FDA product code · Radiology · Class 2

MOS: Coil, Magnetic Resonance, Specialty

MOS is FDA's product code for "Coil, Magnetic Resonance, Specialty": a Class 2 device classified under 21 CFR 892.1000, reviewed by the Radiology panel.

510(k) review time for MOS

Across 65 510(k) clearances under MOS decided from 2018-01-01 to 2026-10-06, the median was 57 days from FDA receipt to decision. Half took between 27 and 119 days, and 80% were decided within 182 days. These are past clearances, not a forecast for a new submission.

Days from FDA receipt to 510(k) decision, MOS, decisions 2018-01-01 to 2026-10-06 (n = 65)
Fastest14
25th percentile27
Median57
75th percentile119
80th percentile182
90th percentile249
Slowest522
Median days by decision year, MOS (years with enough clearances to compute). The partial final year counts only submissions already decided, so its median runs low.
YearMedian daysn
20183010
2020515
20227911
20235910
20243910
2026 (to 10-06, partial)319

Source: openFDA 510(k) records, snapshot of 2026-10-06 (openFDA data as of 2026-09-28). Compare 510(k) review times across all device types, see every code side by side in the Clearance Timeline Estimator, or browse the clearances themselves in PredicateScope.

MOS in the public FDA record

Records naming MOS, from openFDA (snapshot of 2026-09-15)
510(k) clearances, all years490
Device recalls38
Establishment listings810
GUDID device identifiers1,965

Counts of records, not of devices or events. Adverse event reports for MOS are in MAUDEScope, as counts with the query shown: MAUDE has no denominator, so a report count is not a rate and does not show that a device caused an event.

FDA-recognized standards that cite MOS

14 FDA recognized consensus standards cite MOS, among them NEMA MS 3-2008 (R2020); NEMA MS-1-2008 (R2020); NEMA MS 6-2008 (R2014 R2020). Horizontal standards such as biocompatibility, sterilization and software standards can apply without citing the code.

  • 12-187 NEMA MS 3-2008 (R2020) — Determination of Image Uniformity in Diagnostic Magnetic Resonance Images
  • 12-188 NEMA MS-1-2008 (R2020) — Determination of Signal-to-Noise Ratio (SNR) in Diagnostic Magnetic Resonance Imaging
  • 12-195 NEMA MS 6-2008 (R2014 R2020) — Determination of Signal-to-Noise Ratio and Image Uniformity for Single-Channel Non-Volume Coils in Diagnostic MR Imaging
  • 12-196 NEMA MS 2-2008 (R2020) — Determination of Two-Dimensional Geometric Distortion in Diagnostic Magnetic Resonance Images
  • 12-264 NEMA MS 11-2010 — Determination of Gradient-Induced Electric Fields in Diagnostic Magnetic Resonance Imaging
  • 12-288 NEMA MS 9-2008 (R2020) — Standards Publication Characterization of Phased Array Coils for Diagnostic Magnetic Resonance Images
  • 12-298 NEMA MS 10-2010 — Determination of Local Specific Absorption Rate (SAR) in Diagnostic Magnetic Resonance Imaging
  • 12-306 NEMA MS 12-2016 — Quantification and Mapping of Geometric Distortion for Special Applications
  • 12-315 NEMA MS 8-2016 (R2003) — Characterization of the Specific Absorption Rate (SAR) for Magnetic Resonance Imaging Systems
  • 12-322 NEMA MS 5-2018 — Determination of Slice Thickness in Diagnostic Magnetic Resonance Imaging
  • 12-331 NEMA Standards Publication MS 14-2019 — Characterization of Radiofrequency (RF) Coil Heating in Magnetic Resonance Imaging Systems
  • 12-332 IEC 62464-1 Edition 2.0 2018-12 — Magnetic resonance equipment for medical imaging Part 1: Determination of essential image quality parameters.
  • 12-347 IEC 60601-2-33 Edition 4.0 2022-08 — Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and essential performance of magnetic resonance equipment for medical diagnosis
  • 12-354 NEMA MS 4-2023 — Acoustic Noise Measurement Procedure for Diagnosing Magnetic Resonance Imaging Devices

Source: FDA Recognized Consensus Standards, snapshot of 2026-09-01. Search them all in the Consensus Standards Lookup.