cardiac flex cycles while ensuring the ring cannot dislodge under tensile loading.
Contract design, CNC tooling, and cleanroom heat sealing of rigid medical blister packaging. Includes thermoforming of biocompatible PETG/HIPS trays, custom seal platen fabrication, and heat sealing parameter validation.
Governing Consensus Standards
ISO 11607-1 — Materials, sterile barrier systems, and packaging systems ASTM F88 — Peel strength verification across platen perimeter
Typical Deliverables
3D packaging CAD models and CNC machined aluminum thermoform molds
Custom matching CNC heat-seal tooling platens and silicone gaskets
Seal parameter process validation report (Temperature, Pressure, Dwell Time)
100% dye penetration leak test reports per ASTM F1929
⇌
Off-the-shelf component cross-over:
Validate your thermoformed blister package under ISO 11607 transit testing.
✓Site states ISO 13485 certification— found“Quality Commitment with ISO 13485 Certification for Phoenix” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Nelipak Healthcare Packaging: FEI 3005581234; Contract Manufacturer; Clara, Offaly, IE · FDA record ↗ · site named on company’s own page ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
About Thermoform Blister Tooling & Heat Sealing (Engineering Primer & Selection Guide)Expand ↓
Rigid thermoformed blister packaging immobilizes sharp surgical implants and delicate catheter hubs, maintaining sterility through transit and presentation in the OR.
Aseptic Presentation
Clean-peel Tyvek lids must separate smoothly without fiber tear, preventing particulate contamination in the surgical field.
Dielectric radiofrequency welding of polar medical films to create hermetic, tear-resistant fluid and pneumatic containment bladders. Includes custom brass die tooling, tube port insert welding, and burst testing.
Governing Consensus Standards
ISO 13485 — Seal repeatability and process parameter monitoring ISO 3826-1 — Tensile seal strength, leakage, and transparency
Typical Deliverables
Precision CNC brass RF welding electrode dies and grounding plates
Tensile pull-test records across weld seam per ASTM F88
Hydrostatic pressure burst test certificates
Bioburden and endotoxin test clearance reports
⇌
Off-the-shelf component cross-over:
Source medical tubing and bag ports for RF welding.
✓Site states ISO 13485 certification— found“An ISO 13485:2016 certified contract manufacturer utilizing radio” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as VESTA: FEI 2182291; Contract Manufacturer; Franklin, WI · FDA record ↗ · checked 2026-10-20
Option 3Carona Medical
caronamedical.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) caronamedical.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Radiofrequency (RF) Polymer Manifold Sealing (Engineering Primer & Selection Guide)Expand ↓
RF welding excites molecular dipoles in polar plastics with 27.12 MHz radio waves, fusing polymer sheets from the inside out in milliseconds without scorching.
High-Burst Fluid Containment
Weld seams equal or exceed the parent film tensile strength, providing fail-safe containment for biohazardous fluids, blood products, and contrast media.
Microbiological validation and ongoing routine verification of terminal radiation sterilization (gamma and E-beam). Includes repetitive bioburden extraction, recovery factor calculation, verification dose experiments, and sterility test cultures.
Governing Consensus Standards
ISO 11137-1 — Requirements for development, validation, and routine control ISO 11137-2 — Method 1, Method 2, and VDmax25/VDmax15 verification ISO 11737-1 — Bioburden enumeration, recovery efficiency, and validation
Typical Deliverables
Bioburden recovery efficiency report (exhaustion or inoculation method)
Sub-lethal verification dose irradiation coordination and execution
14-day bacteriostasis / fungistasis (B/F) validated sterility test certificates
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “registered to the ISO 13485 Quality Standards, and”, not counted (qualified: "adheres").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“pharmaceutical, biotech and medical device industries worldwide” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “bioburden” or “dose audit…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About Sterility Dose Audit & Bioburden Testing (Engineering Primer & Selection Guide)Expand ↓
Radiation sterilization requires ongoing quarterly dose audits to prove that routine manufacturing bioburden has not exceeded the validated lethality threshold.
The VDmax Method
VDmax25 confirms that a 25 kGy sterilization dose delivers a 10^-6 Sterility Assurance Level (SAL) by challenging a sub-lethal dose on 100 product samples.
✓Site states ISO 13485 certification— found“ISO 13485:2016 Certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“Certified quality management system according to ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: DE.
what was checked ↗
· checked 2026-10-20
About Microfluidics & Diagnostic Cartridge Tooling (Engineering Primer & Selection Guide)Expand ↓
Point-of-care diagnostics require microscopic fluid control with zero bubble entrapment and precise dry-reagent dissolution.
Solventless Laser & Ultrasonic Bonding
Microfluidic layers are bonded without glue using precision laser transmission welding or thermal diffusion to prevent channel clogging and reagent poisoning.
Key Focus: DSC melting point, glass transition Tg, TGA degradation, melt flow index (MFI)
Contract material characterization and thermal analysis of raw medical resins and processed implants. Identifies glass transition (Tg), crystalline melting point (Tm), molecular weight distribution (MWD), and thermal stability.
Governing Consensus Standards
ASTM D3418 — Enthalpy of fusion and crystalline percent calculation ASTM E1131 — Polymer degradation, filler content, and moisture loss
Typical Deliverables
Differential Scanning Calorimetry (DSC) heat-flow thermograms with calculated crystallinity
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MO.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: KY, NY.
what was checked ↗
· checked 2026-10-20
About Thermal Analysis & Polymer Rheology (DSC/TGA/GPC) (Engineering Primer & Selection Guide)Expand ↓
Catheter reflow, injection molding, and gamma sterilization alter polymer chain length and crystallinity, impacting burst strength and flex fatigue.
Bioresorbable Polymer Tracking
For PLLA/PLGA stents and orthopedic pins, GPC molecular weight tracking proves predictable in-vivo degradation kinetics.
✓Site says it serves medical devices— found“world’s leading pharmaceutical, medtech and in vitro” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “overmold…” or “over-mold…” or “overmould…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“Quality Management System (QMS) certified to ISO 13485.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as PHILLIPS-MEDISIZE, LLC: FEI 3004058281; Contract Manufacturer; New Richmond, WI · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Spectrum Plastics Group: FEI 1000115735; Contract Manufacturer; Saint Louis Park, MN · FDA record ↗ · checked 2026-10-20
✓Site says it serves medical devices— found“understand the complexities of manufacturing medical devices.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “overmold…” or “over-mold…” or “overmould…”.
what was checked ↗
· checked 2026-10-20
–Site states ISO 13485 certification— not checkedgroup statement does not name the company. Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as JunoPacific, Inc.: FEI 3002623849; Contract Manufacturer; Brooklyn Park, MN · FDA record ↗ · checked 2026-10-20
About Surgical Handle Ergonomic Overmolding (Engineering Primer & Selection Guide)Expand ↓
Surgeons require tactile grip stability even when gloves are wet with blood and saline, necessitating chemical bonding that will never peel during autoclaving.
Mechanical Interlocks & Priming
Combining chemical adhesion primers with CNC undercut grooves on the metal shank guarantees zero slippage under high torque orthopedic rotation.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, NY.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “that meet your ISO 13485, GMP/GLP, QSR and”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX, WI.
what was checked ↗
· checked 2026-10-20
About Medical Metrology & Sensor Calibration (Engineering Primer & Selection Guide)Expand ↓
FDA requires that all equipment used to demonstrate product conformity—from micrometer calipers to cleanroom particle counters—be calibrated against NIST-traceable standards.
Guardbanding & Uncertainty
ISO 17025 calibration applies guardbanding rules so that measurement uncertainty does not lead to false acceptance of out-of-spec device components.
Precision multi-layer rotary die cutting, laminating, and assembly of wearable medical patches, biosensor adhesives, and ostomy borders. Specializes in skin-contact adhesives (medical acrylics, silicones, and hydrocolloids) with clean release liners.
Governing Consensus Standards
ISO 10993-10 — Biocompatibility of prolonged skin-contact adhesive matrices ASTM D3330 — Peel force testing to stainless steel and simulated skin
Typical Deliverables
Precision die-cut adhesive kiss-cut sheets or continuous roll stock
✓Site states ISO 13485 certification— found“to announce it has achieved ISO 13485:2016 certification.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as MARIAN MONTICELLO: FEI 3003866267; Contract Manufacturer, Repackager/Relabeler; Monticello, IN · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“Tapecon is ISO 13485:2016 registered.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as TAPECON INC.: FEI 3000187060; Contract Manufacturer; Buffalo, NY · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as 3M COMPANY: FEI 2110898; Complaint File Establishment, Specification Developer, Manufacturer; Saint Paul, MN · FDA record ↗ · checked 2026-10-20
About Wearable Patch Converting & Skin Adhesives (Engineering Primer & Selection Guide)Expand ↓
Modern wearable monitors must adhere reliably to dynamic human skin for 7 to 14 days while remaining breathable, water-resistant, and gentle to remove without epidermal stripping.
Silicone Gel vs. Medical Acrylic
Gentle silicone adhesives prevent skin tears in fragile neonatal and geriatric skin, whereas tackified medical acrylics offer maximum hold for multi-day sports monitors.
Contract automated micro-machining of catheter shaft walls and guidewires. Operations include rotational OD taper centerless grinding of core wires, automated punch grinding of oval side-holes, and skiving of braided jacket layers for pull-ring terminations.
Governing Consensus Standards
ISO 10555-1 — Tensile strength across skived and notched shaft regions ISO 13485 — Optical vision inspection and burr-free edge verification
Typical Deliverables
Automated vision inspection reports measuring hole dimensions and edge radii
Tensile break-force verification across side-hole and skived sections
Burr-free lumen certification under 50x magnification
Custom skiving knife tooling and precision grinding program archives
⇌
Off-the-shelf component cross-over:
Prepare braided shafts for pull-wire ring terminations and side ports.
✓Site says it serves medical devices— found“Medical Catheter & Medical Device Tubing Manufacturing” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “skiv…” or “grind…” or “slit…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“control and certifications include ISO 13485:2016, defining the” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: AZ.
what was checked ↗
· checked 2026-10-20
–Site states ISO 13485 certification— not checkedno ISO 13485 mention on 8 pages read; quality page not read. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL.
what was checked ↗
· checked 2026-10-20
About Catheter Tip Grinding, Slitting & Skiving (Engineering Primer & Selection Guide)Expand ↓
Side holes and steering notches must be cut without snagging internal braided wires or leaving microscopic plastic burrs that could detach into the bloodstream.
Burr-Free Lumen Verification
Cryogenic rotary punch cutting creates pristine hole edges with zero internal lumen occlusion, ensuring smooth guidewire and contrast delivery.
✓Site states ISO 13485 certification— found“are certified to ISO 9001:2015, ISO 13485:2016, ISO” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, DE.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Hermetic Brazing & Ceramic Feedthroughs (Engineering Primer & Selection Guide)Expand ↓
Active implantable pacemakers, cochlear implants, and neurostimulators rely on ceramic brazing to insulate electrical telemetry pins for decades inside the saline human body.
Key Focus: Li-ion battery packs, UN 38.3 transport certification, IEC 62133 safety, smart BMS
Contract design, cell matching, ultrasonic wire bonding, and automated assembly of custom medical battery packs. Features redundant battery management system (BMS) safety circuitry, thermal runaway containment, and UN 38.3 / IEC 62133-2 testing.
Governing Consensus Standards
IEC 62133-2 — Safety under forced discharge, external short-circuit, and thermal abuse UN 38.3 — Altitude simulation, thermal shock, vibration, impact, and overcharge
Typical Deliverables
Comprehensive UN 38.3 Test Summary & Certification for commercial air transport
IEC 62133-2 CB Scheme safety test report for global regulatory submissions
Battery Management System (BMS) schematic with redundant hardware overvoltage protection
Cell matching and cycle life discharge degradation curves
⇌
Off-the-shelf component cross-over:
Source internal medical power supplies and charging cradles.
✓Site states ISO 13485 certification— found“China are certified to ISO 13485 manufacturing standards.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as INVENTUS POWER: FEI 3012931014; Contract Manufacturer; Woodridge, IL · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NY.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
About Medical Battery Pack Engineering & UN 38.3 (Engineering Primer & Selection Guide)Expand ↓
Life-critical surgical and monitoring devices demand fail-safe battery architecture that prevents thermal propagation even during catastrophic internal cell failure.
Redundant BMS Protection
Medical BMS boards incorporate dual hardware secondary overvoltage and thermal cutoff fuses that trigger independently of software algorithms.
Medical Device Cybersecurity & Penetration Testing
Key Focus: FDA cybersecurity readiness, medical pen testing, AAMI TIR57 threat models, SBOM
Contract cybersecurity verification for connected, wireless, and cloud-linked medical devices. Covers architectural threat modeling (STRIDE), static/dynamic binary analysis, network penetration testing, and Software Bill of Materials (SBOM) generation.
Governing Consensus Standards
AAMI TIR57 — Threat modeling, vulnerability assessment, and risk controls FDA Cybersecurity (2023) — eSTAR section 12 premarket expectations, SBOM, and incident plans
Typical Deliverables
Comprehensive Medical Device Penetration Test Report with CVSS 3.1 severity scorings
AAMI TIR57 compliant Threat Model and Attack Surface Assessment
Machine-readable Software Bill of Materials (SBOM) in SPDX and CycloneDX formats
FDA Premarket Cybersecurity eSTAR documentation packet with remediation verification
⇌
Off-the-shelf component cross-over:
Fix discovered vulnerabilities directly in your IEC 62304 software pipeline.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“and serve as IDS/IPS for Medical Devices.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “cybersecurity” or “cyber security” or “penetration test…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, IL.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CO.
what was checked ↗
· checked 2026-10-20
About Medical Device Cybersecurity & Penetration Testing (Engineering Primer & Selection Guide)Expand ↓
Under the US Consolidated Appropriations Act (FD&C Act section 524B), FDA possesses statutory authority to refuse to accept any 510(k) or PMA that fails to demonstrate robust cybersecurity.
Beyond General IT Pen Testing
Medical penetration testing focuses on patient safety hazards—such as malicious dosage overrides or telemetry eavesdropping—rather than just server data leaks.
Key Focus: EU MDR PSUR authoring, FDA eMDR reporting, post-market clinical follow-up, vigilance
Contract execution of regulatory post-market surveillance for commercial medical devices. Includes complaint intake, adverse event trending, FDA 21 CFR 803 electronic Medical Device Reporting (eMDR), EU MDR Periodic Safety Update Reports (PSUR), and PMCF plans.
Governing Consensus Standards
ISO 20416 — Systematic gathering, recording, and analysis of device data EU MDR Articles 83–86 — Mandatory annual safety reporting to Notified Bodies 21 CFR 803 — 30-day and 5-day electronic reports of adverse events and malfunctions
Typical Deliverables
Comprehensive EU MDR Periodic Safety Update Report (PSUR) ready for EUDAMED filing
Post-Market Clinical Follow-up (PMCF) evaluation plan and annual clinical review report
Validated complaint handling and trending charts with statistical signal detection
FDA eMDR submission confirmation records for reportable incidents and malfunctions
⇌
Off-the-shelf component cross-over:
Feed post-market clinical findings directly into your annual CER updates.
✓Site states ISO 13485 certification— found“Benefits of being an ISO 13485 certified company” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, TX.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“to be certified to ISO 13485:2016, thus self-declaration” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, NL.
what was checked ↗
· checked 2026-10-20
Option 3Quality-Compliance Partners (QCP)
qcpconsulting.comWebsite did not answer as this company on 2026-10-20
📍 Minneapolis, MN / Dublin, Ireland
PMCF survey design, complaint statistical process control (SPC), CAPA remediation
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but the pages read name only “qcp” and state nothing Quality-Compliance Partners (QCP) is listed for (domain may belong to someone else)) qcpconsulting.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedonly “qcp” is named, too short or common to identify the company. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredonly “qcp” is named, too short or common to identify the company. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedonly “qcp” is named, too short or common to identify the company. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, IE.
what was checked ↗
· checked 2026-10-20
About Post-Market Surveillance (PMS) & Vigilance (Engineering Primer & Selection Guide)Expand ↓
Regulatory oversight no longer ends at device clearance; under EU MDR and FDA rules, manufacturers must proactively collect and analyze real-world clinical data throughout the commercial lifecycle.
Proactive vs. Reactive PMS
Proactive PMS actively surveys clinicians and tracks scientific literature, whereas reactive vigilance handles incoming hospital complaints and adverse event logs.
Rapid optical prototyping and ray tracing simulation for diagnostic, surgical, and therapeutic optics. Services encompass sequential and non-sequential Zemax ray tracing, modulation transfer function (MTF) optimization, fiber-optic coupling, LED/laser diode alignment, and precision optomechanical benchtop breadboard validation.
Governing Consensus Standards
ISO 10110 — Standardized optical fabrication notations and surface tolerances IEC 60825-1 — Equipment classification, beam hazard levels, and optical containment ISO 8600-1 — Optical field of view, distortion, and illumination requirements
Typical Deliverables
Zemax OpticStudio prescription files (.zmx) and 3D CAD STEP ray bundle models
✓Site states ISO 13485 certification— found“FISBA AG → ISO 13485:2016” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 7 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL, LV.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ, DE.
what was checked ↗
· checked 2026-10-20
About Optical Bench Prototyping & Ray Tracing (Engineering Primer & Selection Guide)Expand ↓
Medical imaging systems and laser scalpels fail quickly if tolerance stack-ups between optics and mechanical housings are not modeled upfront in non-sequential ray tracing software.
Sequential vs. Non-Sequential Ray Tracing
Sequential ray tracing models light through predefined lens surfaces to calculate resolution and focal length.
Non-Sequential ray tracing simulates stray reflections, scatter, and glare from mechanical barrels and tissue interfaces.
Advanced non-linear Finite Element Analysis (FEA) and Computational Fluid Dynamics (CFD) for FDA pre-market submissions. Specializes in superelastic Nitinol fatigue life (Goodman/constant-life diagrams), balloon expansion plasticity, orthopedic bone-implant strain shielding, drop test shock dynamics, and non-Newtonian blood shear hemolysis modeling.
Governing Consensus Standards
ASME V&V 40 — Standard framework for credibility and risk-informed model validation FDA Guidance 2016 — Mandatory documentation structure for FEA/CFD filings ASTM F2514 — Radial loading, deformation, and stress-strain verification
Typical Deliverables
Comprehensive ASME V&V 40 Verification and Validation Report for FDA 510(k)/PMA
–Site states ISO 13485 certification— not checkedgroup statement does not name the company. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: PA, TX.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, NY.
what was checked ↗
· checked 2026-10-20
About Medical FEA & Computational Fluid Dynamics (CFD) (Engineering Primer & Selection Guide)Expand ↓
FDA requires computational models to undergo rigorous credibility assessment per ASME V&V 40, ensuring virtual predictions match physical benchtop validation.
ASME V&V 40 Credibility Framework
Model credibility is scaled to the "influence" of the simulation on clinical safety decisions and the "consequence" of an erroneous decision.
Engineering fabrication of physiologically realistic synthetic tissue models and patient-derived 3D benchtop vascular flow phantoms. Constructed from compliant silicones, hydrogels, and polyurethane resins with anatomical compliance, friction coefficients, and tortuosity matched to diseased human vessels for catheter trackability, deliverability, and deployment validation.
Governing Consensus Standards
ASTM F2477 — Compliant mock vessels and dynamic cyclic radial pressurization ASTM F2394 — Anatomical model guide catheter tortuous path access ISO 25539-1 — In vitro delivery and deployment bench models
Typical Deliverables
Patient-specific silicone vascular phantom cast from clinical DICOM CT/MRI scans
Pulsatile cardiovascular benchtop flow loop with digital pressure/flow transducers
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 6 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, CH.
what was checked ↗
· checked 2026-10-20
Option 3Biomodex
biomodex.comWebsite did not answer as this company on 2026-10-20
📍 Boston, MA / Paris, France
3D multi-material patient-specific neurovascular and structural heart test benches
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) biomodex.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, FR.
what was checked ↗
· checked 2026-10-20
About Synthetic Anatomical Models & Benchtop Vascular Phantoms (Engineering Primer & Selection Guide)Expand ↓
Testing transcatheter delivery systems in compliant silicone anatomical models drastically accelerates design iterations before committing to expensive in-vivo animal trials.
Anatomical Compliance Matching
Rigid plastic tubing fails to replicate the clinical tactile feel of human arteries during catheter tracking.
Precision-cast platinum silicones are tuned to replicate arterial wall compliance (3–7% diameter dilation per 100 mmHg pressure pulse).
Key Focus: ASME Y14.5-2018 GD&T, 1D/3D Monte Carlo stack-up, statistical tolerance clearance studies
Comprehensive Geometric Dimensioning and Tolerancing (GD&T) definition and statistical stack-up analysis for critical medical assemblies. Eliminates binding, leak paths, and assembly line lockups by conducting worst-case, Root Sum of Squares (RSS), and 3D Monte Carlo simulations across temperature extremes and component shrinkage distributions.
Governing Consensus Standards
ASME Y14.5-2018 — Standard engineering symbols, datums, and geometric tolerances ASME Y14.5.1M — Mathematical foundation for tolerance calculations ISO 286-1 — Standard hole and shaft clearance classes
Typical Deliverables
Fully constrained ASME Y14.5-2018 2D drawing packages with validated datum reference frames
1D and 3D Monte Carlo tolerance stack-up spreadsheet and simulation report (100,000 iterations)
Predicted defect rate (PPM / Cp / Cpk) for critical clearance and interference fits
Sensitivity Pareto charts highlighting the top variance drivers in the assembly stack
⇌
Off-the-shelf component cross-over:
Need ASME Y14.5-2018 compliant native SolidWorks or Creo drafting packages?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
Option 2Martin Associates GD&T
martinassociates.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_SSL_TLSV1_ALERT_INTERNAL_ERROR); plain http:// answers) martinassociates.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_SSL_TLSV1_ALERT_INTERNAL_ERROR); plain http:// answers). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_SSL_TLSV1_ALERT_INTERNAL_ERROR); plain http:// answers). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_SSL_TLSV1_ALERT_INTERNAL_ERROR); plain http:// answers). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: AZ, MN.
what was checked ↗
· checked 2026-10-20
Option 3Variation Systems Analysis (VSA / Siemens)
sw.siemens.comWebsite did not answer as this company on 2026-10-20
📍 Plano, TX / Detroit, MI
Teamcenter Quality, 3D non-rigid variation simulation, complex mechanism fits
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but no page read names Variation Systems Analysis (VSA / Siemens) (domain may have changed hands)) sw.siemens.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI, TX.
what was checked ↗
· checked 2026-10-20
About GD&T & Statistical Tolerance Stack-Up Analysis (Engineering Primer & Selection Guide)Expand ↓
Tightening every dimension to ±0.0005″ drives manufacturing costs through the roof; statistical tolerance analysis reveals where tolerances can safely be relaxed without risking clinical assembly failure.
Worst-Case vs. Statistical Monte Carlo
Worst-case stack-up assumes all parts are made at extreme min/max conditions simultaneously, often producing unrealistically impossible requirements.
Monte Carlo analysis samples actual manufacturing probability distributions (Gaussian, skewed) to predict true ppm defect rates.
Medical Core Wire Centerless Grinding & Taper Grinding
High-precision centerless OD grinding and multi-stage CNC taper grinding for medical core wires, mandrels, stylets, and trocar blanks. Grinds continuous smooth transitions, flat-to-round profiles, and parabolic tapers in stainless steel (304V) and superelastic Nitinol down to 0.0015″ (38 µm) distal tip diameters with sub-micron surface finishes.
Governing Consensus Standards
ISO 11070 — Core wire fracture, flexure, and tensile limits ASTM A313 — Tensile and mechanical properties of medical core wire ASTM F2063 — Superelastic Nitinol wire material requirements
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as CUSTOM WIRE TECHNOLOGIES, INC: FEI 3007544874; Contract Manufacturer; Port Washington, WI · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 and FDA QSR compliant.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Tegra Medical - Franklin, MA: FEI 3002758924; Contract Manufacturer; Franklin, MA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016 Certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
About Medical Core Wire Centerless Grinding & Taper Grinding (Engineering Primer & Selection Guide)Expand ↓
The tactile steerability and prolapse resistance of an interventional guidewire depends almost entirely on the continuous taper geometry ground into its metallic core.
Multi-Stage vs. Parabolic Tapers
Multi-stage step tapers provide distinct flexibility zones (stiff proximal body, transition barrel, and floppy distal tip).
Ultrafast laser micro-drilling and high-speed trepanning of micro-apertures in metallic tubes, foils, and polymers. Produces holes down to 5 µm with zero heat-affected zone (HAZ), zero dross, and aspect ratios up to 20:1 for embolic protection filters, drug elution pores, flow restrictors, and micro-nozzles.
Governing Consensus Standards
ISO 13485 — Traceability and process validation for micro-machining ASTM F2063 — Laser processing effects on Nitinol transformation temperatures ISO 14971 — Micro-orifice occlusion and edge roughness hazard analysis
Typical Deliverables
Micro-drilled components with optical microscope and SEM hole diameter verification
Hole taper, circularity, and edge radius inspection data sheets
Flow calibration test reports (flow rate vs. differential pressure)
Ultrasonically passivated and particle-free cleaned components in cleanroom packaging
⇌
Off-the-shelf component cross-over:
Need thin-wall stainless or Nitinol tubing blanks ready for laser perforation?
✓Site says it serves medical devices— found“Rapid Prototyping of Medical Devices and Implants” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “laser drill…” or “micro drill…” or “micro-drill…” or “micro-hole…” or “micro hole…” or “microhole…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“US-based contract manufacturer to receive ISO 13485 registration.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as NORMAN NOBLE, INC.: FEI 3002755653; Contract Manufacturer; Highland Heights, OH · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Micro-Laser Drilling & Orifice Trepanning (Engineering Primer & Selection Guide)Expand ↓
Mechanical micro-drills wander and break below 100 microns; ultrafast lasers drill sub-10-micron holes in hard alloys by optical field ionization without melting surrounding material.
Femtosecond Laser vs. Mechanical Drilling
Mechanical micro-drilling leaves burrs and tool marks that can nucleate fatigue cracks or cause thrombus formation.
Femtosecond lasers deliver energy in pulses shorter than thermal conduction times, vaporizing material directly with zero recast layer.
Thermal lamination and multi-layer polymer reflow for steerable, diagnostic, and delivery catheter shafts. Encapsulates etched PTFE liners, wire braids, and coiling inside variable-durometer Pebax, Nylon, and polyurethane outer jackets using hot air reflow jaws and FEP heat shrink jackets.
Governing Consensus Standards
ISO 10555-1 — Shaft tensile force, kink resistance, and burst limits ASTM D638 — Polymer weld and transition joint tensile testing ISO 13485 — Critical process parameter (CPP) validation for thermal bonding
✓Site states ISO 13485 certification— found“As an ISO 13485 certified and FDA-registered partner,” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as BIOMERICS: FEI 3008998256; Contract Manufacturer; Salt Lake City, UT · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“control and certifications include ISO 13485:2016, defining the” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as TELEFLEX MEDICAL: FEI 3007134520; Specification Developer, Manufacturer; Athlone Westmeath, IE · FDA record ↗ · checked 2026-10-20
About Catheter Shaft Lamination & Multi-Layer Reflow (Engineering Primer & Selection Guide)Expand ↓
Achieving a smooth, seamless transition from a stiff proximal pushable shaft to an ultra-floppy, atraumatic distal tip requires tightly controlled thermal reflow profiles.
FEP Heat Shrink Encapsulation
Layers of etched PTFE liner, braided wire, and pre-cut Pebax tubing segments are assembled onto a silver-plated copper mandrel.
FEP heat shrink is slipped over the stack; as heat is applied, the FEP shrinks and compresses the molten Pebax through the braid into the etched liner.
Key Focus: Titanium Grade 1/2 deep draw shells, pacemaker shields, micro-eyelets to ±0.0002″
High-speed precision deep draw stamping of miniature and seamless metal enclosures for active implantable and surgical devices. Specializes in medical Grade 1 and Grade 2 Titanium, 316LVM, and platinum alloys for pacemaker shields, implantable telemetry cans, neurostimulator battery cases, and marker eyelets with draw ratios exceeding 3:1.
Governing Consensus Standards
ISO 13485 — Tool validation, dimensional inspection, and lot control ASTM F67 — Grade 1–4 Titanium chemistry and mechanical ductility ASTM F138 — Medical 316LVM implant grade stainless steel
Typical Deliverables
Deep drawn seamless metal shells with coordinate measuring machine (CMM) dimensional reports
Wall thickness uniformity and corner radius thinning profile inspection data
Burr-free edge trim and hermetic laser weld flange flatness certification
Ultrasonically degreased and passivated shells in anti-static cleanroom trays
⇌
Off-the-shelf component cross-over:
Need flat planar stamping, lead frames, or multi-slide surgical components?
✓Site says it serves medical devices— found“precision and safety demands of medical technology.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “deep draw…” or “deep-draw…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: RI.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL.
what was checked ↗
· checked 2026-10-20
Option 3Bravo Medical (Bravo Group)
bravomedical.comWebsite did not answer as this company on 2026-10-20
📍 Minneapolis, MN / Costa Rica
Micro-miniature eyelets, marker bands, endoscopic surgical staples and clips
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but the domain is parked or for sale) bravomedical.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, CR.
what was checked ↗
· checked 2026-10-20
About Deep Draw Metal Stamping & Titanium Eyelets (Engineering Primer & Selection Guide)Expand ↓
Deep drawing transforms flat metallic coils into high-aspect-ratio seamless cylinders and prismatic cans through sequential drawing dies without welding seams.
Titanium Work Hardening and Annealing
Medical titanium work hardens rapidly during deep drawing operations, requiring intermediate vacuum annealing stages to restore ductility between progressive draws.
Precision tool radii prevent localized necking and wall-thinning on implant battery enclosures.
Chemical milling and photo-chemical machining (PCM) of thin metal foils and sheets for precision medical devices. Produces perfectly flat, stress-free, and burr-free components including lancets, surgical micro-blades, fluidic filter meshes, electrical lead frames, and battery contacts without mechanical deformation or heat-affected zones.
Governing Consensus Standards
ISO 13485 — Process repeatability and chemical bath control validation ASTM F899 — Surgical instrument metallurgy ASTM F67 — Grade 1–4 Titanium sheet specifications
Typical Deliverables
Chemical etched sheet sheets with optical vision system dimensional reports
Burr-free and stress-free edge qualification micrographs (zero thermal recast)
Sheet yield and aperture size distribution statistical reports
Passivated, de-tabbed, and cleanroom vacuum-packed metal components
⇌
Off-the-shelf component cross-over:
Need tube cutting or 3D geometry rather than flat sheet chemical etching?
✓Site states ISO 13485 certification— found“The 13485:2016 certification demonstrates the fact that Tech” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as TECH-ETCH, INC.: FEI 1000297541; Contract Manufacturer; Plymouth, MA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · certificate ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: PA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, GB.
what was checked ↗
· checked 2026-10-20
About Photo-Chemical Etching & Metal Micro-Machining (Engineering Primer & Selection Guide)Expand ↓
Unlike stamping which creates shearing stress, or laser cutting which introduces heat-affected zones, chemical etching dissolves metal simultaneously from both sides, leaving zero residual stress.
Tooling Speed and Economics
Photo-tooling uses high-resolution digital photographic film rather than expensive hard steel stamping dies, cutting initial tooling turnaround down to 48 hours.
Complexity is free: whether a sheet has 1 hole or 10,000 micro-apertures, the etching cycle time is identical.
Key Focus: Hypodermic tube flaring to ISO 80369-7, rotary swaging, hydraulic bulging, pencil-point tipping
Cold and thermal end-forming of small-diameter stainless steel and Nitinol hypodermic tubing. Operations include rotary swaging, pneumatic flaring to ISO 80369-7 luer tapers, mechanical bulging for silicone O-ring retention, tube necking, bead rolling, and closed bullet-nose or pencil-point tipping for puncture cannulae.
Governing Consensus Standards
ISO 80369-7 — 6% Luer connector mechanical geometry and flare angles ISO 9626 — Tubing tensile strength, stiffness, and wall tolerances ASTM A269 — General medical tubing metallurgical requirements
Typical Deliverables
Formed tubular components with optical comparator flare angle and concentricity reports
ISO 80369-7 mechanical luer gauge fit verification test data (no liquid/air leakage)
Wall thinning and material integrity cross-sectional metallographic micrographs
Ultrasonically degreased and passivated tubular parts in cleanroom packaging
⇌
Off-the-shelf component cross-over:
Need raw gauge-sized RW, TW, or UTW stainless steel tubing blanks?
✓Site states ISO 13485 certification— found“company (also ISO 9001/13485 certified ), our manufacturing” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as VITA NEEDLE CO.: FEI 1213680; Contract Manufacturer, Manufacturer; Needham, MA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“our certifications, including ISO 9001 and ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“to minimally invasive surgical instruments, high-quality precision” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “flar…” or “swag…” or “end form…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Hypodermic Tube Flaring, Bulging & Swaging (Engineering Primer & Selection Guide)Expand ↓
Transitioning a stainless steel tube from its drawn diameter into a leak-tight mechanical luer lock or tapered trocar requires careful control over material strain hardening.
Preventing Longitudinal Flare Cracking
Severe cold working during flaring can cause longitudinal split cracks along the grain boundary of drawn tubing.
Annealed or lightly cold-worked hypodermic stock combined with multi-stage rotary punch geometries ensures crack-free flares that seal reliably.
Femtosecond Laser Cutting of Nitinol Heart Valves & Scaffolds
Sub-picosecond ultrafast laser cutting and post-processing of superelastic and shape-memory Nitinol tubing and sheets. Produces transcatheter aortic valve replacement (TAVR) frames, intracranial flow diverters, peripheral vascular stents, and orthopedic shape-memory staples with zero thermal recast layer, zero heat-affected zone (HAZ), and strut widths down to 25 µm.
Governing Consensus Standards
ASTM F2063 — Nitinol chemical composition and transformation temperatures (Af) ISO 25539-1 — Stent strut integrity, fatigue life, and surface finish ASTM F2129 — Corrosion resistance and breakdown potential of electropolished Nitinol
✓Site states ISO 13485 certification— found“ISO 13485: Certified” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Confluent Medical Technologies, Inc: FEI 3007635982; Specification Developer; Fremont, CA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“US-based contract manufacturer to receive ISO 13485 registration.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as NORMAN NOBLE, INC.: FEI 3002755653; Contract Manufacturer; Highland Heights, OH · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“to DIN EN ISO 13485 (replacing certification according” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: DE.
what was checked ↗
· checked 2026-10-20
About Femtosecond Laser Cutting of Nitinol Heart Valves & Scaffolds (Engineering Primer & Selection Guide)Expand ↓
Conventional fiber lasers melt Nitinol, generating a brittle nickel-rich recast layer that ruins high-cycle fatigue life; femtosecond pulses ionize the alloy directly with zero thermal penetration.
Zero Heat-Affected Zone (HAZ)
Femtosecond laser pulses are on the order of 10^-15 seconds—faster than heat can conduct into adjacent crystal lattices.
The resulting cut has clean vertical sidewalls with no slag or dross, dramatically reducing chemical etching time and preserving strut fatigue endurance.
Specialized micro-injection molding and multi-material insert encapsulation for micro-optics, implants, and diagnostics. Injects high-performance engineering thermoplastics (PEEK, LCP, bioabsorbable PLA/PLGA, polycarbonate) onto metallic wire meshes, optical fiber bundles, micro-stamped contacts, and ceramic sensors with shot weights down to 0.001 grams.
Governing Consensus Standards
ISO 13485 — Tool qualification, cleanroom molding, and statistical process control ASTM F2026 — Implantable PEEK chemical and physical purity ISO 20417 — Traceability and resin lot batch records
Typical Deliverables
Precision micro-molded components with multi-sensor CMM and white-light interferometer inspection
✓Site states ISO 13485 certification— found“operations are certified to ISO 13485 , I” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as ACCUMOLD LLC: FEI 3009627506; Contract Manufacturer; Ankeny, IA · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedrobots.txt unreachable (HTTP 526), treated as disallow (RFC 9309). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (robots.txt unreachable (HTTP 526), treated as disallow (RFC 9309)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (robots.txt unreachable (HTTP 526), treated as disallow (RFC 9309)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (robots.txt unreachable (HTTP 526), treated as disallow (RFC 9309)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: WI.
what was checked ↗
· checked 2026-10-20
About Multi-Material Insert Micro-Molding & PEEK Filters (Engineering Primer & Selection Guide)Expand ↓
Molding molten PEEK at 400°C around fragile 0.001″ wire meshes without crushing or flashing requires specialized micro-tooling with micron-level steel alignment.
Micro-Molding Machine Architecture
Standard injection molding screws degrade tiny amounts of polymer due to excessive residence time.
Specialized micro-molding presses use separate extrusion screws and ultra-miniature injection plungers to deliver sub-milligram shots in milliseconds.
Dark Anneal Laser Marking & Corrosion-Resistant UDI
Key Focus: Dark anneal laser marking, passivated surgical stainless UDI 2D DataMatrix, zero rust
Corrosion-resistant thermal annealing laser marking for surgical instruments, orthopedic implants, and guidewires. Generates high-contrast black oxide marks beneath the metallic surface without vaporizing material, preserving the chromium oxide passive layer and passing rigorous 100-cycle autoclave corrosion challenges per ASTM F1089.
Governing Consensus Standards
FDA 21 CFR 830 — Permanent direct part marking (DPM) on reusable devices ISO 13485 — Traceability and direct part marking validation ASTM F1089 — Boil and copper sulfate corrosion testing after marking ISO 15415 — 2D DataMatrix grading (contrast, modulation, damage)
Typical Deliverables
Direct part marked components with ISO 15415 2D DataMatrix barcode verification reports (Grade A)
ASTM F1089 boil test and copper sulfate corrosion resistance verification certificate
✓Site says it serves medical devices— found“Is Your Medical Device Sharp Enough?” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “laser mark…” or “anneal…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 and FDA QSR compliant.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Tegra Medical: FEI 3008647423; Contract Manufacturer; Hernando, MS · FDA record ↗ · checked 2026-10-20
–Site says it serves medical devices— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI.
what was checked ↗
· checked 2026-10-20
Option 3Litron Laboratories & Services
litron.comWebsite did not answer as this company on 2026-10-20
📍 Agawam, MA
Medical laser marking, dark anneal UDI, laser hermetic welding, glovebox sealing
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to pacaero.com, which does not name Litron Laboratories & Services) litron.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About Dark Anneal Laser Marking & Corrosion-Resistant UDI (Engineering Primer & Selection Guide)Expand ↓
Ablation laser marking carves away the metal, creating crevices where salt and autoclave steam initiate rust; laser annealing gently oxidizes the subsurface without breaking the surface polish.
MOPA Fiber Laser Subsurface Heating
Master Oscillator Power Amplifier (MOPA) lasers allow independent pulse duration and frequency tuning.
By delivering long, low-energy pulses, the surface metal is heated to glowing temperatures without vaporizing, creating a deep optical oxide layer that remains corrosion-free.
✓Site states ISO 13485 certification— found“our facilities are ISO 13485:2016 certified to meet” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“co-development partner, Teleflex Medical OEM supports industry” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “co-extru…” or “coextru…” or “multi-lumen” or “multilumen” or “multi lumen”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as TELEFLEX MEDICAL: FEI 3007134520; Specification Developer, Manufacturer; Athlone Westmeath, IE · FDA record ↗ · checked 2026-10-20
About Multi-Lumen & Stripe Radiopaque Co-Extrusion (Engineering Primer & Selection Guide)Expand ↓
Modern interventional catheters require up to 8 separate lumens for guidewires, steering pull-wires, inflation saline, and optical fibers within a single 0.080″ diameter shaft.
In-Line Air Pressure Lumen Control
Each individual lumen requires dynamic micro-air pressure injection through the extrusion die pin to prevent lumen collapse before water quench cooling.
Continuous dual-axis laser and ultrasonic wall monitors adjust puller speeds in real-time to maintain ±0.0005″ wall tolerances.
Non-contact UV and excimer laser ablation for stripping ultra-thin polymer insulation (polyimide, PTFE, ETFE, parylene) from miniature electrical conductors, medical coils, and sensor leads. Vaporizes organic polymer jackets cleanly without nicking, scratching, or altering the temper of precious metal (platinum, gold) or copper alloy conductors.
Governing Consensus Standards
ISO 13485 — Process validation for micro-assembly and insulation integrity IPC/WHMA-A-620 — Class 3 medical wire strip quality and conductor nick limits ASTM B298 — Conductor plating and surface integrity
Typical Deliverables
Stripped micro-leads with high-magnification optical and SEM inspection reports
Conductor surface integrity certification (100% zero nicking/scraping)
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH.
what was checked ↗
· checked 2026-10-20
Option 2Litron Laboratories
litron.comWebsite did not answer as this company on 2026-10-20
📍 Agawam, MA
Laser wire stripping, fine wire welding, feedthrough pin termination
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to pacaero.com, which does not name Litron Laboratories & Services) litron.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
Option 3SYNEO
syneo.comWebsite did not answer as this company on 2026-10-20
📍 West Palm Beach, FL
Laser and mechanical wire stripping automation, catheter hole punching, slitting
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to dynamo.com, which does not name SYNEO) syneo.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL.
what was checked ↗
· checked 2026-10-20
About Polymer Laser Ablation & Wire Coating Stripping (Engineering Primer & Selection Guide)Expand ↓
Mechanical wire stripping blades scrape and nick micro-conductors down to 40 AWG, creating stress risers that fracture during catheter bending; UV lasers stop dead at the metal boundary.
Wavelength Absorption Differential
Short-wavelength UV (355 nm) and excimer (193/248 nm) photons break molecular polymer bonds directly through photo-chemical ablation.
Because bare metals reflect UV radiation efficiently, the laser energy strips away tough polyimide jackets while leaving the underlying conductor untouched.
High-precision micro-coiling and winding of radiopaque precious metal wires for neurovascular, coronary, and peripheral intervention. Manufactures primary and secondary shape-set coils from 90/10 Platinum-Iridium, gold, and tungsten wire with pitch control down to 0.001″ for embolization, distal guidewire floppy springs, and flexible radiopaque catheter markers.
Governing Consensus Standards
ASTM B684 — 90/10 and 80/20 Pt/Ir metallurgical composition ISO 10555-1 — Radiopacity, joint strength, and flexibility ISO 13485 — Micro-winding tension control and dimensional inspection
Typical Deliverables
Micro-coiled lots with optical vision system pitch and OD measurement reports (±0.0002″)
Primary coil elongation and tensile fracture test verification data
Secondary 3D memory shape setting inspection records (conical, spherical, helical)
Cleaned, degreased, and individually tray-packaged coils ready for delivery catheter loading
⇌
Off-the-shelf component cross-over:
Need cut Pt/Ir or gold swaged marker bands instead of continuous coil windings?
✓Site states ISO 13485 certification— found“EN ISO 13485:2016 Certification” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“contribution: Production of medical technology such as” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “coil…” and (“platinum” or “precious metal…”). Found: precious metals.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as HERAEUS MEDICAL COMPONENTS, LLC: FEI 3008988055; Specification Developer, Complaint File Establishment, Contract Manufacturer; Saint Paul, MN · FDA record ↗ · checked 2026-10-20
✓Site says it serves medical devices— found“for the World’s Most Complex Medical Devices” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “coil…” and (“platinum” or “precious metal…”). Found: coil.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016 Certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
About Radiopaque Platinum Marker Coiling & Windings (Engineering Primer & Selection Guide)Expand ↓
Interventional radiologists navigate tortuous brain vessels under fluoroscopic x-ray; platinum coils provide intense radiopacity combined with extreme mechanical flexibility.
Primary vs. Secondary Shape Setting
A primary micro-coil is tightly wound around a continuous core mandrel to create a flexible spring.
The coil is then wound onto a complex 3D spherical or helical fixture and heat-treated to impart secondary shape memory, allowing it to blossom into an aneurysm sac upon deployment.
Metal Injection Molding (MIM) for Surgical Jaws & Tools
High-volume Metal Injection Molding (MIM) and sintering of complex, articulated surgical instrument components. Produces high-strength surgical grasper jaws, scissor blades, laparoscopic pivots, and stapler anvils from 17-4PH, 316L, and cobalt-chromium alloys at net shape with minimal secondary CNC machining.
Governing Consensus Standards
MPIF Standard 35-MIM — MIM material chemical and mechanical minimum properties ISO 13485 — Tool qualification and sintering furnace validation ASTM F899 — Instrument metallurgy and corrosion resistance
Typical Deliverables
Net-shape sintered metal parts with CMM geometric dimensional and tolerance reports
Metallurgical density certification (>97% theoretical density)
Rockwell hardness and tensile yield test verification data
Passivated, electropolished, and cleanroom-packed surgical tool components
⇌
Off-the-shelf component cross-over:
Need low-volume prototype machined surgical jaws before building MIM tooling?
✓Site says it serves medical devices— found“world’s leading pharmaceutical, medtech and in vitro” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “metal injection” or “mim”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“Quality Management System (QMS) certified to ISO 13485.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as PHILLIPS-MEDISIZE, LLC: FEI 3004058281; Contract Manufacturer; New Richmond, WI · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedredirect our client could not follow (HTTP 307). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (redirect our client could not follow (HTTP 307)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (redirect our client could not follow (HTTP 307)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (redirect our client could not follow (HTTP 307)). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as INDO-MIM LIMITED: FEI 3006516512; Contract Manufacturer; Bangalore Karnataka, IN · FDA record ↗ · checked 2026-10-20
Option 3ARC Group Worldwide
arcgroupworldwide.comWebsite did not answer as this company on 2026-10-20
📍 Longmont, CO
Precision medical MIM, surgical stapler components, miniature instrument joints
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)) arcgroupworldwide.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CO.
what was checked ↗
· checked 2026-10-20
About Metal Injection Molding (MIM) for Surgical Jaws & Tools (Engineering Primer & Selection Guide)Expand ↓
Machining complex articulated surgical graspers on 5-axis CNC mills takes 45 minutes per part; MIM molds them in 15 seconds like plastic, followed by debinding and high-temperature sintering.
Debinding and Sintering Shrinkage
Metal powder is blended with a polymeric binder and injection molded into an oversized "green" part.
Thermal or catalytic debinding removes the binder, and sintering at ~1350°C densifies the metal with an isotropic ~18–20% linear shrinkage to achieve full metallurgical strength.
Surface modification and plasma activation for catheter tubing, polymer housings, and implantable electronics. Cleans organic contaminants at the atomic level and grafts polar functional groups (hydroxyl, carbonyl, carboxyl) onto inert fluoropolymers, silicones, and polyolefins to raise surface energy (dyne levels) for hydrophilic coatings and UV/epoxy adhesive bonding.
Governing Consensus Standards
ASTM D2578 — Dyne solution surface wettability measurement ISO 13485 — Surface preparation process control and aging shelf-life validation ASTM D7490 — Goniometric sessile drop contact angle characterization
Typical Deliverables
Goniometer contact angle and surface energy (dynes/cm) verification test reports
Adhesion peel/shear tensile test data comparing untreated vs. plasma-activated joints
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: WI.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 11 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Atmospheric & Vacuum Plasma Surface Activation (Engineering Primer & Selection Guide)Expand ↓
Inert medical polymers like PTFE and PEEK resist liquid adhesives, resulting in catastrophic bond failure under clinical loads; plasma breaking carbon bonds creates reactive chemical hooks.
Atmospheric vs. Low-Pressure Vacuum Plasma
Atmospheric blown-ion plasma treats localized joint areas on catheter shafts on a moving production line.
Vacuum RF chamber plasma uniformly treats complex 3D internal geometries, narrow lumens, and multi-well microplates in high-density batches.
Key Focus: AMS 2488 Type II titanium anodize, color-coded orthopedic screws, anti-fretting
Electrochemical anodization of titanium and titanium alloy orthopedic screws, plates, dental implants, and surgical instrumentation. Delivers AMS 2488 Type II alkaline gray conversion coatings for galling and fretting wear resistance on threaded interfaces, as well as electrolytic color anodization for intuitive surgical color-coding and size identification.
Governing Consensus Standards
AMS 2488 — Type II gray conversion coating for anti-galling and wear resistance ASTM F86 — Standard cleaning, passivation, and surface prep ISO 13485 — Chemical bath process qualification and lot traceability
Typical Deliverables
Titanium anodized components with color spectrophotometer verification reports (delta-E)
AMS 2488 Type II adhesion tape test and anti-galling torque verification data
Coating thickness and surface microstructure inspection data (SEM / cross-section)
Ultrasonically rinsed, passivated, and cleanroom-packed implantable lots
⇌
Off-the-shelf component cross-over:
Need pre-anodize electropolishing or nitric/citric acid passivation?
✓Site states ISO 13485 certification— found“certificate , ISO 13485: 2016 certificate and AS9100:” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016 and Nadcap Certified.” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN, NJ.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“Benefits For Medical Device Cleaning & Processing” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “anodiz…” or “anodis…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Celco Inc”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: KS.
what was checked ↗
· checked 2026-10-20
About Titanium Color Anodizing & Type II Anti-Galling (Engineering Primer & Selection Guide)Expand ↓
Titanium on titanium threads seize and cold-weld instantly under high installation torque; AMS 2488 Type II conversion coatings replace the soft oxide with an amorphous, wear-resistant barrier.
Color Anodizing vs. Type II Anti-Galling
Color anodizing uses thin-film optical interference: varying voltage controls the transparent oxide thickness (10–200 nm), reflecting specific wavelengths without pigments or dyes.
Type II anodizing is an alkaline bath reaction producing a dense, gray conversion layer specifically formulated to withstand fretting fatigue in orthopedic bone plates and screws.
Application and formulation of sustained-release and non-leaching antimicrobial coatings for indwelling medical devices. Incorporates ionic silver, chlorhexidine, copper complexes, or antimicrobial peptides into hydrophilic or polyurethane matrices to inhibit bacterial colonization, eradicate biofilm formation, and prevent Catheter-Associated Urinary Tract Infections (CAUTI) and Central Line-Associated Bloodstream Infections (CLABSI).
Governing Consensus Standards
ASTM E2180 — Efficacy testing on polymeric surfaces ISO 22196 — Quantitative bacterial reduction assays (Log 3+ kill) ISO 10993-5 — Evaluating mammalian cell viability against antimicrobial leachables
Typical Deliverables
Microbiological log-reduction efficacy test reports against S. aureus, P. aeruginosa, and C. albicans
Active antimicrobial elution kinetics and dissolution curves (30-day release in saline)
Biofilm prevention challenge assay data (confocal laser scanning microscopy)
Coated device samples with cross-hatch adhesion and flex-durability certificates
⇌
Off-the-shelf component cross-over:
Need ISO 10993 cytotoxicity and hemocompatibility assays on antimicrobial chemistry?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as COVALON TECHNOLOGIES INC.: FEI 3005004019; Foreign Private Label Distributor, Complaint File Establishment, Specification Developer, Manufacturer; Mississauga Ontario, CA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016 is certified with BSI.” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NC.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485 certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
About Antimicrobial & Silver-Ion Device Coatings (Engineering Primer & Selection Guide)Expand ↓
Bacteria rapidly synthesize an extracellular polysaccharide matrix on bare plastic within 24 hours of insertion, shielding the colony from systemic intravenous antibiotics.
Balancing Antimicrobial Efficacy and Cytotoxicity
The engineering challenge is delivering sufficient localized antimicrobial potency to achieve a >3-log reduction in pathogens while remaining non-toxic to surrounding endothelial and host cells.
Precision release kinetics ensure silver or peptide release stays strictly within the therapeutic window over the full 30-day clinical implant duration.
Key Focus: Plasma-sprayed Hydroxyapatite (HA), porous titanium coating per ASTM F1147, bone ingrowth
Plasma spray deposition of osteoconductive ceramic and metallic porous coatings on titanium and cobalt-chromium joint replacement implants. Deposits synthetic Hydroxyapatite (Ca10(PO4)6(OH)2) and rough porous titanium coatings on femoral stems, acetabular hip cups, and spinal fusion cages to stimulate rapid bone ingrowth and long-term biological fixation.
Governing Consensus Standards
ASTM F1185 — Chemical purity and trace element limits for medical HA ASTM F1147 — Static tensile bond strength (>50 MPa) ASTM F1044 — Static shear adhesion of orthopedic coatings ISO 13779-2 — HA crystallinity, phase purity, and dissolution rate
Typical Deliverables
HA coated implant lots with ASTM F1147 tensile bond strength pull-off reports (>50 MPa)
X-ray diffraction (XRD) crystallinity and phase purity verification data (>62% crystalline)
Surface roughness (Ra / Rz) and porosity percentage analysis by optical stereology
Cleanroom bagged implants with complete powder lot traceability certificates
⇌
Off-the-shelf component cross-over:
Need surface micro-roughening before applying plasma-sprayed HA?
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to lincotek.com, which does not name Eurocoating S.p.A.) eurocoating.it, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH, IT.
what was checked ↗
· checked 2026-10-20
About Ceramic Thermal Spray & Hydroxyapatite (HA) Coating (Engineering Primer & Selection Guide)Expand ↓
Cementless joint implants rely on the patient’s bone locking directly into the prosthesis; synthetic Hydroxyapatite acts as a biological mineral scaffold that triggers direct bone apposition.
Plasma Spray Crystallinity Control
During plasma spraying, ceramic HA powder passes through a 10,000°C gas plume in milliseconds.
If the powder overheats, it decomposes into amorphous calcium phosphate, which dissolves too quickly in vivo; precise torch calibration maintains >65% crystalline HA for decade-long stability.
Controlled micro-abrasive grit blasting and mechanical surface texturing for orthopedic implants, dental fixtures, and catheter mandrels. Directs calibrated streams of high-purity aluminum oxide (Al2O3), zirconia, or bio-resorbable calcium phosphate media to achieve uniform, isotropic micro-roughness (Ra 1.5 to 6.0 µm) for osseointegration and coating adhesion promotion.
Governing Consensus Standards
ASTM F86 — Abrasive blasting media cleanliness and surface contamination limits ISO 4287 — Profile method parameters (Ra, Rz, Rmax) verification ISO 13485 — Process repeatability and embedded abrasive particle cleanliness
✓Site says it serves medical devices— found“help you build medical devices and bring” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “blast…” or “textur…” or “roughen…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485 Certified: Medical Devices Quality Management” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as ORCHID ORTHOPEDIC SOLUTIONS LANSING: FEI 3005852519; Contract Manufacturer; Holt, MI · FDA record ↗ · checked 2026-10-20
✓Site says it serves medical devices— found“Vapor Degreaser For Medical Device Instruments” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “blast…” or “textur…” or “roughen…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Micro-Grit Blasting & Surface Roughening (Engineering Primer & Selection Guide)Expand ↓
Machined dental implants and orthopedic joint stems are too smooth for initial biological mechanical interlock; micro-grit blasting creates microscopic pits that host osteoblast attachment.
Avoiding Residual Media Contamination
Ordinary abrasive grit embeds sharp alumina particles into soft titanium, which can detach in vivo and trigger inflammatory third-body wear.
Medical grit blasting utilizes soluble blast media or multi-stage acid etching/passivation cycles to completely dissolve or remove embedded foreign particles.
Controlled micro-dispensing and cross-linked baking of medical-grade silicone emulsions (polydimethylsiloxane / PDMS) on glass/polymer syringe barrels, auto-injector cartridges, rubber stoppers, and hypodermic needles. Minimizes needle penetration pain, eliminates plunger stick-slip (stiction), and guarantees smooth, low glide forces per ISO 7886-1.
Governing Consensus Standards
USP <1151> — Sub-visible silicone droplet limits and lubrication guidelines ISO 7886-1 — Plunger breakout force and dynamic extrusion glide force limits ISO 11040-4 — Barrel siliconization uniformity and particulate limits
Typical Deliverables
Syringe barrel friction force profile graphs (breakout force and dynamic glide force curves)
Sub-micron silicone layer thickness and coating weight distribution reports (XRF / gravimetric)
Sub-visible particulate analysis report per USP <788> / USP <1788>
✓Site states ISO 13485 certification— found“ISO 13485 certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT.
what was checked ↗
· checked 2026-10-20
–Site says it serves medical devices— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Syringe Barrel & Needle Silicone Lubrication (Engineering Primer & Selection Guide)Expand ↓
High-viscosity biologic drugs in auto-injectors require minimal plunger friction; without uniform nanometer-thick silicone lubrication, the spring drive will stall before delivering the full dose.
Baked-On vs. Free Liquid Silicone
Free liquid silicone oil can migrate into sensitive protein drugs, inducing therapeutic protein aggregation and foreign-body immune responses.
Thermal baked-on siliconization (curing reactive PDMS at 300°C) chemically cross-links the silicone to the glass surface, drastically reducing free sub-visible oil droplets.
Application of ultra-durable, pinhole-free non-stick PTFE and fluoropolymer release coatings on catheter manufacturing mandrels, guidewire core mandrels, and tipping dies. Applied to 304V stainless steel, Nitinol, and silver-plated copper wire down to 0.005″ OD to allow effortless demolding of reflowed Pebax, polyurethane, and braided catheter assemblies without internal lumen scuffing.
Governing Consensus Standards
ISO 13485 — Tool and fixture coating validation and process repeatability ASTM D3359 — PTFE coating cross-hatch adhesion verification ASTM B117 — Corrosion barrier durability
Typical Deliverables
Coated mandrels with laser micrometer OD uniformity and concentricity inspection logs
ASTM D3359 cross-hatch adhesion test certificate (Class 4B/5B rating)
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 404; x-hs-reason: 404 predicted at edge). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 404; x-hs-reason: 404 predicted at edge)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 404; x-hs-reason: 404 predicted at edge)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 404; x-hs-reason: 404 predicted at edge)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About PTFE Coating for Processing Mandrels (Engineering Primer & Selection Guide)Expand ↓
Demolding a 150 cm microcatheter from a bare stainless steel core mandrel will stretch and neck the polymer shaft; PTFE release coatings reduce pull forces by over 80%.
Coating Adhesion vs. Release Slip
The coating must adhere tenaciously to the metallic core wire while presenting a slippery, chemically inert outer surface to molten Pebax or Nylon during high-temperature reflow cycles.
Specialized chemical primers and high-temperature curing (380°C) lock the PTFE matrix to the metal, preventing coating flaking or particulate shedding into the device lumen.
Extractables & Leachables (E&L) Chemical Characterization
Key Focus: ISO 10993-18 chemical characterization, GC-MS/LC-MS/ICP-MS screening, AET calculation
Comprehensive chemical characterization and extractables & leachables (E&L) profiling for biocompatibility risk assessment. Conducts exaggerated, exhaustive, and simulated-use solvent extractions (polar, semi-polar, non-polar) analyzed via headspace GC-MS, GC-FID, LC-HRMS, and ICP-MS down to the Analytical Evaluation Threshold (AET) per ISO 10993-18.
Governing Consensus Standards
ISO 10993-18:2020 — Extraction protocols, analytical identification, and AET determination ISO 10993-17:2023 — Evaluating toxicological margins of safety (MoS) USP <1663> / <1664> — Standard pharmaceutical container testing
Typical Deliverables
Full ISO 10993-18 Chemical Characterization Study Report for FDA 510(k)/PMA filings
Comprehensive compound identification library match tables (CAS numbers, formulas, mass specs)
Analytical Evaluation Threshold (AET) mathematical derivation and justification memo
Semi-quantitative and quantitative concentration spreadsheets for all detected chemical species
⇌
Off-the-shelf component cross-over:
Need board-certified toxicologists (DABT) to evaluate the E&L compound list?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MO.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About Extractables & Leachables (E&L) Chemical Characterization (Engineering Primer & Selection Guide)Expand ↓
FDA no longer accepts animal biocompatibility tests alone; regulators require ISO 10993-18 analytical chemistry to identify every organic and inorganic chemical that could leach into a patient.
The Analytical Evaluation Threshold (AET)
The AET is the chemical concentration threshold below which an extractable compound is considered toxicologically negligible based on the Threshold of Toxicological Concern (TTC).
Any compound peak detected above the AET must be positively identified and handed over to a toxicologist for health risk evaluation.
Key Focus: ISO 10993-17:2023 toxicological risk assessment, Margin of Safety (MoS), DABT reports
Expert toxicological risk assessment (TRA) authoring for medical device biocompatibility evaluations. Board-certified toxicologists (DABT / ERT) evaluate chemical characterization extractables data against published toxicological databases to establish Tolerable Intake (TI) or Tolerable Exposure (TE) levels, calculating Margin of Safety (MoS) to justify waiving animal in-vivo studies.
Governing Consensus Standards
ISO 10993-17:2023 — Derivation of Tolerable Intake (TI) and Margin of Safety (MoS) ISO 10993-1 — General biological risk evaluation framework ICH Q3D — Permitted daily exposure (PDE) limits for elemental metals
Typical Deliverables
Comprehensive ISO 10993-17 Toxicological Risk Assessment Report signed by a DABT toxicologist
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
About Toxicological Risk Assessment & Margin of Safety (Engineering Primer & Selection Guide)Expand ↓
Under the updated ISO 10993-17:2023 standard, chemical risk assessment has become the preferred regulatory path to establish biological safety without unnecessary animal testing.
Calculating the Margin of Safety (MoS)
For every compound detected above the AET, a Tolerable Intake (TI) is derived from peer-reviewed animal No-Observed-Adverse-Effect-Levels (NOAEL) divided by uncertainty factors.
The Margin of Safety (MoS) compares this tolerable limit against the worst-case patient clinical exposure dose; an MoS > 1.0 proves acceptable biological safety to FDA and EU Notified Bodies.
Comprehensive MRI safety and compatibility testing for metallic and electronic medical implants in 1.5 Tesla and 3.0 Tesla MR environments. Quantifies magnetically induced displacement force (ASTM F2052), torque (ASTM F2213), radiofrequency (RF) heating at implant leads/electrodes (ASTM F2182), and image artifact size (ASTM F2119) to establish FDA "MR Conditional" labeling.
Governing Consensus Standards
ASTM F2052 — Deflection angle test under high magnetic spatial gradient fields ASTM F2182 — Fiber-optic fluoroptic temperature probes in gel phantoms ASTM F2213 — Torsional force evaluation on implantable devices ASTM F2119 — Artifact size characterization across pulse sequences FDA MRI Guidance 2021 — Mandatory labeling statements and RF safety limits
Typical Deliverables
Comprehensive ASTM MRI Safety Test Report for FDA 510(k)/PMA pre-market submissions
Fluoroptic RF heating temperature rise vs. time curves (°C rise over 15-minute scan)
Deflection angle photographs and calculated magnetic force vs. gravity comparisons
FDA-compliant draft "MR Conditional" package insert labeling text and warning symbols
⇌
Off-the-shelf component cross-over:
Need electromagnetic simulation to determine worst-case RF heating configurations?
✓Site states ISO 13485 certification— found“PJLA and certified to ISO 13485, and audited” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“certification services to medical device manufacturers looking” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “mri” or “magnetic resonance”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About MRI Safety & Compatibility Testing (Engineering Primer & Selection Guide)Expand ↓
Patients with implants undergo MRI scans daily; if an implant absorbs radiofrequency energy or torques in a magnetic field, it can burn surrounding tissue or dislodge painfully.
The Antenna Effect in Active Leads
Long conductive wires (such as pacemaker or deep brain stimulation leads) act as RF antennas during MRI scans, concentrating electric fields at the exposed distal tip.
ASTM F2182 testing uses fiber-optic temperature sensors placed in a physiological gel phantom to measure localized heating down to 0.1°C.
Accredited acoustic output measurement and beam characterization for diagnostic ultrasound, intravascular ultrasound (IVUS), and High-Intensity Focused Ultrasound (HIFU) therapy. Utilizes calibrated PVDF needle and membrane hydrophones in degassed water tanks to calculate Mechanical Index (MI), Thermal Index (TI), acoustic power, and beam intensity profiles per IEC 60601-2-37.
Governing Consensus Standards
IEC 60601-2-37 — Acoustic output limits, MI, and TI safety displays IEC 62127-1 — Hydrophone calibration and measurement protocols AIUM/NEMA UD 2 — Thermal and mechanical index calculations
Typical Deliverables
Accredited IEC 60601-2-37 Acoustic Output Test Report for FDA 510(k) submissions
Hydrophone 2D and 3D acoustic beam intensity profile plots (focal depth, beam width)
Mechanical Index (MI) and Thermal Index (TIS/TIB/TIC) calculation sheets
Total acoustic radiated power measurement reports (radiation force balance test)
⇌
Off-the-shelf component cross-over:
Need general IEC 60601-1 3rd edition electrical safety and dielectric testing?
✓Site states ISO 13485 certification— found“13485:2016 Certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CO.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “certification services (including ISO 13485 and MDSAP) and”, not counted (qualified: "certification services").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedrobots.txt disallows this URL. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (robots.txt disallows this URL). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (robots.txt disallows this URL). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (robots.txt disallows this URL). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Acoustic Output & Ultrasonic Transducer Characterization (Engineering Primer & Selection Guide)Expand ↓
Excessive acoustic energy can induce micro-bubble cavitation that tears biological cell membranes or cause localized thermal heating in fetal and ocular tissue.
Mechanical Index (MI) vs. Thermal Index (TI)
Mechanical Index (MI) quantifies the peak negative acoustic pressure to predict non-thermal bioeffects like inertial cavitation.
Thermal Index (TI) models the ratio of total acoustic power to the power required to raise tissue temperature by 1.0°C in soft tissue (TIS) or bone (TIB).
Regulatory sub-visible and visible particulate matter testing for intravascular devices, delivery catheters, syringes, and infusion sets. Quantifies extrinsic foreign particles (fibers, metal flakes, glass shards, rubber cores) and intrinsic shed particles using light obscuration (HIAC) and membrane filtration microscopy per USP <788>, USP <787>, and FDA Guidance for Intravascular Catheters.
Governing Consensus Standards
USP <788> — Standard light obscuration and microscopic limits for particles ≥10 µm and ≥25 µm USP <787> — Small volume testing protocols FDA Guidance 2021 — Simulated tracking and continuous flush particulate collection
Typical Deliverables
Accredited USP <788> Particulate Test Report documenting counts for ≥10 µm, ≥25 µm, and ≥50 µm particles
High-magnification microscopic photographs of collected membrane filters
FTIR micro-spectroscopy chemical identification of recovered particulate matter
Pass/fail compliance certification against FDA guidance release specifications
⇌
Off-the-shelf component cross-over:
Need to evaluate sub-visible silicone oil droplets shedding from syringe barrels?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
Option 3Medical Device Testing Services (MDTS)
mdtlabs.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)) mdtlabs.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About Sub-Visible Particulate Matter Testing (Engineering Primer & Selection Guide)Expand ↓
Particulates larger than 10 microns shed from catheters or syringe barrels can embolize in downstream capillary beds, causing strokes or pulmonary micro-infarctions.
Simulated Anatomical Tracking Flush
FDA guidance requires vascular devices to be tracked through a heated 37°C tortuous glass or silicone model while flushed with particle-free water.
All effluent fluid is collected and analyzed via light obscuration counters to ensure particles shed during navigation remain below regulatory safety thresholds.
Key Focus: ISO 10555-1 / ISO 10555-4 burst pressure, Rated Burst Pressure (RBP), high-flow testing
Mechanical verification testing for vascular catheters, high-pressure balloons, infusion manifolds, and luer fittings. Measures gravity and pressurized fluid flow rates (ml/min), pressure-vs-flow curves, static burst pressure, and statistical Rated Burst Pressure (RBP) per ISO 10555-1 and ISO 10555-4 using automated hydraulic pressure consoles up to 1,000 psi (68 bar).
Governing Consensus Standards
ISO 10555-1 — Catheter static burst pressure, flow rate, and power injection limits ISO 10555-4 — Balloon burst pressure, fatigue (10 cycles), and compliance curves ASTM F2079 — Radial pressure resistance and burst derivation
Typical Deliverables
Accredited ISO 10555 Mechanical Test Report for FDA 510(k) submissions
Pressure vs. time burst rupture graphs with recorded failure modes (shaft, balloon, hub)
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
Option 3Medical Device Testing Services (MDTS)
mdtlabs.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)) mdtlabs.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About Catheter Flow Rate & Static/Dynamic Burst Pressure (Engineering Primer & Selection Guide)Expand ↓
Contrast injection during angiography can subject catheter shafts to pressures exceeding 300 psi; a ruptured catheter in an artery releases plastic fragments and causes immediate vascular dissection.
Rated Burst Pressure (RBP) Derivation
RBP is not the mean burst pressure; it is a statistically calculated threshold below which 99.9% of all balloons are guaranteed not to burst with 95% confidence.
Testing requires testing minimum samples of 15 to 30 units to failure to establish normal or Weibull distribution parameters.
Electrochemical corrosion resistance testing of metallic vascular implants, orthopedic staples, and guidewires. Executes ASTM F2129 cyclic potentiodynamic polarization in de-aerated Phosphate Buffered Saline (PBS) or simulated bile at 37°C to measure resting potential (Er), breakdown potential (Eb), and repassivation potential (Ep), proving implants resist pitting corrosion in vivo.
Governing Consensus Standards
ASTM F2129 — Standard electrochemical cell test for stents and implants ASTM G5 — Electrochemical cell calibration ISO 10993-15 — Long-term metal ion release in biological systems
Typical Deliverables
Comprehensive ASTM F2129 Corrosion Test Report formatted for FDA pre-market submissions
Cyclic potentiodynamic polarization curves (log current density vs. potential plots)
Breakdown potential (Eb) and margin of safety (Eb - Er) statistical summaries
Pre- and post-corrosion scanning electron microscopy (SEM) surface photographs
⇌
Off-the-shelf component cross-over:
Need electropolishing or nitric/citric acid passivation to optimize breakdown potential?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: KY, NY.
what was checked ↗
· checked 2026-10-20
Option 3Medical Device Testing Services (MDTS)
mdtlabs.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)) mdtlabs.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About ASTM F2129 Electrochemical Cyclic Polarization Corrosion Testing (Engineering Primer & Selection Guide)Expand ↓
Corrosion of an implanted metallic stent releases toxic nickel or chromium ions into the bloodstream, precipitating localized tissue necrosis, restenosis, and catastrophic strut fracture.
Breakdown Potential (Eb) Margin of Safety
ASTM F2129 ramps electrical potential upward until the protective titanium or chromium oxide passive layer breaks down, indicated by an exponential spike in corrosion current.
FDA guidance typically expects the breakdown potential (Eb) to exceed +600 mV vs. SCE to ensure a robust margin of safety above natural physiological in-vivo redox potentials (+300 mV).
Coordinate Measuring Machine (CMM) & Multi-Sensor Video Metrology
Dimensional inspection, First Article Inspection (FAI per AS9102 / ISO 13485), and capability studies (Cp/Cpk) for complex medical implants, miniature gears, and surgical instruments. Employs multi-sensor video measuring systems, touch-trigger CMM probes, and white-light confocal sensors to measure fragile micro-machined and molded features with sub-micron measurement uncertainty.
Governing Consensus Standards
ISO 10360-2 — CMM measurement accuracy and repeatability verification AS9102 / ISO 13485 — Standard documentation for 100% drawing ballooning and dimensional records ASME Y14.5-2018 — Mathematical interpretation of measured geometric feature tolerances
Typical Deliverables
Complete First Article Inspection (FAI) package with ballooned engineering drawings
Detailed dimensional inspection spreadsheets with nominal, tolerance, and measured variance
Statistical process capability report (Cp, Cpk, Pp, Ppk histograms on critical dimensions)
NIST-traceable calibration certificates for all measuring machines and sensors used
⇌
Off-the-shelf component cross-over:
Need GD&T datum scheme optimization before setting up CMM inspection routines?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, NY.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MI.
what was checked ↗
· checked 2026-10-20
Option 3Carl Zeiss Industrial Metrology Services
zeiss.comWebsite did not answer as this company on 2026-10-20
📍 Maple Grove, MN / Wixom, MI
Sub-micron bridge CMM, optical 3D scanning, non-destructive industrial CT inspection
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but no page read names Carl Zeiss Metrology Services (domain may have changed hands)) zeiss.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, DE.
what was checked ↗
· checked 2026-10-20
About Coordinate Measuring Machine (CMM) & Multi-Sensor Video Metrology (Engineering Primer & Selection Guide)Expand ↓
Measuring a flexible 0.010″ silicone seal or miniature Nitinol stent strut with a physical contact caliper deforms the part and yields completely erroneous measurements.
Multi-Sensor Non-Contact Optical Metrology
Multi-sensor machines integrate high-resolution digital video cameras, non-contact laser autofocus, and ultra-low-force touch probes on a single gantry.
Key Focus: Custom Tyvek/foil cleanroom pouch converting, chevron peel, ISO 11607 seal qualification
High-speed cleanroom conversion and fabrication of custom sterile barrier pouches, header bags, and multi-layer moisture barrier pouches. Fabricates custom sizes from DuPont Tyvek (1073B, 1059B, 2FS), medical grade heat-sealable films, and high-barrier aluminum foils with chevron peel, corner thumb-notches, and validated heat seals per ISO 11607-1.
Governing Consensus Standards
ISO 11607-1 — Sterile barrier pouch permeability, microbial barrier, and seal strength ASTM F88 — Peel force testing (N/15mm or lbf/in) ASTM F1929 — Dye integrity testing
Typical Deliverables
Custom pouch lots with Certificate of Analysis (CoA) for seal strength and cleanroom particulate levels
✓Site states ISO 13485 certification— found“Amcor Winterbourne achieves ISO 13485:2016 certification, strengthening its” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, IE.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI.
what was checked ↗
· checked 2026-10-20
Option 3Rollprint Packaging Products (Pactur)
rollprint.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers) rollprint.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL.
what was checked ↗
· checked 2026-10-20
About Custom Cleanroom Medical Pouch Making (Engineering Primer & Selection Guide)Expand ↓
Stock pouches rarely fit complex catheter loops or bulky surgical retractors, causing pouch puncture during sterilization or transport transit.
Chevron vs. Straight-Seal Geometry
A chevron peel angle focuses the user opening force at a single apex point, initiating a smooth, fiber-free peel that prevents particulate shedding into the sterile surgical field.
Precision rotary converting dies maintain consistent 3-side seals, leaving the fourth end open for cleanroom product loading and final validation heat sealing.
Aseptic and cleanroom micro-volume liquid dispensing, formulation, and vial filling for in-vitro diagnostic (IVD) cartridges, lateral flow cassettes, and microfluidic lab-on-a-chip devices. Dispenses precise volumes (1 µL to 10 mL) of sensitive biological reagents, nucleic acid primers, enzymatic buffers, and lyophilized assay beads with automated screw-capping, induction sealing, and check-weighing.
Governing Consensus Standards
ISO 13485 — Production environment and automated dispensing validation ISO 14969 — Process validation for diagnostic filling 21 CFR 820 / cGMP — Enzyme stability, batch traceability, and fill volume verification
Typical Deliverables
Filled reagent lots with gravimetric fill-volume accuracy and precision reports (CV < 2%)
Torque verification logs for automated screw-cap closures and induction foil seals
Bioburden and endotoxin release testing certificates for filled aqueous buffers
Cold-chain temperature data logger records during cleanroom storage and refrigerated shipment
⇌
Off-the-shelf component cross-over:
Need microfluidic cartridges manufactured before cleanroom reagent filling?
✓Site says it serves medical devices— found“the right partner for medical device engineering” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: (“filling” or “fill-finish” or “fill finish” or “fill and finish”) and (“reagent…” or “liquid…” or “vial…” or “bottle…”). Found: reagent.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“through fully traceable, ISO 13485-certified processes that support” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, PA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN.
what was checked ↗
· checked 2026-10-20
About Cleanroom Micro-Dosing & Reagent Vial Filling (Engineering Primer & Selection Guide)Expand ↓
A 5% volume error in an RT-PCR diagnostic cartridge can shift cycle threshold (Ct) values and cause false negative pathogen calls; micro-dispensing demands positive-displacement ceramic pumps.
Positive-Displacement Ceramic Piston Dispensing
Peristaltic tubing fatigues over time, causing volume drift during long automated production runs.
Sapphire-hard ceramic rotary piston pumps maintain sub-microliter volumetric precision with zero seal wear or chemical leaching into sensitive biological assays.
Specialized barrier garment laundering, decontamination, and sterilization for ISO Class 4 to Class 8 medical device cleanrooms. Processes reusable cleanroom coveralls, hoods, boots, and frocks using reverse osmosis (RO) and deionized (DI) ultra-pure water with HEPA airflow drying, Helmke drum particulate counting per IEST-RP-CC003, and gamma irradiation sterilization.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, TX, VA.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: (“cleanroom…” or “clean room…”) and (“garment…” or “laundr…” or “apparel”). Found: garments.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
Option 3Aramark Cleanroom Services
aramarkuniform.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS certificate expired; plain http:// answers and redirects to vestis.com) aramarkuniform.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS certificate expired; plain http:// answers and redirects to vestis.com). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS certificate expired; plain http:// answers and redirects to vestis.com). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS certificate expired; plain http:// answers and redirects to vestis.com). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Cleanroom Garment Laundry & Decontamination (Engineering Primer & Selection Guide)Expand ↓
Humans are the primary source of contamination in a cleanroom, shedding up to 100,000 skin flakes per minute; high-filtration barrier garments trap these shed particles before they hit assembly tables.
Helmke Drum Particulate Testing
Garments are placed inside a rotating perforated drum while an optical particle counter samples the exhausted air.
Category I certification confirms that the laundered garment releases fewer than 1,200 particles (≥0.5 µm) per minute, qualifying it for ISO Class 4/5 surgical implant assembly.
Cleanroom kitting, multi-component collation, and sterile packaging of single-use procedural trays, surgical kits, and custom tubing sets. Assembles diverse surgical components (trocars, scalpel blades, needles, custom tubing manifolds, drapes, and gauze) into organized thermoformed blisters or pouches ready for terminal sterilization.
Governing Consensus Standards
ISO 13485 — Traceability and bill of materials reconciliation for multi-component kits ISO 11607-1 — Sterile barrier kit packaging 21 CFR 820.65 — Medical device kit component lot number tracking
Typical Deliverables
Assembled and sealed surgical kit lots with 100% Bill of Materials (BOM) reconciliation logs
Component lot traceability matrix linking all sub-tier manufacturer lot numbers
Sterile barrier seal strength and dye leak test verification records per ISO 11607
Outer shipper packaging with custom UDI barcode labeling ready for hospital distribution
⇌
Off-the-shelf component cross-over:
Need custom thermoformed PETG tray tooling and heat-seal validation?
✓Site states ISO 13485 certification— found“Certifications: ISO 13485:2016 Certified; FDA Registered; IMMEX /” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Viant Medical, LLC: FEI 3004976965; Contract Manufacturer, Complaint File Establishment, Manufacturer, Export-Only Manufacturer; Fort Wayne, IN · FDA record ↗ · site named on company’s own page ↗ · checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as MEDLINE INDUSTRIES, LP - Northfield: FEI 1417592; Specification Developer, Complaint File Establishment, Repackager/Relabeler; Northfield, IL · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
About Surgical Procedure Tray Kitting & Custom Sterile Tubing Sets (Engineering Primer & Selection Guide)Expand ↓
Operating room teams lose critical surgical time unwrapping individual instruments; pre-packaged procedural trays present all sterile components in the exact order of surgical execution.
BOM Reconciliation and Regulatory Kit Labeling
Under FDA 21 CFR 820, convenience kits require meticulous traceability linking the sterile pouch UDI barcode back to the individual sterilization records of every enclosed component.
Thermoformed tray layouts are ergonomically engineered to prevent sharp trocar tips from puncturing Tyvek lidding during shipping vibrations.
Key Focus: Vacuum potting, USP Class VI epoxy encapsulation, bubble-free hermetic sensor barrier
Cleanroom vacuum potting, dam-and-fill encapsulation, and conformal coating of miniature medical electronics, RF telemetry coils, and wireless biosensors. Dispenses USP Class VI and ISO 10993 compliant medical epoxies, silicones, and polyurethanes under high vacuum to eliminate microscopic air bubbles, preventing moisture ingress and electrical short circuits in bodily fluids.
Governing Consensus Standards
ISO 10993-5 — Biocompatibility of cured potting polymers IPC-CC-830 — Conformal coating dielectric and moisture barrier standards ISO 13485 — Automated metering, mixing, and dispensing process validation
Typical Deliverables
Potted electronic sensor sub-assemblies with acoustic microscopy (C-SAM) or X-ray void inspection reports
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: WI.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: WI.
what was checked ↗
· checked 2026-10-20
About Cleanroom Electronic Sensor Potting & Encapsulation (Engineering Primer & Selection Guide)Expand ↓
Warm saline in the human body is aggressive; a single microscopic void in potting resin creates a moisture trap that corrodes delicate electronics and shorts out telemetry within weeks.
Vacuum Meter-Mix-Dispensing (MMD)
Mixing two-part epoxies by hand whips air bubbles into the resin matrix that become fatal insulation weak points.
Automated vacuum meter-mix-dispensing draws the resin under 29 inHg vacuum, completely degassing both components before injecting the liquid into the housing cavity.
Specialized tooling design, carrier loading, and bobbin winding services for medical catheter braiding machines. Sets up 16-carrier, 32-carrier, and 64-carrier Maypole and rotary braiders with custom change gears, horn gears, and electronic wire tensioners to braid fine flat and round wires (304V stainless, Nitinol, tungsten, Kevlar) down to 0.0005″ diameter with exact picks per inch (PPI).
Governing Consensus Standards
ISO 10555-1 — Shaft torsional response, kinking, and tensile strength ASTM A313 — Braiding wire tensile tolerances and surface finish ISO 13485 — Braiding process control and PPI validation records
Typical Deliverables
Pre-wound medical braiding wire bobbins balanced for uniform tension (±5 grams)
Custom braider change-gear calculation sheet and mechanical gear train packages
Braided trial shaft mandrels with automated optical PPI verification logs
Wire lot metallurgical mill test certificates and elongation test records
⇌
Off-the-shelf component cross-over:
Need finished braided catheter shafts rather than raw braiding machine tooling?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: RI.
what was checked ↗
· checked 2026-10-20
Option 2Mayer Industries Inc.
mayerindustries.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) mayerindustries.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: SC.
what was checked ↗
· checked 2026-10-20
Option 3Steeger USA (Kuhne Group)
steegerusa.comWebsite did not answer as this company on 2026-10-20
📍 Spartanburg, SC
Medical catheter braiders, triaxial braiding, bobbin winders
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS certificate expired; plain http:// answers) steegerusa.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS certificate expired; plain http:// answers). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS certificate expired; plain http:// answers). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS certificate expired; plain http:// answers). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: SC.
what was checked ↗
· checked 2026-10-20
About Braiding Machine Tooling & Bobbin Carrier Loading (Engineering Primer & Selection Guide)Expand ↓
Uneven tension on a single carrier bobbin during a 16-wire braid causes loose loops and wire crosses, ruining the catheter surface during downstream lamination.
Tension Uniformity and Carrier Dynamics
Precision winding of flat wire (e.g. 0.0005″ × 0.003″) requires electronic closed-loop dancer arms to maintain constant winding pitch without wire twisting.
Calibrated carrier spring mechanisms ensure every wire meets the catheter core mandrel at the exact same braiding angle and tension.
Contract cleanroom manufacturing inside deep low-humidity dry rooms maintaining less than 1% Relative Humidity (dew points below -40°C to -60°C). Assembles moisture-sensitive medical devices including implantable lithium-ion batteries, moisture-curing adhesives, bioresorbable polymers (PLGA, PLA), and drug-device combination products that rapidly degrade in ambient humidity.
Governing Consensus Standards
ISO 14644-1 — Airborne particulate cleanliness within dry environments 21 CFR 211 / cGMP — Moisture-controlled drug handling ISO 13485 — Environmental monitoring and dry room validation
Typical Deliverables
Device assemblies manufactured under continuously recorded dry room conditions (dew point, RH, temp)
Karl Fischer titration moisture content analytical test reports on finished components
Desiccant hermetic pouch sealing verification records with moisture indicator cards
Lot environmental monitoring audit logs conforming to cGMP / ISO 13485
⇌
Off-the-shelf component cross-over:
Need custom implantable or wearable medical battery pack design and assembly?
✓Site says it serves medical devices— found“Commercial and Medical Markets ultralifecorp 2026-09-18T16:42:19-04:00” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “dry room…” or “dryroom…” or “low humidity” or “low-humidity”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NY.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“staff, safeguard critical medical equipment and promote” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “dry room…” or “dryroom…” or “low humidity” or “low-humidity”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, TX.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
About Low-Humidity Dry Room Assembly (<1% RH) (Engineering Primer & Selection Guide)Expand ↓
Exposure to ambient moisture (50% RH) triggers hydrolytic degradation in bioresorbable implants and explosive electrolyte reactions during lithium battery cell assembly within minutes.
Desiccant Wheel Dehumidification
Ordinary refrigeration chillers freeze and stop removing moisture below 40°F (dew point ~5°C).
Dry rooms utilize massive rotating silica gel desiccant wheels continuously regenerated with hot air, pulling indoor dew points down to -50°C (equivalent to 0.5% RH at 21°C).
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers) ebtec.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
Option 3Litron Laboratories & Services
litron.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to pacaero.com, which does not name Litron Laboratories & Services) litron.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About Contract Micro-Laser Sealing & Glovebox Assembly (Engineering Primer & Selection Guide)Expand ↓
Active implantable devices must remain completely sealed in the human body for 10+ years; body fluid ingress causes short circuits and rapid battery depletion.
Glovebox Controlled Inert Gas Sealing
Implant titanium cans are assembled inside sealed gloveboxes purged with dry argon or helium to eliminate oxygen and humidity.
Sealing the final seam with a pulsed laser traps a known concentration of helium inside, allowing fine helium mass spectrometry leak testing down to 10^-10 atm·cc/s.
Ethylene Oxide (EO/EtO) Cycle Development & Parametric Release
Key Focus: ISO 11135 EO cycle validation, overkill half-cycle method, EO/ECH residual testing
Contract Ethylene Oxide (EO / EtO) cycle development, microbiological validation, and commercial terminal sterilization processing for heat- and radiation-sensitive medical devices. Formulates half-cycle overkill validation protocols per ISO 11135, biological indicator (BI) spore challenges (B. atrophaeus 10^6), aeration time optimization, and EO/ECH residual gas testing per ISO 10993-7.
Governing Consensus Standards
ISO 11135:2014 — Cycle development, validation, and routine control requirements ISO 10993-7:2008 — Allowable patient limits for residual EO and ethylene chlorohydrin (ECH) AAMI TIR28 — Adopting new devices into existing validated EO cycles
Typical Deliverables
Comprehensive ISO 11135 EO Sterilization Validation Final Report for FDA 510(k)/PMA submissions
Fractional, half-cycle, and full-cycle biological indicator (BI) sterility test certificates (0/10 positive)
Gas chromatography EO and ECH residual analysis report per ISO 10993-7 (<4 mg/day patient limit)
Routine commercial Certificate of Sterility Release documentation for every processed pallet
⇌
Off-the-shelf component cross-over:
Need cross-modality comparison between Ethylene Oxide, Gamma, E-Beam, and VHP?
✓Site states ISO 13485 certification— found“544716 UKAS Multisite Certificate for ISO13485:2016 & EN” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Sterigenics US LLC: FEI 2011171; Contract Sterilizer, Export-Only Manufacturer; Los Angeles, CA · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “registered to the ISO 13485 Quality Standards, and”, not counted (qualified: "adheres").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ, PA.
what was checked ↗
· checked 2026-10-20
About Ethylene Oxide (EO/EtO) Cycle Development & Parametric Release (Engineering Primer & Selection Guide)Expand ↓
EO gas penetrates porous Tyvek packaging to kill resistant bacterial spores by DNA alkylation without melting low-durometer catheter plastics or damaging sensitive micro-electronics.
The Overkill Half-Cycle Method
ISO 11135 establishes sterility assurance levels (SAL 10^-6) by demonstrating a total 10^6 spore kill in half the nominal gas exposure time.
Doubling the exposure time for routine manufacturing guarantees that the probability of a non-sterile unit is less than one in a million.
Electron Beam (E-Beam) & Gamma Radiation Contract Processing
Key Focus: ISO 11137 radiation sterilization, high-energy Electron Beam (E-Beam), Cobalt-60 Gamma
High-throughput contract radiation sterilization processing using high-energy Electron Beam (E-Beam 10 MeV accelerators) and Cobalt-60 Gamma irradiation per ISO 11137. Provides rapid terminal sterilization for high-density orthopedic implants, surgical kits, single-use syringes, and IV sets with dose mapping, continuous dosimetry verification, and instant dosimetric release.
Governing Consensus Standards
ISO 11137-1 — Irradiation validation and process monitoring ISO 11137-2 — Method 1, Method 2, and VDmax verification methods ASTM E2303 — Dosimetry measurement protocols
✓Site states ISO 13485 certification— found“544716 UKAS Multisite Certificate for ISO13485:2016 & EN” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Sterigenics US LLC: FEI 3000215273; Contract Sterilizer, Export-Only Manufacturer; Gurnee, IL · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “registered to the ISO 13485 Quality Standards, and”, not counted (qualified: "adheres").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
About Electron Beam (E-Beam) & Gamma Radiation Contract Processing (Engineering Primer & Selection Guide)Expand ↓
Unlike gas sterilization which requires days of quarantine for toxic gas aeration, ionizing radiation sterilizes products in sealed boxes and permits immediate dosimetric release.
E-Beam vs. Gamma Penetration Kinetics
Gamma uses photons from decaying Cobalt-60 with deep penetration capability, ideal for dense, palletized metal implants.
E-Beam uses accelerated electrons delivered in seconds rather than hours, minimizing oxidative polymer chain scission and embrittlement in sensitive plastics.
Key Focus: Low-temperature VHP sterilization (ISO 22441:2022), zero toxic residuals, endoscopes/sensors
Low-temperature terminal sterilization using Vaporized Hydrogen Peroxide (VHP / VH2O2) under vacuum for sensitive electronic devices, CMOS camera sensors, battery-powered medical instruments, and prefilled biologic syringes. Operates at low temperatures (28°C to 50°C) with zero toxic chemical residuals (decomposing into pure water vapor and oxygen) per ISO 22441:2022.
Governing Consensus Standards
ISO 22441:2022 — Requirements for development, validation and routine control FDA ASCA Program — VHP terminal sterilization validation ISO 14937 — Characterization of new sterilizing agents
Typical Deliverables
Comprehensive ISO 22441:2022 VHP Cycle Validation Report for FDA pre-market submissions
Geobacillus stearothermophilus biological indicator (BI) challenge test verification logs
Electronic sensor and battery functionality verification reports after multi-cycle VHP exposure
Hydrogen peroxide residual vapor dissipation documentation (zero toxic chemical residue)
⇌
Off-the-shelf component cross-over:
Need an alternative to EO without toxic residuals or long aeration cycles?
✓Site says it serves medical devices— found“Medtech 360 Report.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “hydrogen peroxide” or “vhp” or “h2o2”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“+120 ISO13485:2016 certificates” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Stryker Sustainability Solutions: FEI 3009350690; Specification Developer, Single-Use Device Reprocessor; Tempe, AZ · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016 certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MD.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 9001 and ISO 13485 compliant quality system,”, not counted (qualified: "compliant").
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as STERIS Corporation: FEI 1923569; Complaint File Establishment, Manufacturer, Repackager/Relabeler, Specification Developer; Saint Louis, MO · FDA record ↗ · checked 2026-10-20
About Low-Temperature Vaporized Hydrogen Peroxide (VHP / VH2O2) Sterilization (Engineering Primer & Selection Guide)Expand ↓
Lithium battery packs explode in steam autoclaves, degrade under gamma radiation, and adsorb toxic EO gas; VHP sterilizes at room temperature without leaving a trace of chemical residue.
Dry Vapor vs. Condensation Phases
Deep vacuum cycles inject concentrated hydrogen peroxide vapor, maintaining vapor pressure below dew points to prevent liquid condensation on electronic circuitry.
At cycle completion, a catalytic converter breaks down all remaining peroxide molecules into harmless water vapor and oxygen, allowing immediate handling without degassing.
Regulatory bacterial endotoxin testing (BET) and non-endotoxin pyrogenicity testing for blood-contacting medical devices, implants, and combination products. Executes Limulus Amebocyte Lysate (LAL) and recombinant Factor C (rFC) assays per USP <85>, including kinetic chromogenic, kinetic turbidimetric, and gel-clot methods down to 0.005 EU/mL, and USP <151> rabbit pyrogen testing.
Governing Consensus Standards
USP <85> — Gel-clot, turbidimetric, and chromogenic quantitative assays ANSI/AAMI ST72 — Medical device extraction and batch release endotoxin limits (20 EU/device or 2.15 EU/device for intrathecal) USP <151> — In vivo rabbit pyrogen challenge for non-endotoxin pyrogens
Typical Deliverables
Accredited USP <85> Bacterial Endotoxin Test Report with quantitative EU/device calculations
✓Site states ISO 13485 certification— found“I.S. EN ISO 13485:2016” · source ↗ · certificate ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as ASSOCIATES OF CAPE COD, INC.: FEI 1219145; Manufacturer; E Falmouth, MA · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, SC.
what was checked ↗
· checked 2026-10-20
About Bacterial Endotoxin Testing (LAL) & Pyrogenicity (Engineering Primer & Selection Guide)Expand ↓
A medical device can be 100% sterile (zero living bacteria) yet still kill a patient; lipopolysaccharide fragments (endotoxins) from dead Gram-negative bacterial cell walls cause severe septic shock.
FDA Device Endotoxin Safety Limits
FDA and AAMI ST72 enforce strict limits: devices contacting cardiovascular or lymphatic blood must not exceed 20 EU/device (Endotoxin Units).
Devices contacting cerebrospinal fluid (intrathecal catheters, neurological implants) have a tenfold tighter limit: 2.15 EU/device to prevent life-threatening aseptic meningitis.
Conjugate heat transfer simulation and thermal management engineering for high-power surgical consoles, RF/microwave ablation generators, and wearable electronics. Models internal conduction, forced-air convection, and heat pipes to maintain patient-applied part touch temperatures strictly below IEC 60601-1 Clause 11 safety thresholds (41°C–48°C).
Governing Consensus Standards
IEC 60601-1 Clause 11 — Allowable maximum surface contact temperatures for operators and patients ISO 14971 — Thermal hazard and tissue burn risk mitigations ASTM F2172 — Fluid heating control and overshoot prevention
Typical Deliverables
Comprehensive Thermal CFD simulation report with 3D temperature contour heatmaps
IEC 60601-1 touch temperature compliance margins under 40°C ambient room conditions
Optimized extruded/skived heat sink and heat pipe CAD models (.STEP)
Benchtop thermal chamber thermocouple verification test reports
⇌
Off-the-shelf component cross-over:
Need chassis ventilation grilles and thermal interface materials (TIM)?
✓Site says it serves medical devices— found“Wearable medical devices include biosensors and monitoring” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “thermal simulat…” or “thermal model…” or “thermal analys…” or “cfd” or “computational fluid dynamics”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as BOYD CORPORATION: FEI 3021090069; Contract Manufacturer; Juarez Chihuahua, MX · FDA record ↗ · site named on company’s own page ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH, TX.
what was checked ↗
· checked 2026-10-20
About Medical Thermal Simulation & Heat Sink Design (Engineering Primer & Selection Guide)Expand ↓
IEC 60601-1 limits applied part temperatures to 43°C during continuous contact; thermal CFD modeling prevents expensive console redesigns late in verification testing.
Touch Temperature Safety Thresholds
Applied parts in contact with patient skin must not exceed 41°C without clinical justification, while operator handles are capped at 48°C.
Conjugate heat transfer modeling solves air fluid dynamics and solid conduction simultaneously to eliminate internal hot spots.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, DK.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedrobots.txt disallows this URL. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (robots.txt disallows this URL). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (robots.txt disallows this URL). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (robots.txt disallows this URL). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
About Piezoelectric Transducer Modeling & FEA (Engineering Primer & Selection Guide)Expand ↓
Acoustic impedance mismatch between PZT ceramics (30 MRayl) and human tissue (1.5 MRayl) reflects 80% of acoustic energy; modeling layered matching transformers maximizes transmission efficiency.
Quarter-Wave Matching Layer Optimization
Intermediate matching layers made of polymer resins loaded with ceramic micro-powders bridge the impedance gap.
Finite element modeling tunes layer thickness to exactly one-quarter acoustic wavelength, eliminating destructive phase cancellation.
Key Focus: Implant antenna design, MedRadio/MICS 402 MHz, body-tissue SAR simulation, BLE antennas
Electromagnetic simulation and physical prototyping of miniature embedded and implantable antennas for active medical devices. Designs high-efficiency serpentine, helical, and loop antennas for MedRadio (401–406 MHz), ISM (2.4 GHz BLE), and NFC telemetry inside titanium enclosures or silicone headers, with Specific Absorption Rate (SAR) verification in anatomical body models.
Governing Consensus Standards
FCC Part 95 Subpart I — Frequency allocation, bandwidth, and ERP emission limits IEEE C95.1 — Specific Absorption Rate (SAR) dosimetry limits (1.6 W/kg) IEC 60601-1-2 — Radiated emissions and immunity requirements
Typical Deliverables
Ansys HFSS / CST Studio electromagnetic simulation package with 3D radiation patterns
Return loss (S11) and voltage standing wave ratio (VSWR) impedance matching curves
Specific Absorption Rate (SAR) human body tissue compliance reports for FCC/FDA filings
Prototyped flexible polyimide or stamped titanium antennas with coaxial test pigtails
⇌
Off-the-shelf component cross-over:
Need formal radiated emissions, immunity, and AAMI TIR69 coexistence testing?
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but the domain is parked or for sale) antennaconsulting.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: TX.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, DE.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, IE.
what was checked ↗
· checked 2026-10-20
About Medical Implant & Telemetry Antenna Engineering (Engineering Primer & Selection Guide)Expand ↓
Biological human tissue has high relative permittivity (er ~ 50) and conductivity, which detunes free-space antennas and absorbs up to 90% of emitted radiofrequency energy.
Human Body Loading and Dielectric Compensation
Antennas inside the body must be designed to resonate while immersed in conductive saline and fat/muscle layers rather than open air.
Electromagnetic solvers (HFSS) simulate inhomogeneous tissue phantoms to ensure radiation efficiency and stay strictly below FDA SAR thermal limits.
✓Site says it serves medical devices— found“Medical Catheter & Medical Device Tubing Manufacturing” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “prototyp…” and (“mechanism…” or “actuat…” or “mechanical design”). Found: prototyping.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“control and certifications include ISO 13485:2016, defining the” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“Precision electric drives for medical technology.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “prototyp…” and (“mechanism…” or “actuat…” or “mechanical design”). Found: prototypes.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“SN EN ISO 13485 Medical Products” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, CH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL, DE.
what was checked ↗
· checked 2026-10-20
About Steerable Articulation & Micro-Drive Prototyping (Engineering Primer & Selection Guide)Expand ↓
Minimally invasive surgical instruments must navigate tight 90-degree anatomical turns; custom articulation wrists translate remote doctor movements into smooth distal tip deflection.
Friction Losses in Long Pull-Wire Lumens
Friction builds exponentially as catheters curve through anatomy (the capstan effect), degrading surgeon tactile feedback.
PTFE-lined lumen routing and laser-slotted Nitinol backbone joints prevent cable bind-up and ensure repeatable angular control.
Flex and Rigid-Flex PCB Prototyping for Catheter Shafts
Rapid prototyping of ultra-thin flexible and rigid-flex printed circuit boards (FPC) designed for extreme miniaturization inside catheter shafts, endoscopes, and implantable headers. Fabricates single, double, and multi-layer flex circuits on adhesiveless polyimide films (12.5 µm to 25 µm substrate) with trace/space geometries down to 25 µm and gold-plated sensor pads.
Governing Consensus Standards
IPC-6013 Class 3 — High-reliability medical electronics standards IPC-A-600 — Visual acceptance criteria and microsection criteria ISO 13485 — Process controls and material traceability
Typical Deliverables
Turnkey prototype flex circuits with electrical continuity and short test reports (100% netlist test)
Microsection cross-sectional plating thickness and dielectric layer verification reports
IPC-6013 Class 3 Certificate of Conformance with material lot traceability
Individual laser-excised circuits in vacuum antistatic cleanroom packaging
⇌
Off-the-shelf component cross-over:
Need miniature SMT components placed and reflowed onto your custom flex circuits?
✓Site states ISO 13485 certification— found“The 13485:2016 certification demonstrates the fact that Tech” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as TECH-ETCH, INC.: FEI 1000297541; Contract Manufacturer; Plymouth, MA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“facilities are certified to ISO 13485 and ISO” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Flex and Rigid-Flex PCB Prototyping for Catheter Shafts (Engineering Primer & Selection Guide)Expand ↓
Running dozens of individual discrete wires down a 4 French catheter shaft creates an unmanageable bundle; thin polyimide flex circuits lay flat against the wall, preserving working lumen space.
Adhesiveless Polyimide vs. Adhesive Layers
Adhesive-bonded copper flex circuits delaminate and outgas moisture when repeatedly flexed or autoclaved.
Adhesiveless cast polyimide provides superior thermal stability, lower moisture absorption, and extreme bend radii down to 2x board thickness without copper fatigue.
Medical Fiber Optic Cable & Beam Delivery Prototyping
Custom engineering, polishing, and termination of medical optical fiber assemblies for laser surgery (Holmium/Thulium/CO2), photodynamic therapy, and spectroscopic sensing. Fabricates fused silica fibers (core sizes 150 µm to 1000 µm) with custom cleaved, angled, or ball-shaped distal tips, side-firing quartz caps, biocompatible ETFE jackets, and medical SMA905/FC connectors.
Governing Consensus Standards
IEC 60825-1 — Laser radiation safety and beam delivery containment ISO 13485 — Critical process controls for fiber cleaving and termination ASTM F1089 — Autoclave durability of optical connector assemblies
Typical Deliverables
Finished optical fiber cable prototypes with insertion loss and transmission efficiency reports (>92%)
Interferometric end-face geometry inspection images (radius of curvature, fiber undercut/protrusion)
High-power laser burst damage threshold test certification (50W+ pulsed test)
Individual cleanroom sealed pouches with protective ferrule dust caps
⇌
Off-the-shelf component cross-over:
Need coupling lens systems designed to focus your laser diode beam into fiber cores?
✓Site states ISO 13485 certification— found“CeramOptec GmbH: EN ISO 13485:2016 [ >> pdf” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as CERAMOPTEC GMBH: FEI 3003340844; Manufacturer; Bonn North Rhine-Westphalia, DE · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as POLYMICRO TECHNOLOGIES, A SUBSIDIARY OF MOLEX: FEI 3001222017; Contract Manufacturer; Phoenix, AZ · FDA record ↗ · checked 2026-10-20
Option 3LEONI Fiber Optics (BizLink)
leoni-fiber-optics.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) leoni-fiber-optics.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: VA, DE.
what was checked ↗
· checked 2026-10-20
About Medical Fiber Optic Cable & Beam Delivery Prototyping (Engineering Primer & Selection Guide)Expand ↓
Surgical lasers delivering 30-watt pulses through a 200-micron fiber will vaporize the fiber face if an air pocket or adhesive bubble exists at the connector interface.
High-Power Laser Termination Architecture
Traditional telecommunications epoxy connectors burn instantly under surgical laser powers.
Medical laser fibers use cantilevered bare-glass terminations or laser-fused quartz end-caps that remove adhesive entirely from the high-intensity optical beam path.
✓Site states ISO 13485 certification— found“US-based contract manufacturer to receive ISO 13485 registration.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as NORMAN NOBLE, INC.: FEI 3002755653; Contract Manufacturer; Highland Heights, OH · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“to DIN EN ISO 13485 (replacing certification according” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: DE.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH.
what was checked ↗
· checked 2026-10-20
About Continuous Spiral & Pitch-Variation Hypotube Laser Cutting (Engineering Primer & Selection Guide)Expand ↓
Solid metal tubes kink when bent around tight aortic arches; cutting a continuous variable-pitch spiral transforms a rigid hypodermic tube into a highly flexible, torqueable catheter shaft.
Progressive Pitch Flexibility Grading
Tight pitch spirals at the distal tip provide extreme floppiness and atraumatic navigation in delicate vessels.
Gradually widening the pitch toward the proximal handle preserves column pushability and 1:1 torque responsiveness for the interventionalist.
Multi-Axis Swiss CNC Turning for Bone Screws & Dental Abutments
Ultra-precision multi-axis Swiss CNC micro-turning and specialized thread whirling for titanium and cobalt-chrome implants. Manufactures complex cannulated cortical and cancellous bone screws, dental implant abutments, polyaxial pedicle screws, and miniature articulated bone anchors with runout tolerances below 0.0001″ (2.5 µm).
Governing Consensus Standards
ISO 5835 — Surgical bone screw dimensions, thread forms, and mechanical tolerances ASTM F543 — Torsional yield, insertion torque, and pullout strength ISO 13485 — Traceability and validated CNC machining processes
Typical Deliverables
First Article Inspection (FAI) reports with 100% thread profile optical comparator verification
Cannulation concentricity and runout inspection logs (laser gauge verification)
ASTM F543 insertion and torsional yield test verification data
Ultrasonically passivated and laser-marked bone screws in cleanroom packaging
⇌
Off-the-shelf component cross-over:
Need general CNC turning for non-orthopedic surgical instruments or handles?
✓Site states ISO 13485 certification— found“System is certified to ISO 13485:2016 and compliant” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Cadence Inc.: FEI 3009266751; Contract Manufacturer; Staunton, VA · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 and FDA QSR compliant.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Tegra Medical: FEI 3008647423; Contract Manufacturer; Hernando, MS · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About Multi-Axis Swiss CNC Turning for Bone Screws & Dental Abutments (Engineering Primer & Selection Guide)Expand ↓
Single-point turning of high-pitch titanium bone screw threads bends slender bar stock; high-speed thread whirling cuts the entire thread geometry in one pass without stock deflection.
Cannulation and Runout Control
Cannulated bone screws require a continuous hollow bore through the center for guidewire insertion during orthopedic trauma surgery.
Deep-hole micro-gun-drilling inside a Swiss lathe maintains drill runout below 0.001″ over 100 mm screw lengths, preventing sidewall blowout.
Additive Manufacturing of Trabecular Porous Titanium Implants
Direct metal additive manufacturing of patient-specific and standard orthopedic implants using Electron Beam Melting (EBM) and Laser Powder Bed Fusion (LPBF). Produces complex trabecular porous titanium lattice structures with calibrated pore sizes (300 µm to 700 µm) and 60%–75% interconnected porosity to mimic cancellous bone and maximize biological osseointegration.
Governing Consensus Standards
ASTM F3001 — Standard metallurgical and tensile specifications ASTM F1147 — Static tensile bond strength of additive lattices ISO 13485 — Powder reuse validation and cleanroom post-processing
Typical Deliverables
3D printed porous implant lots with micro-CT scan reports verifying internal pore interconnectivity
ASTM F3001 tensile, yield, and elongation mechanical test verification data
Destructive cross-sectional metallographic micrographs showing full powder fusion
Post-print vacuum hot isostatic pressing (HIP) and cleanroom vacuum packaging certificates
⇌
Off-the-shelf component cross-over:
Need rapid plastic SLA/SLS proof-of-concept models before printing in implant metal?
✓Site states ISO 13485 certification— found“3D Systems has world-class, FDA-registered, ISO 13485-certified facilities.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as MEDICAL MODELING - A 3D SYSTEMS COMPANY: FEI 3003142829; Contract Manufacturer, Manufacturer; Littleton, CO · FDA record ↗ · checked 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to lincotek.com, which does not name Eurocoating S.p.A.) eurocoating.it, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH, IT.
what was checked ↗
· checked 2026-10-20
About Additive Manufacturing of Trabecular Porous Titanium Implants (Engineering Primer & Selection Guide)Expand ↓
Machined solid metal implants have a high elastic modulus (~110 GPa) that causes stress shielding and bone resorption; 3D printed porous lattices match natural cancellous bone modulus (~2–4 GPa).
Depowdering and Hot Isostatic Pressing (HIP)
Trapped un-sintered metallic powder within internal pores can dislodge in vivo; specialized ultrasonic and acoustic resonant cleaning ensures 100% loose powder removal.
Hot Isostatic Pressing (HIP at 920°C / 100 MPa) closes microscopic internal voids, restoring fatigue endurance to exceed wrought titanium specs.
Platinum-Cure Medical Silicone Multi-Lumen Tubing Extrusion
Continuous extrusion and vulcanization of ultra-pure platinum-cured liquid silicone rubber (LSR) and high-consistency silicone rubber (HCR). Extrudes kink-resistant multi-lumen profiles, peristaltic pump tubing with ultra-low spallation, wound drainage profiles (fluted, channel), and co-extruded barium sulfate radiopaque lines per USP Class VI and ISO 10993.
Governing Consensus Standards
USP <88> Class VI — Medical grade implantable silicone biocompatibility ISO 10993-5 — Cytotoxicity testing on platinum-cure silicone ISO 13485 — Continuous laser gauging and cleanroom extrusion validation
Typical Deliverables
Silicone tubing coils with continuous dual-axis laser micrometer OD/ID inspection data sheets
Peristaltic pump pump-life and spallation rate benchmark test reports
Tensile, elongation, and tear strength certification per ASTM D412 and ASTM D624
Post-cure degassing verification certificates in cleanroom polybags
⇌
Off-the-shelf component cross-over:
Need molded silicone catheter balloon tips, manifolds, or grommets?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 11 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Trelleborg Sealing Solutions Litchfield: FEI 3004126422; Contract Manufacturer; Litchfield, MN · FDA record ↗ · checked 2026-10-20
About Platinum-Cure Medical Silicone Multi-Lumen Tubing Extrusion (Engineering Primer & Selection Guide)Expand ↓
Peroxide-cured silicone releases acidic volatile byproducts that can leach into intravenous drugs; platinum-addition cured silicone cures cleanly with zero extractable chemical residues.
Vertical Hot-Air Vulcanization Towers
Soft, unvulcanized silicone collapses under its own weight if extruded horizontally on conventional conveyor belts.
Vertical vulcanization towers extrude tubing upward into high-temperature ovens, curing the circular lumen in free air without flat spots.
Ultrasonic Micro-Machining of Zirconia & Alumina Ceramics
Key Focus: Ultrasonic machining (USM), micro-drilling technical ceramics, zero micro-cracking
Rotary ultrasonic machining (RUM) and ultrasonic vibration-assisted micro-drilling of extremely hard, brittle medical ceramics and technical crystals. Machines complex geometries, micro-holes down to 50 µm, and threads in Yttria-stabilized Tetragonal Zirconia Polycrystal (Y-TZP), high-purity Alumina (Al2O3), and synthetic sapphire with zero micro-fractures and mirror surface finishes.
Governing Consensus Standards
ISO 13356 — Purity, microstructure, and flexural strength ISO 6474-1 — Alumina ceramic implant requirements ISO 13485 — Specialized hard-material process validation
✓Site says it serves medical devices— found“opening of CeramTec’s medical technology facility in” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “ceramic…” and (“machining” or “machined” or “grinding”). Found: ceramics.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“CeramTec is certified to ISO 13485 for medical” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as CERAMTEC GmbH Medical Products Division: FEI 3002806653; Contract Manufacturer, Contract Sterilizer; Plochingen Baden-Wurttemberg, DE · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“U.S.A at our ISO 13485 certified facility in” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CO.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
About Ultrasonic Micro-Machining of Zirconia & Alumina Ceramics (Engineering Primer & Selection Guide)Expand ↓
Conventional carbide drills shatter brittle technical ceramics due to severe contact shear stress; ultrasonic cutting tools vibrate at 20 kHz, hammering microscopic diamond abrasive particles that erode material cleanly.
Preventing Subsurface Micro-Cracking
Mechanical grinding induces micro-cracks in zirconia that slowly propagate over millions of load cycles in vivo, risking sudden catastrophic ceramic fracture.
Ultrasonic vibration reduces machining cutting forces by over 60%, leaving defect-free polished edges that preserve the native 1,000 MPa flexural strength of Y-TZP zirconia.
CNC precision bending and rotary draw forming of miniature stainless steel and Nitinol hypodermic tubing (Gauge 10 to Gauge 32). Delivers repeatable compound 3D curves, tight-radius bends (CLR < 1.5x OD), S-curves, and helical coils without tube flattening, ovalization, or internal lumen necking for endoscopic tools, surgical needles, and shaped introducer sleeves.
Governing Consensus Standards
ISO 9626 — Tubing ductility, stiffness, and breakage limits during bending ISO 11070 — Pre-shaped curve retention and lumen verification ISO 13485 — CNC bending tool qualification and angle inspection
Typical Deliverables
Bended tubing lots with optical comparator and 3D CMM compound angle verification reports
✓Site states ISO 13485 certification— found“company (also ISO 9001/13485 certified ), our manufacturing” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as VITA NEEDLE CO.: FEI 1213680; Contract Manufacturer, Manufacturer; Needham, MA · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“our certifications, including ISO 9001 and ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About CNC Micro-Tubing Bending & Custom Anatomical Coiling (Engineering Primer & Selection Guide)Expand ↓
Bending small thin-wall tubing without an internal support causes the outer wall to stretch thin and the inner throat to buckle into a kink, pinching the working channel.
Internal Flexible Mandrel Support
Precision rotary draw bending inserts flexible ball mandrels or low-melting-point eutectic alloys inside the tube lumen during the bend cycle.
This maintains strict internal roundness (less than 8% cross-sectional ovalization) so optical fibers or biopsy wires pass through smoothly.
Burr-Free Electrochemical Grinding (ECG) for Hypodermic Tubing
Burr-free, stress-free electrochemical grinding (ECG) of thin-wall stainless steel, Nitinol, and titanium hypodermic tubing. Combines electrochemical deplating (90% of material removal) with light abrasive grinding (10%) to cut compound needle bevels, lancet points, cross-holes, and longitudinal slots with zero entrance/exit burrs and zero metallurgical burn.
Governing Consensus Standards
ISO 7864 — Point geometry, bevel burr-free limits, and cleanliness ISO 9626 — Tubing metallurgical requirements ISO 13485 — Electrolytic grinding bath controls and validation
Typical Deliverables
ECG ground needle cannulae with optical microscope bevel angle and burr inspection reports (zero burrs at 50x)
Cross-sectional microstructural metallographic analysis verifying absence of thermal recast layer
Needle penetration force test curves into polyurethane substrate membranes
Passivated, ultrasonically cleaned, and cleanroom bagged cannulae lots
⇌
Off-the-shelf component cross-over:
Need solid wire taper grinding rather than hollow tubular needle beveling?
✓Site states ISO 13485 certification— found“System is certified to ISO 13485:2016 and compliant” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Cadence Inc.: FEI 3009266751; Contract Manufacturer; Staunton, VA · FDA record ↗ · checked 2026-10-20
✓Site says it serves medical devices— found“Is Your Medical Device Sharp Enough?” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “electrochemical grind…” or “electro-chemical grind…” or “ecg”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 and FDA QSR compliant.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Tegra Medical - Franklin, MA: FEI 3002758924; Contract Manufacturer; Franklin, MA · FDA record ↗ · checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 7 pages read)
what was checked ↗
· checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “electrochemical grind…” or “electro-chemical grind…” or “ecg”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 7 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI.
what was checked ↗
· checked 2026-10-20
About Burr-Free Electrochemical Grinding (ECG) for Hypodermic Tubing (Engineering Primer & Selection Guide)Expand ↓
Abrasive grinding wheels push a mechanical burr into the inner lumen of small hypodermic tubes, blocking fluid flow and tearing delicate tissue during clinical puncture.
Cold Electrochemical Dissolution
In ECG, the workpiece is the positive anode and the conductive grinding wheel is the negative cathode in a salt electrolyte bath.
Direct current electrolytically dissolves the metal atoms before the abrasive grain physically touches them, producing perfectly sharp, 100% burr-free bevels without localized heating.
Single-Point Diamond Turning (SPDT) for Medical Optics
Ultra-precision Single-Point Diamond Turning (SPDT) and deterministic micro-milling of optical surfaces using natural diamond cutting tools. Manufactures high-precision aspheric, toric, and diffractive optical lenses, intraocular lens (IOL) injection mold inserts, endoscopic mirrors, and germanium infrared windows with sub-nanometer surface roughness (Ra < 2 nm) and sub-micron form accuracy without secondary polishing.
Governing Consensus Standards
ISO 10110 — Surface form tolerance and surface imperfection limits ISO 11979-2 — IOL optical resolution, dioptric power, and MTF specs ISO 13485 — Ultra-precision environmental and machine calibration controls
Typical Deliverables
Diamond turned optical elements with white-light interferometer 3D surface topography reports (Ra < 2 nm)
Laser interferometer form error wavefront error maps (PV form error < 0.15 µm)
Modulation Transfer Function (MTF) optical performance test certification
Ultra-clean lens packaging in vacuum gel-packs inside cleanroom containers
⇌
Off-the-shelf component cross-over:
Need complete optical lens barrel assembly and laser beam alignment?
✓Site says it serves medical devices— found“Current Trends in Medical Device Imaging Webinar” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “diamond turn…” or “single point” or “spdt” or “diamond-turn…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“QSR Compliant, ISO 9001 and ISO 13485 registered.” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as PRECISION OPTICS CORP.: FEI 1000120916; Contract Manufacturer; Gardner, MA · FDA record ↗ · checked 2026-10-20
✓Site says it serves medical devices— found“industries such as medical devices, diagnostics, defense,” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “diamond turn…” or “single point” or “spdt” or “diamond-turn…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“is ISO 13485:2016 and ISO 9001:2015 certified, holds” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 7 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL, LV.
what was checked ↗
· checked 2026-10-20
About Single-Point Diamond Turning (SPDT) for Medical Optics (Engineering Primer & Selection Guide)Expand ↓
Conventional optical grinding and polishing cannot produce complex diffractive rings or off-axis aspheric surfaces required for multifocal intraocular lenses; SPDT carves them deterministically.
Nanometer-Scale Material Shearing
SPDT machines utilize air-bearing spindles with less than 20 nanometers of runout and single-crystal monocrystalline natural diamond cutting edges.
The diamond tool shears ductile chips on a nanometer scale, producing mirror-smooth optical finishes directly from the lathe without orange peel or edge rolloff.
Polymer Hot Embossing & Nano-Imprinting for Lab-on-a-Chip
Key Focus: Hot embossing microfluidics, sub-micron channels in COP/COC, low-autofluorescence chips
High-precision thermal hot embossing and nano-imprint lithography for microfluidic diagnostic consumables, point-of-care test cartridges, and DNA sequencing flow cells. Replicates sub-micron channels, pillar arrays, and capillary stop valves in optical-grade Cyclic Olefin Polymer (COP / COC), PMMA, and polycarbonate from precision silicon or electroformed nickel stampers.
Governing Consensus Standards
ISO 13485 — Micro-fabrication process controls and cleanroom replication ISO 10993-5 — Biocompatibility of microfluidic cartridge substrates ASTM D1003 — Optical clarity for fluorescence microscopy
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 9001 & 13485 certified.” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, DE.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “IATF 16949, or ISO 13485 certification, depending on”, not counted (a service offered to clients).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: GA, JP.
what was checked ↗
· checked 2026-10-20
About Polymer Hot Embossing & Nano-Imprinting for Lab-on-a-Chip (Engineering Primer & Selection Guide)Expand ↓
Hot embossing heats polymer sheets uniformly above their glass transition temperature (Tg) before slowly pressing a nickel master stamper under vacuum.
Because the plastic flows without high shear velocities, residual stress is virtually zero, delivering pristine optical clarity for fluorescent DNA detection.
Medical Slush & Rotational Molding for Inflatable Cuffs
Specialized slush molding, rotational dip molding, and rotational casting of seamless, ultra-thin elastomeric bladders and inflatable cuffs. Produces low-pressure high-volume (HVLP) endotracheal tube cuffs, tracheostomy balloons, surgical irrigation bladders, and vascular tourniquet sleeves from medical polyurethane (TPU) down to 5–15 µm wall thickness with zero seam flash.
Governing Consensus Standards
ISO 5361 — Cuff diameter, compliance, and tracheal wall pressure limits ISO 10993-5 — Mucosal contact biocompatibility ISO 13485 — Slush molding process controls and leak challenge testing
Typical Deliverables
Rotomolded cuffs with optical comparator micro-thickness inspection reports (5 to 15 µm ± 2 µm)
Pressure-volume inflation compliance curves (tracheal sealing pressure at <25 cmH2O)
100% helium or submerged air-pressure bubble leak test verification records
Cleanroom bagged and lot-certified bladders ready for catheter shaft solvent bonding
⇌
Off-the-shelf component cross-over:
Need high-pressure PET angioplasty balloons rather than ultra-thin soft cuffs?
✓Site says it serves medical devices— found“Medical Catheter & Medical Device Tubing Manufacturing” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “rotational mold…” or “rotomold…” or “roto-mold…” or “slush mold…” or “dip mold…” or “dip-mold…” or “rotational mould…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“control and certifications include ISO 13485:2016, defining the” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“Delivering advanced cardiovascular surgical devices—including myocardial protection” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “rotational mold…” or “rotomold…” or “roto-mold…” or “slush mold…” or “dip mold…” or “dip-mold…” or “rotational mould…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485 and 14971 Risk Management certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 1 page read)
what was checked ↗
· checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “rotational mold…” or “rotomold…” or “roto-mold…” or “slush mold…” or “dip mold…” or “dip-mold…” or “rotational mould…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 1 page read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Medical Slush & Rotational Molding for Inflatable Cuffs (Engineering Primer & Selection Guide)Expand ↓
Conventional blow-molded cuffs have seams and rigid walls (50 µm) that fold into longitudinal channels in the trachea, allowing silent aspiration of bacteria and causing ventilator-associated pneumonia (VAP).
These micro-thin walls drape softly into tracheal mucosal folds at ultra-low pressures (<20 cmH2O), preventing micro-aspiration without cutting off tracheal blood flow.
Precision Fineblanking for Heavy-Gauge Surgical Instruments
High-precision fineblanking of thick metal plate (2 mm to 10 mm) for surgical stapler linkages, endoscopic articulating gears, orthopedic bone punches, and laparoscopic scissor handles. Employs triple-action hydraulic presses with V-ring impingement to deliver 100% clean, die-cut sheared edges with zero die roll and zero fracture tear, eliminating costly secondary milling.
Governing Consensus Standards
ISO 13485 — Tool qualification and critical stamping process controls ASTM F899 — Martensitic (410, 420, 440A) and precipitation hardening (17-4PH) steels ISO 2768-m — Standard engineering tolerances
Typical Deliverables
Fineblanked components with 100% clean-shear edge qualification inspection reports
Optical CMM dimensional verification data against engineering drawing tolerances (±0.0005″)
Flatness and parallelism inspection certificates (<0.001″ across part surface)
Heat-treated, passivated, and cleanroom-packed surgical instrument blanks
⇌
Off-the-shelf component cross-over:
Need thin-gauge stamped electrical contacts or spring clips rather than heavy-gauge links?
✓Site says it serves medical devices— found“how a full-service medical device contract manufacturing” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “fineblank…” or “fine blank…” or “fine-blank…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“System is certified to ISO 13485:2016 and compliant” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Cadence Inc.: FEI 3009266751; Contract Manufacturer; Staunton, VA · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH, CH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT, IL.
what was checked ↗
· checked 2026-10-20
About Precision Fineblanking for Heavy-Gauge Surgical Instruments (Engineering Primer & Selection Guide)Expand ↓
Standard sheet metal stamping tears metal, leaving 70% of the cut edge rough and fractured; fineblanking shears 100% of the edge smoothly, creating precision bearing surfaces directly from the die.
Triple-Action V-Ring Compression
Fineblanking presses clamp a V-ring into the sheet metal perimeter, putting the blank under massive hydrostatic compression while punch and counter-punch advance simultaneously.
This completely prevents tensile tearing, delivering mirror-smooth vertical edges that require no secondary grinding before surgical instrument assembly.
Autoclave & Compression Molding of Radiolucent Carbon Fiber
✓Site says it serves medical devices— found“production lines for high volume medical devices.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “carbon fib…” or “composite…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485 certified medical design centers design and” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Sanmina: FEI 1000161215; Export-Only Manufacturer, Contract Manufacturer; San Jose, CA · FDA record ↗ · checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✓FDA establishment registration— foundRegistered as PERFORMANCE PLASTICS LTD.: FEI 3002751960; Contract Manufacturer; Cincinnati, OH · FDA record ↗ · checked 2026-10-20
Option 3InCom Composite Solutions
incom.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but the domain is parked or for sale) incom.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About Autoclave & Compression Molding of Radiolucent Carbon Fiber (Engineering Primer & Selection Guide)Expand ↓
Metal surgical tables and retractor arms cast dense white shadows under intraoperative C-arm fluoroscopy, blinding surgeons during vascular stent placement; carbon fiber is completely transparent to X-rays.
Radiolucency and Aluminum Equivalency
Carbon and epoxy consist of low-atomic-number atoms (C, H, O) that absorb virtually no X-ray photons compared to titanium or steel.
Medical composites are validated to have an aluminum equivalency below 1.5 mm, ensuring crisp, unobstructed patient imaging during complex interventions.
High-precision pulsed Nd:YAG and fiber micro-laser welding of fine medical wires, ribbon, and miniature sensor joints. Joins fine wires down to 0.001″ (25 µm) diameter including dissimilar metal pairings (Nitinol to stainless steel, platinum to copper) for catheter steering pull-wires, distal electrode rings, and temperature sensor thermocouples with zero filler material.
Governing Consensus Standards
AWS D17.1 — Laser weld acceptance criteria and visual inspection ISO 13485 — Laser parameter validation (pulse energy, duration, beam spot) ISO 10555-1 — Joint tensile strength limits
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to pacaero.com, which does not name Litron Laboratories & Services) litron.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
Option 3SYNEO
syneo.comWebsite did not answer as this company on 2026-10-20
📍 West Palm Beach, FL
Catheter pull-wire welding automation, automated laser wire termination systems
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to dynamo.com, which does not name SYNEO) syneo.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL.
what was checked ↗
· checked 2026-10-20
About Micro-Laser Fine Wire Butt & Lap Welding (Engineering Primer & Selection Guide)Expand ↓
Soldering and brazing introduce toxic fluxes and large heat-affected zones that anneal cold-worked wire; pulsed lasers melt a microscopic spot in milliseconds without softening adjacent wire.
Dissimilar Metal Micro-Alloy Management
Welding Nitinol directly to stainless steel forms brittle Ti-Fe intermetallic compounds (TiFe2) that fracture under light bending.
Precision micro-welding employs sub-millisecond beam pulses with nickel or tantalum barrier shims to produce ductile, high-strength joints exceeding parent wire tensile ratings.
Miniature Metal Bellows Hydroforming for Implant Pumps
Key Focus: Hydroformed miniature metal bellows, implantable drug pump reservoirs, hermetic seals
High-precision hydraulic forming (hydroforming) of miniature seamless metal bellows for implantable intrathecal drug infusion pumps, pressure transducers, and hermetic surgical shaft seals. Hydroforms multi-convolution cylindrical capsules from Grade 1 Titanium, 316LVM, and Hastelloy C-276 foils down to 0.0015″ (38 µm) wall thickness, delivering million-cycle stroke fatigue lives.
Governing Consensus Standards
EJMA Standards — Bellows design equations, spring rates, and fatigue cycle calculations ISO 13485 — Tooling qualification and hermetic process controls MIL-STD-883 Method 1014 — Helium mass spectrometer leak testing
Typical Deliverables
Hydroformed bellows assemblies with 100% helium mass spectrometer leak test reports (<1×10^-9 atm·cc/s)
Spring rate (N/mm) and effective pressure area calibration curves
Accelerated stroke cycle fatigue life test verification data (1,000,000+ cycles)
Ultrasonically passivated and cleanroom-packaged bellows capsules
⇌
Off-the-shelf component cross-over:
Need drawn seamless cylindrical tube blanks before convolution hydroforming?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
About Miniature Metal Bellows Hydroforming for Implant Pumps (Engineering Primer & Selection Guide)Expand ↓
Implantable drug delivery pumps must expand and contract smoothly for over ten years inside the body without leaking concentrated neuro-toxic drug into patient tissue.
High-Pressure Fluid Convolution Shaping
Hydroforming places a thin, deep-drawn metal cylinder into split dies before injecting pressurized water into the tube interior, bulging the convolutions outward simultaneously.
This cold forming process works the material uniformly without thinning the crests, delivering seamless hermetic barriers capable of millions of expansion strokes.
Surface immobilization of unfractionated or low-molecular-weight heparin onto intravascular catheters, extracorporeal circuits, vascular grafts, and coronary stents. Covalent end-point attachment keeps the active antithrombin-binding pentasaccharide sequence exposed, continuously inactivating thrombin and preventing surface-induced clot formation without systemic anticoagulation.
Governing Consensus Standards
ISO 10993-4 — Thrombogenicity, hemolysis, platelet, and coagulation assays ASTM F2382 — In vitro contact activation and blood compatibility FDA Guidance 2016 — Coating durability, heparin leaching, and surface integrity under cyclic pulse fatigue
Typical Deliverables
Validated end-point covalent heparin graft application process specification
In vitro antithrombin III (ATIII) binding activity assay reports (IU/cm²)
30-day simulated blood flow elution and heparin durability profile
Platelet activation, hemolysis, and thrombin-antithrombin (TAT) complex reduction data
⇌
Off-the-shelf component cross-over:
Need oxygenator fibers, blood pumps, or cannula tubing?
✓Site states ISO 13485 certification— found“is a medical coating company, certified to ISO13485.” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: AZ, SE.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“the variety of medical device coating services” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “heparin” or “thromboresist…” or “hemocompatib…” or “haemocompatib…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO13485 Certified | ISO17025 Accredited” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About Covalently Bound Heparin & Non-Thrombogenic Surface Coatings (Engineering Primer & Selection Guide)Expand ↓
When foreign synthetic materials enter the bloodstream, plasma proteins immediately adsorb onto the surface, triggering platelet adhesion, activation, and acute thrombus formation that can occlude the vessel or embolize downstream.
End-Point Attachment Bio-Mimicry
Traditional bulk-mixed or dip-coated heparin leaches rapidly into circulating blood, losing effectiveness within hours. Modern covalently bonded heparin uses end-point attachment, tethering the polysaccharide chain exclusively at a single terminal carbon atom.
This leaves the internal pentasaccharide sequence freely mobile to bind circulating Antithrombin III (ATIII). The resulting complex accelerates the inhibition of factor Xa and thrombin by up to 1,000-fold, mimicking healthy vascular endothelial glycocalyx for months without systemic bleeding risks.
Plasma-assisted chemical vapor deposition (PACVD) or physical vapor deposition (PVD) of amorphous diamond-like carbon films. Produces an extremely hard (2000–3500 HV), ultra-low friction (µ < 0.1), and chemically inert surface on surgical saw blades, minimally invasive trocars, and orthopedic articulation components.
Governing Consensus Standards
ISO 10993-5 — Cell viability and carbon film toxicity ASTM F2847 — Cleanliness and chemical residue testing of coated implants VDI 3198 — Rockwell C indentation adhesion evaluation (HF1–HF4)
✓Site states ISO 13485 certification— found“Our ISO 13485-certified facilities are strategically located to” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI, CH.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“products and are specifically certified for ISO 13485.” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, LI.
what was checked ↗
· checked 2026-10-20
Option 3IBC Coating Technologies
ibccoating.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) ibccoating.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
About Biocompatible Diamond-Like Carbon (DLC) Coating (Engineering Primer & Selection Guide)Expand ↓
Surgical cutting blades dull rapidly after bone contact, and sliding metal components generate microscopic metallic wear particles that trigger aseptic loosening in joint replacements.
Sp³ Diamond Hybridization
DLC coatings blend sp² (graphitic) and sp³ (diamond) carbon bonds in an amorphous matrix. Ionized plasma creates a dense, atom-level network with hardness approaching natural diamond.
Because carbon is biologically benign, the body does not mount a foreign body giant-cell reaction. DLC dramatically reduces surgical cutting force, prevents tissue sticking during electrocautery, and extends blade sharpness over repeat incisions.
Atomic Layer Deposition (ALD) for Ultra-Thin Hermetic Moisture Barriers
Pulsed gas-phase atomic layer deposition of ultra-thin, pinhole-free metal oxide nanolaminates (e.g., Al2O3, TiO2, HfO2). Coats complex 3D microstructures, flexible neuro-cuff electrodes, and bio-MEMS sensors with sub-nanometer thickness control, delivering Water Vapor Transmission Rates (WVTR) below 10⁻⁵ g/m²/day for long-term implant lifetime.
Governing Consensus Standards
ISO 10993-12 — Thin-film barrier material extraction ASTM F1249 — WVTR testing through barrier films IEEE 11073 — Bio-MEMS electronic longevity and encapsulation reliability
Typical Deliverables
Spectroscopic ellipsometry film thickness and refractive index verification (±0.1 nm)
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 6 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, FR.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CO, FI.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 2 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 2 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CO.
what was checked ↗
· checked 2026-10-20
About Atomic Layer Deposition (ALD) for Ultra-Thin Hermetic Moisture Barriers (Engineering Primer & Selection Guide)Expand ↓
Active implantable neurostimulators, retinal prostheses, and micro-sensors are vulnerable to saline ingress. Electrolyte moisture penetrates microscopic pinholes in conventional silicone or epoxy potting, causing catastrophic short circuits within weeks.
Self-Terminating Surface Reactions
Atomic Layer Deposition uses sequential, self-terminating chemical vapor pulses. Precursor A saturates the substrate surface, excess is purged with inert gas, Precursor B reacts to form an exact monolayer, and the cycle repeats.
Because the reaction is self-limiting, the coating grows with 100% step coverage into high-aspect ratio micro-cavities. Alternating Al2O3 and TiO2 nanolayers prevents crystallite boundary defects, blocking moisture migration at the atomic level.
Medical Grade Selective Gold & Platinum Electroplating
Key Focus: Selective brush/rack plating, Type III Grade A gold, radiopaque bands, corrosion resistance
Precision electrodeposition and electroforming of pure 24-karat gold (ASTM B488 Type III) and platinum onto catheter tips, pacing leads, endoscopic contacts, and Nitinol components. Utilizes micro-masking and automated selective brush plating to deposit radiopaque marker bands and low-resistance electrical contacts exactly where needed without wasting precious metals.
Governing Consensus Standards
ASTM B488 — Purity, hardness, and thickness classifications for gold plating ASTM B685 — Adhesion, porosity, and thickness criteria for medical platinum ISO 10993-15 — Electroplating corrosion leaching
✓Site states ISO 13485 certification— found“ISO 13485:2016 certified precision electroplating for medical devices” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NY.
what was checked ↗
· checked 2026-10-20
Option 3Advanced Surface Technologies (AST)
astcoatings.comWebsite did not answer as this company on 2026-10-20
📍 Arvada, CO
Precision medical plating, rack and barrel gold/nickel, surgical stainless instruments
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but no page read names Advanced Surface Technologies (AST) (domain may have changed hands)) astcoatings.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CO.
what was checked ↗
· checked 2026-10-20
About Medical Grade Selective Gold & Platinum Electroplating (Engineering Primer & Selection Guide)Expand ↓
Cardiovascular surgeons rely on fluoroscopy (real-time X-ray) to navigate catheters into cerebral and coronary arteries. Thin polymer catheters are completely invisible under X-ray without radiopaque metal markers.
High Atomic Density and In Situ Electroforming
Gold (atomic number 79) and platinum (atomic number 78) possess exceptional electron density, attenuating X-rays sharply to show high-contrast catheter silhouettes under minimal radiation dose.
Traditional marker bands are swaged or glued into place, adding rigid stiff points and outer profile bulk. Selective micro-electroplating applies metallic gold directly to braided shafts down to sub-micron thicknesses, preserving catheter flexibility and preventing snagging in tortuous vascular anatomy.
Micro-Arc Oxidation (MAO) / Plasma Electrolytic Oxidation for Titanium Implants
High-voltage electrochemical plasma discharge process converting the native oxide layer of titanium, zirconium, or magnesium implants into a thick, porous ceramic coating. Incorporates calcium, phosphate, and zinc ions into the growing titania matrix during micro-discharge events, drastically enhancing osteoblast adhesion, early bone remodeling, and antimicrobial properties.
Governing Consensus Standards
ISO 13779-2 — Adhesion and chemical composition of ceramic bioactive coatings ASTM F1147 — Tensile bond adhesion to metallic substrates ASTM F1854 — Pore volume fraction and thickness quantification
Typical Deliverables
SEM imaging and stereological pore size distribution report (1–5 µm open micropores)
ASTM F1147 tensile bond strength certificate exceeding 35 MPa
Energy Dispersive X-ray (EDX) elemental mapping of Ca, P, and Zn bio-dopants
In vitro simulated body fluid (SBF) apatite precipitation kinetic study
⇌
Off-the-shelf component cross-over:
Need titanium bone plates, orthopedic screws, or spinal spacers?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 6 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN, GB.
what was checked ↗
· checked 2026-10-20
Option 2IBC Coating Technologies
ibccoating.comWebsite did not answer as this company on 2026-10-20
📍 Lebanon, IN
PEO ceramic coatings on light alloys, titanium wear and osseointegration enhancements
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) ibccoating.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
Option 3Plasma Technology Incorporated (PTI)
plasmatech.comWebsite did not answer as this company on 2026-10-20
📍 Torrance, CA / South Windsor, CT
Medical thermal spray and plasma coatings, hydroxyapatite and porous titanium
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but the domain is parked or for sale) plasmatech.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain parked or for sale). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, CT.
what was checked ↗
· checked 2026-10-20
About Micro-Arc Oxidation (MAO) / Plasma Electrolytic Oxidation for Titanium Implants (Engineering Primer & Selection Guide)Expand ↓
Smooth machined titanium bone screws and spinal cages experience fibrous encapsulation rather than direct bone bonding, resulting in micromotion, implant loosening, and surgical revision.
High-Energy Micro-Plasma Sintering
Micro-Arc Oxidation applies high pulsed voltages (300V–500V) in an aqueous electrolyte bath, exceeding dielectric breakdown of the natural surface oxide. Microscopic electrical sparks dance across the part, heating the surface locally to thousands of degrees Celsius.
This flash-sinters the titanium into hard crystalline anatase and rutile phases while incorporating dissolved electrolyte minerals like calcium and phosphate directly into the ceramic crystal lattice. The resulting microporous, sponge-like surface guides bone cells deep into the coating, achieving robust secondary biological fixation.
Laser Surface Texturing (LST) for Superhydrophobic / Anti-Wetting Surfaces
Chemical-free surface functionalization using ultrashort pulse (USP) femtosecond and picosecond lasers to etch sub-micron hierarchical pillars, grooves, and dimples directly into metallic or polymeric medical devices. Replicates biomimetic lotus-leaf microstructures to achieve superhydrophobic water contact angles (>150°), or directional micro-grooves that guide cell alignment and prevent bacterial biofilm adhesion.
Governing Consensus Standards
ISO 10993-1 — General biocompatibility of modified surfaces ASTM D7334 — Goniometric water droplet contact angle measurement ISO 22196 — Biofilm reduction testing on laser textured surfaces
Typical Deliverables
Goniometer water droplet contact angle test certificates (>150° superhydrophobic or <10° superhydrophilic)
3D laser confocal surface topography profilometry (Ra, Rz, Sdr surface area ratio)
Field Emission SEM micrographs of nanoscale Laser-Induced Periodic Surface Structures (LIPSS)
In vitro bacterial adherence inhibition assay report (Staphylococcus aureus and E. coli)
⇌
Off-the-shelf component cross-over:
Need surgical camera housings, optical windows, or trocars?
✓Site says it serves medical devices— found“Medical Devices and Sheet Metal Processing” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “laser” and (“textur…” or “surface structur…” or “surface treat…”). Found: laser.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“to DIN EN ISO 13485 (replacing certification according” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: DE.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NH.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“trimming, thin-film etching, and medical device manufacturing.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “laser” and (“textur…” or “surface structur…” or “surface treat…”). Found: laser.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Laser Surface Texturing (LST) for Superhydrophobic / Anti-Wetting Surfaces (Engineering Primer & Selection Guide)Expand ↓
Traditional chemical anti-fouling coatings rely on silanes or fluoropolymers that can degrade, delaminate, or leach toxic by-products into blood or living tissue over time.
Athermal Femtosecond Direct Structuring
Femtosecond lasers deliver high-intensity optical pulses lasting only quadrillionths of a second. The pulse duration is shorter than the electron-phonon relaxation time, vaporizing material directly via optical breakdown before thermal heat can diffuse into the surrounding metal.
This cold ablation creates sub-micron re-entrant pillared architectures without heat-affected zones (HAZ) or slag. Air pockets remain trapped between liquid droplets and surface micro-pillars, causing blood and saline droplets to roll off instantly while denying bacteria the anchor points needed to establish biofilm colonization.
High-resolution scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM/EDX) for automated foreign particulate isolation and elemental fingerprinting. Rapidly characterizes particulate contaminants on vascular delivery systems, prefilled syringes, and orthopedic implants to identify root causes in injection molding, wear debris, or packaging breakdown.
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MO.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“certification services to medical device manufacturers looking” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “sem” or “edx” or “eds” or “electron microscop…” or “particulate…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
About Automated SEM/EDX Micro-Particulate Identification (Engineering Primer & Selection Guide)Expand ↓
Subvisible particulates injected intravenously or left inside coronary catheters can cause micro-embolisms, stroke, and systemic granulomatous reactions in vulnerable patients.
Spectral Fingerprinting of Contaminants
Light obscuration test methods can count particle sizes, but they are blind to chemical composition. Automated SEM/EDX sweeps an electron beam over membrane filters, automatically identifying every particle exceeding 2 microns and pulsing X-rays to obtain an instant atomic emission spectrum.
By matching elemental signatures against a spectral library, engineers immediately differentiate stainless steel grinding swarf (Fe-Cr-Ni) from glass delamination flakes (Si-O-Na) or fluoropolymer seal abrasion (C-F), pinpointing exact cleanroom process failures.
Advanced multi-parametric flow cytometry and enzyme-linked immunosorbent assay (ELISA) testing to quantify blood cellular and immunological response to medical devices under ISO 10993-4. Analyzes fluorescently tagged monoclonal antibody binding to detect resting vs. activated platelets (P-selectin CD62P, PAC-1), leukocyte-platelet aggregates, and complement anaphylatoxins (C3a, C5a, SC5b-9).
Governing Consensus Standards
ISO 10993-4 — Hemolysis, thrombosis, coagulation, and immunology ASTM F2888 — Flow cytometric platelet activation markers FDA Guidance 2020 — Blood-contacting safety and complement cascade activation requirements
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
About Flow Cytometry & Complement Activation Hemocompatibility (Engineering Primer & Selection Guide)Expand ↓
Cardiovascular implants and hemodialysis circuits can trigger silent immune cascades or microvascular thromboses that clinical bench clotting times fail to catch.
Single-Cell Fluorescent Tagging
Flow cytometry interrogates tens of thousands of individual blood cells per second as they pass through focused laser beams. Fluorescent antibodies specific to CD62P (P-selectin) bind exclusively to alpha granules exteriorized during platelet activation.
Simultaneously, ELISA kits measure SC5b-9 (the membrane attack complex) in plasma. This dual cellular and molecular approach provides regulators with absolute proof that the blood-contacting device does not provoke insidious complement-mediated inflammation or sub-clinical clotting.
ASTM F2096 Gross Leak Testing by Internal Pressurization (Bubble Emission)
Standardized gross leak detection for medical device sterile barrier packaging (pouches, header bags, and thermoformed blister trays) by internal pressurization under water. Submerges the package into a clear testing tank, introduces controlled air pressure via an internal injection needle, and visually monitors for a continuous stream of escaping bubbles indicating channel leaks or puncture defects down to 250 µm.
Governing Consensus Standards
ASTM F2096 — Test apparatus, pressure calibration, and bubble observation criteria ISO 11607-1 — Integrity testing for sterile barrier systems ASTM F1980 — Post-aging seal integrity verification
Typical Deliverables
Packaging gross leak pass/fail test report certified to ASTM F2096
Test pressure limit verification record preventing package burst during submersion
High-resolution photographic documentation of detected leak locations and pore defects
Full packaging validation summary report for regulatory sterile barrier files
⇌
Off-the-shelf component cross-over:
Need Tyvek lids, blister trays, or sterilization pouches?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
About ASTM F2096 Gross Leak Testing by Internal Pressurization (Bubble Emission) (Engineering Primer & Selection Guide)Expand ↓
A single microscopic breach or unsealed channel in a sterile barrier pouch allows bacteria and spores to enter during shipping and hospital handling, rendering the sterile implant deadly.
Controlled Water-Submersion Pressurization
ASTM F2096 provides an indispensable whole-package integrity screening tool. A hollow puncture needle pierces the package center and injects regulated compressed air until the package walls tense without rupturing the heat seals.
When submerged under 1 inch of water, air escapes through any pinhole or seal channel defect, creating an unmistakable stream of rising bubbles. It confirms package integrity across the entire perimeter, sealing geometry, and Tyvek surface in under 30 seconds.
Fine & Gross Leak Testing by Helium Mass Spectrometry (MIL-STD-883)
Key Focus: Helium mass spectrometry leak testing, MIL-STD-883 Method 1014, hermetic seal rate < 1x10-9 atm*cc/s
Ultra-sensitive quantitative leak testing of hermetically sealed titanium packages, feedthrough headers, and implantable electronic enclosures using tracer helium gas and a calibrated mass spectrometer. Implements helium bombing (pressurization chamber) and vacuum chamber sniffer methods under MIL-STD-883 Method 1014 to detect fine leak rates as tiny as 1 × 10⁻¹¹ atm·cc/sec, guaranteeing zero body fluid ingress over 10+ year implant lifetimes.
Governing Consensus Standards
MIL-STD-883 Method 1014 — Fine leak by helium mass spectrometry and gross bubble leak ISO 20485 — Calibration and measurement protocol for mass spectrometers ASTM E499 — Sniffer probe leak measurement
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
Option 2EBTEC Corporation
ebtec.comWebsite did not answer as this company on 2026-10-20
📍 Agawam, MA
Electron beam welding, laser welding, hermeticity helium leak testing for medical cans
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers) ebtec.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
Option 3Litron Laboratories
litron.comWebsite did not answer as this company on 2026-10-20
📍 Agawam, MA
Hermetic seal testing, helium bombing, laser sealing, metallurgical weld evaluation
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to pacaero.com, which does not name Litron Laboratories & Services) litron.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
About Fine & Gross Leak Testing by Helium Mass Spectrometry (MIL-STD-883) (Engineering Primer & Selection Guide)Expand ↓
Active medical implants operate bathed in warm, conductive, salty body fluids. Even a microscopic seal crack that admits a few nanoliters of moisture over several years will corrode microchips and deplete batteries.
Tracer Gas Bombing and Molecular Separation
Helium is an ideal tracer: its tiny monatomic size (0.26 nm diameter) slips through the smallest micro-fissures, and its background concentration in ambient air is only 5 ppm. In the bombing method, welded titanium implant cans are placed in a high-pressure helium chamber, forcing gas through any leak paths.
The parts are then transferred to a vacuum chamber connected to a magnetic sector mass spectrometer. Any escaping helium is ionized, magnetically deflected by mass-to-charge ratio (m/z = 4), and converted into an electric current that measures leak rates down to 10⁻¹¹ atm·cc/sec.
ASTM D4169 / ISTA 3A Random Vibration & Drop Shock Transit Simulation
Key Focus: ASTM D4169, ISTA 3A distribution simulation, random vibration, drop shock, altitude testing
Rigorous dynamic environmental testing evaluating medical device packaging and delicate equipment survival during global shipping and handling. Exposes packaged products to sequential hazards under ASTM D4169 (Assurance Level I/II) and ISTA 3A, including multi-axis random vibration profiles, rotational and free-fall drops, compressive stacking, and vacuum altitude simulation.
Governing Consensus Standards
ASTM D4169 — Distribution cycle simulation profiles DC-13 and DC-1 ISTA 3A — Top-load compression, random vibration with top load, and shock drops ISO 11607-1 — Package performance under dynamic transit stress
Typical Deliverables
ISTA / ASTM D4169 accredited distribution simulation test certificate
Accelerometer vibration profile spectra (PSD g²/Hz) and peak G shock recordings
Detailed visual inspection and physical dimensional damage assessment
Post-transit sterile barrier integrity re-verification test reports
⇌
Off-the-shelf component cross-over:
Need custom foam dunnage, corrugated cartons, or shipping pallets?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
About ASTM D4169 / ISTA 3A Random Vibration & Drop Shock Transit Simulation (Engineering Primer & Selection Guide)Expand ↓
A medical device can be perfectly engineered in the cleanroom, but if rough trucking roads or cargo plane turbulence break a fragile weld or tear an outer Tyvek pouch, the product arrives in the operating room unsterile and unusable.
Realistic Multi-Hazard Sequencing
ASTM D4169 subjects test shippers to a realistic gauntlet of transit hazards in logical sequence. First, packages undergo atmospheric pre-conditioning, followed by compression simulating warehouse stacking.
Next, electrodynamic shakers subject the cargo to broadband random vibration matching real truck beds and cargo aircraft power spectral density curves. Finally, packages endure rotational and corner free-fall drops from calibrated heights before undergo post-test sterile seal inspection.
Mechanical performance testing measuring the rotational response, torque transmission ratio, and twist-to-failure limits of interventional vascular guidewires, steerable sheaths, and catheter shafts. Tests devices in calibrated ASTM and tortuous anatomical silicone vascular models (e.g., carotid or coronary siphon), measuring proximal vs. distal rotational lag and maximum revolutions before kink or wire fracture under ISO 10555 and ASTM F1537.
Governing Consensus Standards
ISO 10555-1 — Burst pressure, tensile properties, and catheter flexibility ASTM F1537 — Material fatigue limits for interventional metallic shafts FDA Guidance 2019 — Torque transmission, rotational fatigue, and tip flexibility
Typical Deliverables
Dynamic torque vs. angular rotation curves (1:1 tracking ratio quantification)
Torque-to-failure limit test report showing maximum degrees to rupture/kink
Rotational fatigue endurance curves under continuous multi-turn cycling
SEM imaging of braid or core wire fracture surfaces identifying failure modes
⇌
Off-the-shelf component cross-over:
Need hypotubes, braided catheter shafts, or steerable pull-rings?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
Option 3Medical Device Testing Services (MDTS)
mdt-world.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) mdt-world.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
About Guidewire & Catheter Torqueability / Rotational Fatigue (ASTM F1537) (Engineering Primer & Selection Guide)Expand ↓
In acute ischemic stroke interventions, a neuro-interventionalist must rotate the guidewire handle outside the patient and expect the distal tip to turn in exact 1:1 synchronization inside the tortuous brain vessels.
Whip and Lag Dynamics in Tortuous Models
When friction accumulates inside a tortuous artery, torque energy gets stored elastically along the guidewire shaft. Instead of turning smoothly, the tip lags behind and then snaps forward violently ("whipping"), which can perforate delicate arterial walls.
Torqueability testing instruments the distal tip with optical rotary encoders inside heated 37°C silicone vascular anatomical models. Continuous torque sensors record torque buildup, hysteresis lag, and catastrophic yield limits under full clockwise and counter-clockwise rotations.
Orthopedic Joint Wear Simulation & Particulate Debris Analysis (ISO 14242/14243)
Key Focus: ISO 14242 hip simulator, ISO 14243 knee simulator, gravimetric wear rate, UHMWPE wear debris
Physiological multi-axis joint wear simulation subjecting total hip, knee, and spinal disc replacements to 5 to 10 million cycles of gait kinematics in temperature-controlled bovine serum. Measures micro-gram gravimetric weight loss and isolates sub-micron polyethylene (UHMWPE) and metal wear debris for SEM particle characterization under ISO 14242 and ISO 14243 standards.
Governing Consensus Standards
ISO 14242-1 — Hip simulator gait kinematic cycles ISO 14243-1 — Knee wear simulator kinematic profiles ASTM F1877 — Morphology, size, and aspect ratio of isolated wear particles
Typical Deliverables
Gravimetric wear rate report (mg/million cycles) across 5 to 10 million test cycles
Serum protein degradation monitoring and replenishment logs
SEM imaging and image-analysis particle size distribution of isolated UHMWPE/metal debris
3D optical profilometry surface roughness (Ra) wear scar topography maps
⇌
Off-the-shelf component cross-over:
Need femoral heads, tibial trays, or acetabular liners?
✓Site says it serves medical devices— found“help you build medical devices and bring” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “wear test…” or “wear simulat…” or “joint simulat…” or “tribolog…”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485 Certified: Medical Devices Quality Management” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as ORCHID ORTHOPEDIC SOLUTIONS LANSING: FEI 3005852519; Contract Manufacturer; Holt, MI · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NY, GB.
what was checked ↗
· checked 2026-10-20
About Orthopedic Joint Wear Simulation & Particulate Debris Analysis (ISO 14242/14243) (Engineering Primer & Selection Guide)Expand ↓
Artificial joint replacements are expected to survive 20 to 30 years inside active patients. Sub-micron plastic wear particles generated by articular friction trigger macrophage phagocytosis and chronic osteolysis, leading to implant loosening.
The articulation occurs in 25% bovine calf serum maintained at body temperature (37°C) with sodium azide antimicrobial agents. Periodic micro-balance weighing and acid digestion isolate microscopic UHMWPE debris, proving to regulators that the implant design minimizes osteolytic particle release.
White-Light Interferometry & 3D Optical Topography
Non-contact 3D surface metrology utilizing coherence scanning white-light interferometry (WLI) and confocal optical microscopy. Measures surface roughness (Sa, Sq, Sz), step heights, and microscopic defect topographies down to 0.1 nanometer vertical resolution without contacting or scratching delicate optical surfaces, catheter coatings, or polished orthopedic bearings under ISO 25178.
Governing Consensus Standards
ISO 25178-2 — Areal 3D surface texture parameters ISO 4287 — 2D linear profile roughness parameters (Ra, Rz) ASTM E2864 — Surface topography of nano-scale implant finishes
Typical Deliverables
High-resolution 3D false-color topographic elevation surface maps
ISO 25178 areal roughness parameter table (Sa, Sq, Ssk, Sku, Sz) with sub-nm accuracy
High-precision step-height and trench depth measurement profiles
Volumetric wear scar and void volume calculations for durability assessments
⇌
Off-the-shelf component cross-over:
Need surgical optics, endoscope lenses, or sapphire windows?
✓Site says it serves medical devices— found“Medical Device Companies” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “interferomet…” or “profilomet…” or “surface metrolog…” or “topograph…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, NY.
what was checked ↗
· checked 2026-10-20
Option 2Carl Zeiss Metrology Services
zeiss.comWebsite did not answer as this company on 2026-10-20
📍 Maple Grove, MN / Oberkochen, Germany
White-light interferometry, confocal optical profilometry, CT metrology for medical devices
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (HTTP 200, but no page read names Carl Zeiss Metrology Services (domain may have changed hands)) zeiss.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, DE.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT.
what was checked ↗
· checked 2026-10-20
About White-Light Interferometry & 3D Optical Topography (Engineering Primer & Selection Guide)Expand ↓
Traditional stylus profilometers drag a diamond needle across the part, which can gouge soft bio-coatings and miss tiny micro-pits located between adjacent measurement scan lines.
Light Wave Interference Nanometry
White-light interferometry splits a broadband light beam into two paths: one reflects from an internal reference mirror, and the other reflects from the sample surface. When the two beams recombine, constructive and destructive light interference creates microscopic fringe patterns.
By scanning the objective lens vertically in sub-nanometer increments, software tracks the peak fringe contrast across millions of image pixels simultaneously, producing an exact 3D topographic height map with vertical resolution under 0.1 nanometers.
Key Focus: OTA RF wireless testing, anechoic chamber, Total Radiated Power (TRP), Total Isotropic Sensitivity (TIS)
Over-The-Air (OTA) RF antenna characterization and wireless connectivity qualification in fully anechoic test chambers. Measures Total Radiated Power (TRP), Total Isotropic Sensitivity (TIS), and 3D spherical radiation patterns for Bluetooth Low Energy (BLE), Wi-Fi, MedRadio (401–406 MHz), and cellular IoT medical devices. Uses FDA-recognized tissue-simulating phantoms to verify wireless range and reliability inside the human body.
Governing Consensus Standards
CTIA OTA Test Plan — TRP and TIS spherical testing protocols ANSI/RESNA WC-2 — Assistive wireless device RF compliance FDA Wireless Guidance 2013 — RF QoS, coexistence, antenna performance, and security
Typical Deliverables
3D spherical antenna radiation pattern heatmaps (gain, directivity, polarization)
Total Radiated Power (TRP) and Total Isotropic Sensitivity (TIS) pass/fail tables
Human body phantom tissue-absorption detuning and link budget calculations
Regulatory compliance report ready for FCC, ISED, and CE wireless medical filings
⇌
Off-the-shelf component cross-over:
Need RF telemetry antennas, shielded enclosures, or baluns?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “certification services (including ISO 13485 and MDSAP) and”, not counted (qualified: "certification services").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “device manufacturers include ISO 13485 and ISO 9001”, not counted (qualified: "registration and certification for").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, IL.
what was checked ↗
· checked 2026-10-20
About Over-The-Air (OTA) RF Antenna Radiation Performance & TRP/TIS (Engineering Primer & Selection Guide)Expand ↓
When a patient places an insulin pump or continuous glucose monitor against their skin, the water and electrolytes in human tissue absorb radio waves and detune the antenna, dropping wireless range from 30 feet down to 2 feet.
Spherical Anechoic Power and Sensitivity Mapping
Conducted RF testing using coaxial cable connections ignores real-world radiation physics. OTA testing mounts the medical device on a robotic gimbal inside an RF anechoic chamber lined with carbon-loaded foam pyramids that eliminate reflections.
The chamber sweeps the entire 360-degree sphere while mounted against tissue-equivalent human body phantoms. It computes Total Radiated Power (TRP) and Total Isotropic Sensitivity (TIS), proving to FDA reviewers that the device maintains reliable communication even in crowded wireless environments.
ASTM B117 & ASTM G85 Cyclic Salt Spray / Fog Corrosion Testing
Accelerated environmental corrosion testing exposing surgical stainless steels, titanium fasteners, coated aluminum enclosures, and electrical connectors to atomized neutral or acidified sodium chloride fog. Runs continuous 24-hour to 1,000-hour exposure cycles under ASTM B117 and ASTM G85, validating passivation integrity, galvanic couple resistance, and anti-pitting durability before clinical release.
Governing Consensus Standards
ASTM B117 — Operating conditions for continuous 5% NaCl salt spray chamber ASTM G85 — Cyclic acidified and electrolyte fog exposures ISO 9227 — NSS, AASS, and CASS international corrosion tests
Typical Deliverables
Continuous exposure test log documenting daily chamber temperature, pH, and fallout rate
Periodic high-resolution macro-photographs showing pitting and oxidation onset
Corrosion creep and blister evaluation ratings per ASTM D1654
Metallurgical cross-section microscopy verifying absence of intergranular cracking
⇌
Off-the-shelf component cross-over:
Need passivated stainless screws, surgical handles, or hinges?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 13485 - Medical devices Quality management systems”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN, OH.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: KY, NY.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedtimeout after 12 s. Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (timeout after 12 s). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA, MN.
what was checked ↗
· checked 2026-10-20
About ASTM B117 & ASTM G85 Cyclic Salt Spray / Fog Corrosion Testing (Engineering Primer & Selection Guide)Expand ↓
Reusable surgical instruments face aggressive hospital reprocessing environments: enzymatic detergents, hot deionized rinses, steam autoclaves, and disinfectant chemicals. Any residual free iron from machining causes flash rust and pitting.
Atomized Electrolyte Accelerated Stress
ASTM B117 operates a sealed heated chamber at 35°C, atomizing a 5% sodium chloride solution into a dense, moist fog that blankets the test articles continuously. The warm, oxygen-rich saline fog rapidly attacks unpassivated iron inclusions and porous coating defects.
Passing standard 96-hour or 240-hour exposure without reddish rust pitting provides definitive verification that passivation (ASTM A967) and surface finishing processes successfully formed a pure, unbroken chromium-oxide protective layer.
Key Focus: Glove-free isolator filling, robotic liquid dispensing, ISO Class 5 / Grade A, Annex 1 compliance
High-precision automated aseptic filling of combination drug-device products, hyaluronic acid dermal fillers, biologic hydrogels, and ocular suspensions inside closed restricted access barrier systems (RABS) and gloveless isolators. Employs robotic peristaltic and rotary piston pumps in continuous vapor-phase hydrogen peroxide (VHP) environments, eliminating human intervention and achieving zero-sterility-defect processing under EU GMP Annex 1.
Governing Consensus Standards
EU GMP Annex 1 — Barrier technology, automated glove-free isolators, and continuous particulate monitoring ISO 13408-1 — Aseptic validation, media fills, and environmental controls USP <1116> — Air and surface bioburden contamination limits
Typical Deliverables
Media fill validation report (three consecutive runs of 5,000+ units with zero turbidity)
Continuous Grade A viable / non-viable environmental air particle monitoring logs
Fill weight gravimetric distribution report with 100% in-process tare/gross checkweighing
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MI.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, PA.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “aseptic” or “isolator…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, DE.
what was checked ↗
· checked 2026-10-20
About Closed RABS & Glove-Free Isolator Aseptic Liquid Filling (Engineering Primer & Selection Guide)Expand ↓
Human operators represent over 90% of particulate and microbial contamination in cleanrooms. Even fully gowned personnel shed skin flakes, bacteria, and microscopic fibers during manual intervention.
Robotic Automation in Sealed Environments
Gloveless barrier isolators eliminate human physical presence from the aseptic zone. Robotic arms manufactured with smooth, mirror-polished stainless steel housing manipulate vials, fill needles, and stoppers without human gloves.
Integrated vapor-phase hydrogen peroxide (VHP) generators sterilize the internal chamber to a 6-log sterility assurance level. Continuous optical particle counters and active air samplers verify that not a single microbial colony forms across thousands of sterile units.
Precision cleanroom assembly and ultra-high temperature vacuum brazing of ceramic-to-metal electrical feedthroughs. Bonds high-purity alumina (99.8% Al2O3) or ruby insulators to biocompatible titanium housings using gold brazing alloys (Au-Ge or pure Au) and multi-pin platinum-iridium (Pt-Ir 90/10) conductor leads, delivering hermeticity below 1 × 10⁻¹⁰ atm·cc/sec for active implantable medical devices (AIMD).
Governing Consensus Standards
ISO 14708-1 — Feedthrough electrical and hermetic requirements MIL-STD-883 Method 2004 — Bending, lead fatigue, and pin pull adhesion ASTM F603 — Dielectric insulation ceramic criteria
Typical Deliverables
Helium mass spectrometer hermetic seal verification (< 1 × 10⁻¹⁰ atm·cc/sec per pin)
Ceramic insulation resistance test report (> 10¹² Ohms at 500 VDC)
Pin-pull and terminal shear mechanical adhesion test data (> 25 N pull strength)
Micro-section metallographic cross-sections of braze meniscus fillets without voids
⇌
Off-the-shelf component cross-over:
Need titanium cans, platinum leads, or hermetic headers?
✓Site says it serves medical devices— found“contribution: Production of medical technology such as” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “feedthrough…” or “feed-through…” or “brazing” or “brazed” or “braze” or “hermetic…”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as HERAEUS MEDICAL COMPONENTS, LLC: FEI 3008988055; Specification Developer, Complaint File Establishment, Contract Manufacturer; Saint Paul, MN · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“are certified to ISO 9001:2015, ISO 13485:2016, ISO” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, DE.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Ceramic-to-Metal Hermetic Feedthrough Brazing & Gold Pin Assembly (Engineering Primer & Selection Guide)Expand ↓
Active neurostimulators and pacemakers require electrical current to pass through their titanium outer shell to stimulate nerves and heart muscle, while completely blocking the surrounding warm saline body fluids.
High-Temperature Vacuum Wetting and Bonding
Metals and ceramics possess vastly different coefficients of thermal expansion. Attempting to weld them directly causes instantaneous cracking. Feedthrough specialists deposit a nanometer titanium/molybdenum wetting layer onto sapphire or dense alumina ceramic insulators.
In an ultra-high vacuum furnace heated past 1,064°C, pure 24-karat gold braze melts and wicks into the capillary gaps between the titanium flange and platinum pins. The resulting gold alloy joint forms a true metallurgical hermetic seal that remains stable inside the patient for decades.
Cleanroom Ultrasonic Plastic Welding for Diagnostics & Manifolds
Key Focus: Ultrasonic plastic welding, ISO Class 7 cleanroom, energy director/shear joint, hermetic fluidics
High-speed acoustic fusion joining of medical polymer components inside ISO Class 7 cleanrooms without glues, solvents, or foreign fasteners. Uses ultrasonic horns vibrating at 20 kHz to 40 kHz under servoelectric or pneumatic pressure to induce localized intermolecular friction at energy director ridges or shear joints, producing hermetic, pressure-tight welds on microfluidic lab-on-a-chip cartridges and IV drip chambers in fractions of a second.
Governing Consensus Standards
ISO 13485 — Validation of specialized joining processes ASTM D4883 — Acoustic polymer behavior FDA QSR 21 CFR 820.75 — Installation, operational, and performance qualification (IQ/OQ/PQ) of welders
Typical Deliverables
Full IQ/OQ/PQ process validation protocol and statistical burst pressure testing report
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 11 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “bonding methods in FDA or ISO 13485 environments.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, DE.
what was checked ↗
· checked 2026-10-20
About Cleanroom Ultrasonic Plastic Welding for Diagnostics & Manifolds (Engineering Primer & Selection Guide)Expand ↓
Microfluidic in vitro diagnostic (IVD) cartridges contain pre-loaded freeze-dried reagents. Using chemical adhesives to bond the cartridge cover can poison enzymatic reactions or clog sub-millimeter channels with volatile solvent fumes.
Molecular Acoustic Fusion without Adhesives
Ultrasonic welding converts high-frequency electrical energy into mechanical vertical vibrations. A custom titanium horn presses onto the molded plastic part with calibrated force, concentrating vibrational energy into a triangular energy director ridge just 0.4 mm tall.
In less than 200 milliseconds, intermolecular friction melts the ridge, causing the plastic polymers to interdiffuse across the joint line before the machine applies a holding freeze pressure. The resulting joint is pure parent plastic: chemically clean, transparent, and pressure-tight.
In-Line Machine Vision & AI Automated Optical Inspection (AOI)
Key Focus: Telecentric machine vision, AI deep learning surface inspection, 100% in-line dimensional verification
High-throughput inline automated optical inspection (AOI) utilizing high-resolution CMOS cameras, telecentric lenses, multi-spectrum structured lighting, and deep-learning AI algorithms. Inspects 100% of finished medical devices for micron-scale molding burrs, braid wire crossover defects, particulate contamination, adhesive fill fillets, and laser marking readability at line rates exceeding 60 parts per minute.
Governing Consensus Standards
ISO 13485 — In-process inspection and statistical quality verification 21 CFR 820.80 — Automated inspection record integrity and defect sorting GAMP 5 — Computerized machine vision software validation
Typical Deliverables
GAMP 5 machine vision system validation package (IQ/OQ/PQ and software test scripts)
100% part inspection data logs with high-resolution pass/fail image archives
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, NJ.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 429). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 429)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 429)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 429)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, WI.
what was checked ↗
· checked 2026-10-20
Option 3Invotec Solutions (IMA Group)
invotec.comWebsite did not answer as this company on 2026-10-20
📍 Dayton, OH
Custom medical automation, inline AOI inspection cells, catheter inspection stations
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to hahnautomation.group, which does not name Invotec Solutions (IMA Group)) invotec.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
About In-Line Machine Vision & AI Automated Optical Inspection (AOI) (Engineering Primer & Selection Guide)Expand ↓
Human cleanroom inspectors experience optical fatigue after 20 minutes, leading to escape rates as high as 15% for subtle defects like micro-cracks, foreign fibers, or incomplete glue dispensed inside clear plastic parts.
Telecentric Optics and Neural Edge Detection
Automated Optical Inspection replaces subjective manual scrutiny with mathematical certainty. Telecentric lenses maintain identical optical magnification even if the part vibrates or shifts slightly along the optical axis, eliminating perspective distortion.
Synchronized multi-angle dome and co-axial strobe lights illuminate the component, highlighting surface micro-scratches and fluid meniscus fillets. Deep-learning neural networks trained on thousands of golden and defective samples classify complex anomalies in milliseconds, automatically rejecting non-conforming parts into a locked bin.
High-precision cleanroom assembly and device packaging integrating prefilled glass or COP syringes into spring-loaded autoinjector pens, safety needle shields, and wearable bolus injectors. Operates automated pick-and-place indexing lines with controlled plunger insertion, optical orientation verification, needle cover snap-fit torque monitoring, and 100% laser tamper-evident labeling.
Governing Consensus Standards
ISO 11608-1 — Dose accuracy, drop test, and activation force ISO 11040-4 — Barrel dimensions and mechanical resistance FDA Guidance 2013 — Design controls and combination product safety
Typical Deliverables
Automated batch assembly history records (DHR) with 100% torque and force monitoring curves
Activation force, needle extension depth, and injection delivery time verification reports
Automated optical vision inspection data verifying cap alignment and syringe label integrity
Final secondary packaging, carton blister packing, and serialized UDI aggregation logs
⇌
Off-the-shelf component cross-over:
Need syringe barrels, needle cannulas, or rubber plungers?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “11, ISO 9001, ISO 13485, MDD 93/42/EEC, AMG/MPG/AMWHV.”, not counted (no certification wording bound to the mention).
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as Gerresheimer Peachtree City, L.P.: FEI 3013445959; Contract Manufacturer; Peachtree City, GA · FDA record ↗ · checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“Medical Assembly & Services LLC ISO 13485 certificate” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CH, TW.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “It complies with ISO 13485:2016, EU Medical Device”, not counted (qualified: "complies").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CH.
what was checked ↗
· checked 2026-10-20
About Prefilled Syringe Auto-Injector & Safety Syringe Assembly (Engineering Primer & Selection Guide)Expand ↓
High-viscosity biologic drugs (like monoclonal antibodies) require high-force internal drive springs. If an autoinjector assembly line applies uneven insertion pressure, the fragile glass syringe barrel can shatter violently.
Controlled Spring Compression and Snap-Fit Verification
Autoinjector assembly machinery compresses high-load coiled springs while simultaneously guiding the prefilled syringe into place with multi-axis load cells that monitor insertion force every millisecond.
Laser displacement sensors confirm the exact needle shield locking depth, while high-speed optical cameras verify that the drug liquid remains free of air bubbles or glass chips. The finished autoinjector delivers effortless, single-button subcutaneous drug administration for chronic arthritis and diabetes patients.
Automated thermal blade welding and radio-frequency sealing of thermoplastic elastomer (TPE) tubing (e.g., C-Flex, PharMed BPT) to create sterile, closed fluid pathways in biopharmaceutical processing and cell therapy manufacturing without exposing fluid paths to ambient cleanroom air. Melts and fuses tube ends using a depyrogenating single-use heated blade at 260°C.
Governing Consensus Standards
ISO 13408-1 — Closed system integrity and sterile connections ASTM F838 — Fluid pathway microbial barrier efficacy ASME BPE — Single-use assemblies and tube connection integrity
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 9 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: DE.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MD.
what was checked ↗
· checked 2026-10-20
About Single-Use Sterile Tube Welding & Aseptic Disconnect (Engineering Primer & Selection Guide)Expand ↓
Connecting sterile bags of cell culture media or autologous CAR-T patient cells in an open environment invites devastating bacterial or mycoplasma contamination, ruining life-saving therapies.
High-Heat Thermal Knife Sterilization
Sterile tube welders place two thermoplastic elastomer tube segments into opposing clamping jaws. A single-use stainless steel razor blade heats rapidly to 260°C, depyrogenating the blade surface in seconds.
The red-hot blade slices smoothly through both clamped tubes, sealing their molten ends against the blade surface. The machine shifts the jaws to align the two tubes, withdraws the blade, and presses the molten ends together. The polymers fuse seamlessly into a continuous, hermetic, sterile fluid conduit without introducing airborne particles.
High-precision thermal forming of distal catheter tips, introducer dilator tapers, and flare terminations using high-frequency radiofrequency (RF) induction heating. Clamps extruded thermoplastic shafts (e.g., Pebax, polyurethane, PTFE liners) over internal mandrels into precision-ground carbide or brass dies, shaping uniform, burr-free, atraumatic rounded radiuses and tapered transitions in seconds.
Governing Consensus Standards
ISO 10555-1 — Catheter tip curvature, transition smoothness, and pull strength ASTM F623 — Tip retention and shaft dimensional tolerances FDA Guidance 2018 — Tip taper geometry, insertion force, and dilation transitions
Typical Deliverables
High-magnification optical comparator tip contour and radius verification report (±0.025 mm)
Tensile bond strength test data between formed soft tip and braided shaft (>15 N)
Surface finish profilometry proving smooth, flash-free transition at the die parting line
Statistical process capability (Cpk > 1.33) documentation for distal outer diameter
⇌
Off-the-shelf component cross-over:
Need extruded Pebax tubing, braid shafts, or fluoropolymer liners?
✓Site states ISO 13485 certification— found“control and certifications include ISO 13485:2016, defining the” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
Option 2SYNEO
syneo.comWebsite did not answer as this company on 2026-10-20
📍 West Palm Beach, FL / Galway, Ireland
Automated RF catheter tipping machines, hole punchers, precision tipping dies and contract tipping
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (redirects to dynamo.com, which does not name SYNEO) syneo.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno page read names the company, so its statements are not this company’s. Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: FL.
what was checked ↗
· checked 2026-10-20
Option 3Vante / PlasticWeld Systems
vante.comWebsite did not answer as this company on 2026-10-20
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers and redirects to cathetertipping.com) vante.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers and redirects to cathetertipping.com). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers and redirects to cathetertipping.com). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (TLS error (ERR_TLS_CERT_ALTNAME_INVALID); plain http:// answers and redirects to cathetertipping.com). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: AZ, WI.
what was checked ↗
· checked 2026-10-20
About RF Induction Catheter Tip Forming & Taper Shaping (Engineering Primer & Selection Guide)Expand ↓
Navigating sharp, square-cut plastic tube ends through delicate blood vessels or heart valves can dissect arterial walls and cause fatal internal hemorrhaging.
High-Frequency Electromagnetic Induction Heating
RF tipping machines use high-frequency electromagnetic fields (300 kHz to 1 MHz) to heat custom metal dies without open flames or radiant heating elements. An internal Teflon-coated mandrel supports the catheter inner lumen, preserving the guidewire channel geometry.
As the polymer tip enters the heated die cavity, it softens instantaneously and conforms to the mirror-polished spherical radius. Water chillers quench the die within milliseconds, locking in an ultra-smooth, atraumatic bullet nose that tracks effortlessly through tortuous anatomy.
High-precision automated cleanroom adhesive bonding using non-contact piezo jetting valves, positive displacement pumps, and high-intensity narrow-band LED UV curing systems. Dispenses sub-nanoliter droplets of ISO 10993 biocompatible light-cure acrylics and epoxies onto catheter hub joints, needle-to-cannula junctions, and miniature endoscopic optics, curing in 1 to 3 seconds with zero heat distortion.
Governing Consensus Standards
ISO 10993-5 — Biocompatibility of cured adhesive joints ISO 594-2 / ISO 80369-7 — Luer connector adhesive tensile pull and burst integrity ASTM D1002 — Lap shear bond strength
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT.
what was checked ↗
· checked 2026-10-20
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CT, DE.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: CA.
what was checked ↗
· checked 2026-10-20
About Automated Micro-Dispensing & UV Cure Adhesive Assembly (Engineering Primer & Selection Guide)Expand ↓
Manual syringe gluing of catheter hubs leads to messy adhesive overflow that clogs fluid channels, or starved bonds that leak blood and disconnect during high-pressure contrast injections.
Piezo Jetting and Cold Photopolymerization
Non-contact piezo jetting valves fly over the assembly at speeds up to 1,000 mm/sec, shooting precise 0.5-nanoliter droplets of UV adhesive through the air into deep recessed joints without touching delicate parts.
High-output 365 nm or 405 nm UV LED light heads instantly trigger photoinitiator molecules in the adhesive, forming crosslinked polymer chains in less than 3 seconds. The cold LED light emits zero infrared radiation, preventing heat warping of thin plastic catheter walls.
Inline Cleanroom Heavy-Gauge Medical Tray Thermoforming (ISO 11607)
Cleanroom design, tooling, and continuous thermoforming of rigid sterile barrier blister packaging, implant carrier trays, and surgical procedure kit organizers under ISO 11607. Utilizes medical grade heavy-gauge PETG (Eastar 6763), Polycarbonate, and High-Impact Polystyrene (HIPS) with continuous in-line web cleaning, particulate air ionizers, and optical vision inspection.
Governing Consensus Standards
ISO 11607-1 — Rigid barrier material selection and biocompatibility ASTM F88 — Tyvek lid heat seal peel strength USP <661.1> — Extractables and chemical suitability of packaging polymers
Typical Deliverables
First Article Inspection (FAI) dimensional reports with 3D optical scanning overlay
Seal flange flatness profilometry verifying continuous perimeter contact for Tyvek sealing
Material test certificate conforming to USP <661> and ISO 10993 cytotoxicity standards
Validated cleanroom tray cleanliness certificate with subvisible particulate counts
⇌
Off-the-shelf component cross-over:
Need Tyvek lidding, die-cut foam inserts, or heat-seal pouches?
✓Site states ISO 13485 certification— found“Quality Commitment with ISO 13485 Certification for Phoenix” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as Nelipak Healthcare Packaging: FEI 3005581234; Contract Manufacturer; Clara, Offaly, IE · FDA record ↗ · site named on company’s own page ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IN.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 9001, 13485, 14001” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: WI, SG.
what was checked ↗
· checked 2026-10-20
About Inline Cleanroom Heavy-Gauge Medical Tray Thermoforming (ISO 11607) (Engineering Primer & Selection Guide)Expand ↓
Heavy orthopedic joint implants and sharp surgical power tools will easily puncture soft packaging pouches during handling, destroying sterility and exposing patients to hospital infections.
Rigid Barrier Geometry and Seal Flange Flatness
Rigid medical trays thermoformed from durable 0.030" to 0.050" thick PETG plastic provide mechanical support that prevents sharp orthopedic tips from shifting or abrading through packaging walls.
Precision aluminum molds CNC-machined with cooling channels maintain tight dimensional tolerances across the perimeter sealing flange. Flange flatness within ±0.005 inches ensures uniform temperature and pressure distribution when heat-sealing breathable Tyvek lidding, guaranteeing a 100% continuous microbial barrier.
High-throughput precision deflashing and deburring of molded or machined medical polymer and elastomer components (e.g., PEEK spinal implants, silicone check valves, fluoroelastomer O-rings). Chills parts in liquid nitrogen vapor (-130°C to -195°C) to freeze and embrittle ultra-thin flash lines while leaving part cores ductile, then tumbles parts under high-speed non-abrasive polycarbonate micro-media blasting to fracture off burrs without altering critical dimensions.
Governing Consensus Standards
ISO 13485 — Post-molding finishing process control ASTM F2847 — Blasting media particulate residue quantification ISO 14644-1 — Post-deburring particulate cleanliness
Typical Deliverables
High-magnification optical comparator before/after deburring inspection records
Optical profilometry surface roughness (Ra) certification confirming zero core ablation
Ultrasonic post-clean solvent extract particulate verification report per USP <788>
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA.
what was checked ↗
· checked 2026-10-20
Option 3Cryogenic Systems Equipment (CSE)
cryogenicsystems.comWebsite did not answer as this company on 2026-10-20
📍 South Plainfield, NJ
Cryogenic deflashing equipment, contract deburring of molded rubber and medical plastics
✗Website answers— no answerThe listed website did not return this company’s own page on the check date. (domain does not resolve (DNS)) cryogenicsystems.com, not linked · checked 2026-10-20
–Site says it serves medical devices— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (domain does not resolve (DNS)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ.
what was checked ↗
· checked 2026-10-20
About Cryogenic Liquid Nitrogen Deflashing & Deburring (Engineering Primer & Selection Guide)Expand ↓
Microscopic plastic burrs left behind on molded spinal implants or surgical scissors can detach in the surgical wound bed, sparking foreign body granulomas and infection.
Differential Thermal Mass Embrittlement
Manual blade deburring under a microscope is tedious, slow, and risks gouging critical implant threads. Cryogenic deburring takes advantage of thermal physics: razor-thin mold flash (0.001" to 0.005" thick) has near-zero thermal mass and freezes instantly at -150°C, becoming glass-brittle.
Meanwhile, the thicker implant core retains enough heat to stay flexible and tough. When bombarded with cubic polycarbonate micro-beads traveling at 50 mph, the brittle flash snaps off cleanly at the parting line, leaving the underlying part pristine and burr-free.
High-temperature thermal sterilization and depyrogenation utilizing continuous convection tunnels or dry heat static ovens operating between 220°C and 300°C. Completely incinerates thermally resistant bacterial endotoxins (lipopolysaccharides from Gram-negative bacteria) and destroys all microbial spore forms on glass vials, surgical stainless steel trays, and metallic implants under ISO 20857 and USP <1211>.
Governing Consensus Standards
ISO 20857 — Validation of dry heat sterilization processes USP <1211> — Thermal depyrogenation cycles and biological indicators USP <85> — LAL and rFC endotoxin quantification (< 0.25 EU/mL)
✓Site says it serves medical devices— found“you face in the medical device industry.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “depyrogen…” or “dry heat”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “ISO 9001 and ISO 13485 compliant quality system,”, not counted (qualified: "compliant").
what was checked ↗
· checked 2026-10-20
✓FDA establishment registration— foundRegistered as STERIS CORPORATION: FEI 1527821; Specification Developer; Mentor, OH · FDA record ↗ · checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: NJ, SE.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“advisory services for MedTech and pharmaceutical companies.” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “depyrogen…” or “dry heat”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
About Dry Heat Sterilization & Glass Vial Depyrogenation (ISO 20857 / USP <1211>) (Engineering Primer & Selection Guide)Expand ↓
Autoclaving kills bacteria, but fragments of dead Gram-negative bacterial outer cell walls—known as endotoxins or pyrogens—survive standard steam cycles and cause severe septic fever shock if introduced into patient circulation.
Molecular Thermal Degradation
Endotoxins are exceptionally heat-stable lipopolysaccharides that require prolonged temperatures exceeding 250°C to achieve molecular incineration. Continuous depyrogenation tunnels blow laminar HEPA-filtered air heated to 300°C across inverted glass vials.
The intense thermal energy denatures the lipid-A toxic moiety. Validation protocols inoculate test vials with over 10,000 Endotoxin Units (EU) of purified E. coli endotoxin, demonstrating a minimum 3-log (99.9%) reduction via LAL assay after passing through the cooling zone.
Key Focus: Nitrogen dioxide (NO2) sterilization, room temperature 10°C–30°C, zero vacuum stress, low cytotoxicity
Rapid room-temperature, low-vacuum gaseous sterilization technology utilizing nitrogen dioxide (NO2) gas under ISO 14937. Delivers 6-log microbial lethality at mild ambient temperatures (10°C–30°C) and minimal vacuum pressures, preventing degradation of heat-sensitive drug coatings, prefilled biologics, fragile electronics, and delicate polymer optical assemblies.
Governing Consensus Standards
ISO 14937 — Validation of novel gaseous sterilizing agents ISO 10993-7 — Principles of chemical sterilant residue limits USP <71> — Membrane filtration sterility test verification
Typical Deliverables
Full ISO 14937 sterilization validation protocol and final master report (fractional / overkill)
Sub-ppm chemical gas residue clearance certificate showing negligible residual nitrates
✓Site says it serves medical devices— found“services to the medical device, biotech, pharmaceutical,” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “nitrogen dioxide” or “no2”.
what was checked ↗
· checked 2026-10-20
✓Site states ISO 13485 certification— found“SteriTek is an ISO 13485 certified, FDA registered,” · source ↗ · checked 2026-10-20
✓FDA establishment registration— foundRegistered as STERI-TEK, LLC: FEI 3024987432; Contract Sterilizer; Lewisville, TX · FDA record ↗ · checked 2026-10-20
✓Site states ISO 13485 certification— found“ISO 13485:2016 certified” · source ↗ · checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MD.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“access to safe medical devices and encourage” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “nitrogen dioxide” or “no2”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. Closest wording found: “registered to the ISO 13485 Quality Standards, and”, not counted (qualified: "adheres").
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH.
what was checked ↗
· checked 2026-10-20
About Room-Temperature Nitrogen Dioxide (NO2) Sterilization (Engineering Primer & Selection Guide)Expand ↓
Sterilizing prefilled biologic drug syringes with ethylene oxide risks explosive gas toxicity and high heat, while gamma radiation fragments protein molecules and discolors plastics.
True Ambient-Temperature Microbial Lethality
Nitrogen dioxide sterilizes entirely at room temperature (typically 21°C) and requires only mild vacuum (near atmospheric pressure). NO2 gas penetrates Tyvek packaging easily, causing rapid single-strand DNA breaks in bacterial spores via direct oxidative degradation.
Because NO2 boils at 21°C, it clears from packaging and polymers during a brief vacuum aeration cycle without lingering toxic residues. It allows pharmaceutical developers to sterilize the outside of prefilled glass syringes without heating or denaturing the sensitive biologic medicine inside.
USP <71> Sterility Testing by Closed-System Membrane Filtration
Regulatory release sterility testing under USP <71>, Ph. Eur. 2.6.1, and JP 4.06 using closed-system membrane filtration units. Filters dissolved or rinsed device extracts through dual 0.45 µm hydrophilic membrane canisters, dividing fluid equally into Fluid Thioglycollate Medium (FTM, incubated at 32.5°C for anaerobes/aerobes) and Soybean-Casein Digest Medium (TSB, incubated at 22.5°C for fungi/molds) for 14 days with zero false-positive contamination risks.
Governing Consensus Standards
USP <71> — Membrane filtration method, culture media, incubation times, and suitability testing ISO 11737-2 — Sterility testing for validation studies EP 2.6.1 — Harmonized compendial sterility criteria
Typical Deliverables
USP <71> certified Certificate of Analysis (CoA) documenting 14-day incubation results (no growth)
Method suitability test (Bacteriostasis and Fungistasis / B&F) validation report
Continuous daily visual incubation inspection logs for turbidity and fungal pellicles
Environmental cleanroom control negative testing documentation matching the test session
⇌
Off-the-shelf component cross-over:
Need sterile fluid lines, luers, or sample collection bags?
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: UT.
what was checked ↗
· checked 2026-10-20
✓Site says it serves medical devices— found“pharmaceutical, biotech and medical device industries worldwide” · source ↗ · checked 2026-10-20
✗Site names this capability— not foundinformation only, not scoredThis category’s capability terms were not all found on the pages read. Looked for: “sterility test…” or “usp <71>” or “usp 71” or “membrane filtration”.
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MN.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 403). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 403)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, SC.
what was checked ↗
· checked 2026-10-20
About USP <71> Sterility Testing by Closed-System Membrane Filtration (Engineering Primer & Selection Guide)Expand ↓
A false positive in sterility testing forces an immediate quarantine of the manufacturing facility, invalidates millions of dollars of inventory, and triggers month-long FDA warning letter investigations.
Closed Canisters and 14-Day Dual Incubation
Traditional open funnel filtration exposes wet membranes to room air during filter transfers, creating frequent environmental contamination. Modern USP <71> testing uses closed, pre-sterilized dual canister assemblies (such as the Millipore Steritest system).
Peristaltic pumps circulate device extraction fluid through both canisters simultaneously. After rinsing to remove any bacteriostatic preservatives, growth media is pumped directly into the sealed containers inside a Grade A barrier isolator. Fourteen days of incubation at two temperatures proves definitive absence of viable bacteria, yeasts, and molds.
ISO 15415 / ISO 15416 UDI Barcode Print Quality Grading & Verification
Key Focus: ISO 15415 2D DataMatrix verification, ISO 15416 1D barcode grading, Grade A/B compliance, FDA UDI rule
Optoelectronic print quality grading and data syntax verification of Unique Device Identification (UDI) barcodes on medical device pouches, cartons, and directly marked titanium implants. Implements calibrated optical verifiers conforming to ISO/IEC 15415 (2D DataMatrix / QR) and ISO/IEC 15416 (1D GS1-128), grading contrast, modulation, axial non-uniformity, and print growth to guarantee Grade A or B compliance before distribution.
Governing Consensus Standards
ISO/IEC 15415 — 2D symbol grading parameters ISO/IEC 15416 — 1D barcode reflectance and edge contrast grading FDA 21 CFR 830 — Mandatory UDI label format, DI/PI syntax, and GUDID submission
Typical Deliverables
ISO/IEC 15415 / 15416 barcode verification report with overall letter grade (A, B, C, D, F)
✗Site says it serves medical devices— not foundNo statement that it serves medical devices or medical device makers was found on the pages read. (no medical-market phrase in page body on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗Site states ISO 13485 certification— not foundNo statement of current ISO 13485 certification was found on the pages read. “Working toward” or “planned” does not count. (no ISO 13485 mention on 10 pages read)
what was checked ↗
· checked 2026-10-20
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: OH, GB.
what was checked ↗
· checked 2026-10-20
–Site says it serves medical devices— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedno readable page text (content needs JavaScript). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: IL, WA.
what was checked ↗
· checked 2026-10-20
–Website answers— not checkedblocked automated access (HTTP 429). Could not be checked, so it counts neither way.
–Site says it serves medical devices— not checkedsite not read (blocked automated access (HTTP 429)). Could not be checked, so it counts neither way.
–Site names this capability— not checkedinformation only, not scoredsite not read (blocked automated access (HTTP 429)). Could not be checked, so it counts neither way.
–Site states ISO 13485 certification— not checkedsite not read (blocked automated access (HTTP 429)). Could not be checked, so it counts neither way.
✗FDA establishment registration— not foundNo active openFDA registration matched this listing by name and location. That is common and expected for component makers, which are generally exempt (21 CFR 807.65(a)), and it says nothing about sites elsewhere. Locations searched: MA, WI.
what was checked ↗
· checked 2026-10-20
About ISO 15415 / ISO 15416 UDI Barcode Print Quality Grading & Verification (Engineering Primer & Selection Guide)Expand ↓
If a barcode scanner in a hospital emergency operating room fails to read a device label, nurses cannot record the implant serial number into electronic medical records, risking patient safety and causing massive regulatory recalls.
Mathematical Optical Grading vs. Simple Scanners
A common misconception is that if a smartphone or warehouse scanner beeps, the barcode is good. However, commercial scanners employ aggressive error-correction algorithms that mask deteriorating print heads, ink spread, or low contrast.
Calibrated ISO verifiers measure physical light reflectance at specific wavelengths and angles. They grade ten individual optical parameters—including modulation, axial non-uniformity, and minimum edge contrast—assigning a quantitative grade from 4.0 (A) to 0.0 (F). Verifying Grade A or B ensures that every hospital scanner worldwide reads the UDI on the first pass.
About the 10X Sourcing Ecosystem
The 10X MedTech sourcing platform connects device concepts to physical production across two companion open engineering catalogs:
Component Atlas: Off-the-shelf raw materials, extruded tubing, markers, balloons, and geometric construction drawings for medical device R&D.
Service Atlas (This Directory): Specialized contract development, prototyping, CNC machining, laser cutting, medical coatings, IEC 60601-1 safety, cleanroom CDMO, and medical sterilization.
Vendor Contact & RFQ Formulator: Engineering tool to formulate unambiguous RFQ inquiries with attached CAD specs, GD&T requirements, and ISO 13485 deliverables.